Felicity IVEM8048-LV Error Codes: Causes & Fixes (47 codes)

This is the complete fault table for the Felicity IVEM8048-LV Inverter family — 47 codes shared by 2 model numbers, transcribed from the official manual. On Felicity units, a fault code means the unit has cut its output and the red LED stays solid; a warning flashes the red LED while the unit keeps running.

Also coversIVEM8048

Last checked against the official manuals on July 10, 2026.

How to read the severity labels

  • Fault(39)output stops · red LED solid
  • Warning(8)unit keeps running · red LED flashing

Fault codes (39)output stops · red LED solid

F01Fault

Bus voltage is too high.

Fault

CauseAC Surge or internal components failed.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

F02Fault

Bus voltage is too low.

Fault

CauseThe internal DC bus voltage fell below its operating range while running. The bus is regulated entirely inside the unit, so a persistent low reading points to an internal conversion-stage fault rather than external wiring.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

F03Fault

Bus soft start fail.

Fault

CauseInternal components failed.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

F04Fault

Inverter soft start fail.

Fault

CauseInternal components failed.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

F05Fault

Over current or surge detected by Software.

Fault

CauseThe control software measured a current or surge on the power stage beyond its protection limit and shut down. The software trip catches sustained overcurrent, as opposed to the instantaneous hardware trip of F06.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

F06Fault

Over current or surge detected by hardware.

Fault

CauseA hardware protection circuit tripped on overcurrent or surge at the power stage. This comparator acts independently of the firmware and reacts to fast transients such as inrush or an AC surge.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

F07Fault

Output voltage is too low.

Fault

CauseConnected load is too high or internal failure.

Recommended fixReduce the connected load. Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F08Fault

Output voltage is too high.

Fault

CauseInternal failure causing high output voltage.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F09Fault

Output short circuited.

Fault

CauseWiring not connected well or abnormal load.

Recommended fixCheck if wiring is connected well and remove abnormal load.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F10Fault

Overload time out.

Fault

CauseConnected load exceeds inverter capacity for an extended time.

Recommended fixReduce the connected load by switching off some equipment.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F11Fault

Battery voltage is too high.

Fault

CauseBattery spec or quantity does not meet requirements.

Recommended fixCheck if spec and quantity of batteries are meet requirements.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F12Fault

Over current happen at DC/DC circuit.

Fault

CauseThe DC/DC converter stage between the battery and the internal bus drew more current than its protection limit allows.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F13Fault

PV voltage is too high.

Fault

CauseToo many PV modules in series.

Recommended fixReduce the number of PV modules in series.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F14Fault

Short circuited happen at PV port.

Fault

CauseWiring not connected well.

Recommended fixCheck if wiring is connected well.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F15Fault

PV power is abnormal.

Fault

CauseExcessive PV power input.

Recommended fixReduce the number of PV modules.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F16Fault

Over current happen at PV port.

Fault

CauseCurrent flowing in from the PV array exceeded the charge stage's protection limit.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F17Fault

Fan is locked.

Fault

CauseFan wiring problem or fan failure.

Recommended fixCheck if wiring is connected well. Replace the fan.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F18Fault

Over temperature happen at PV circuit.

Fault

CauseThe temperature of internal PV component is over the limitation.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F19Fault

Over temperature happen at Convert L circuit.

Fault

CauseThe temperature of Convert L battery converter component is over the limitation.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F20Fault

Over temperature happen at INV circuit.

Fault

CauseThe temperature of internal INV component is over the limitation.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F21Fault

The inner temperature over.

Fault

CauseThe inner temperature is over the limitation.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F22Fault

DCDC current sensor failed.

Fault

CauseThe DC/DC current sensor returned an out-of-range or implausible reading, so the control board can no longer trust that stage's current measurement.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F23Fault

No.2 DCDC current sensor failed.

Fault

CauseThe second DC/DC current sensor returned an out-of-range or implausible reading, so the control board can no longer trust that channel's current measurement.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F24Fault

Inverter current sensor failed.

Fault

CauseThe inverter-stage current sensor returned an out-of-range or implausible reading, so the control board can no longer trust its inverter current measurement.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F25Fault

OP current sensor failed.

Fault

CauseThe output current sensor returned an out-of-range or implausible reading, so the control board can no longer trust its output-current measurement.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F26Fault

Sharing current sensor failed.

Fault

CauseThe current-sharing sensor used to balance paralleled units returned an out-of-range or implausible reading, so the inverter can no longer verify how load current is being shared.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 38

F27Fault

The AC input and output wires are inversely connected.

Fault

CauseAC input and output wiring reversed, possibly during parallel installation.

Recommended fix1. Please check AC input and output wires are connected correctly. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please funish parallel installation first, and then restart inverters. 3. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F28Fault

Single unit is installed to parallel system.

Fault

CauseSingle unit configured into a parallel system, or wiring problem during parallel installation.

Recommended fix1. Please check if single unit is installed to parallel system. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please funish parallel installation first, and then restart inverters. 3. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F29Fault

DC/DC soft start fail.

Fault

CauseThe DC/DC converter failed to ramp up to its working voltage during soft start, which indicates an internal component fault rather than a wiring problem.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F31Fault

Over temperature happen at convert H circuit.

Fault

CauseThe temperature of internal convert H component is over the limitation.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F32Fault

Over temperature happen at LLC TX.

Fault

CauseThe temperature of internal DC/DC TX is over the limitation.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F33Fault

Over current happen at LLC circuit.

Fault

CauseThe LLC resonant converter (the isolated DC link inside the unit) drew current above its protection limit.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F40Fault

CAN data loss.

Fault

CauseCommunication failure between paralleled inverters.

Recommended fix1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F41Fault

Host data loss.

Fault

CauseCommunication failure between paralleled inverters.

Recommended fix1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F42Fault

Synchronization data loss.

Fault

CauseCommunication failure between paralleled inverters.

Recommended fix1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F43Fault

Current feedback into the inverter is detected.

Fault

CauseReverse-connected L/N cables, or sharing cables not connected/connected across phases in three-phase setup.

Recommended fix1. Restart the inverter. 2. Check if L/N cables are not connected reversely in all inverters. 3. For parallel system in single phase, make sure the sharing cables are connected in all inverters. For supporting three-phase system, make sure the sharing cables are connected in the inverters in the same phase, and disconnected in the inverters in different phases. 4. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F44Fault

The firmware version of each inverter is not the same.

Fault

CauseMismatched firmware versions across paralleled inverters.

Recommended fix1. Update all inverter firmware to the same version. 2. Check the version of each inverter via LCD setting and make sure the CPU versions are same. if not, please contact your installer to provide the firmware to update. 3. After updating, if the problem still remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F45Fault

The output current of each inverter is different.

Fault

CauseSharing cable connection issue between paralleled inverters.

Recommended fix1. Check if sharing cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

F46Fault

AC output mode setting is different.

Fault

CauseInconsistent AC output mode (program 28) settings across inverters.

Recommended fix1. Switch off the inverter and check LCD setting program 28. 2. For parallel system in single phase, make sure no 3P1, 3P2 or 3P3 is set on program 28. For supporting three-phase system, make sure no "PAL" is set on program 28. 3. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 39

Warning codes (8)unit keeps running · red LED flashing

W01Warning

Fan is locked.

Warning

Warning: Fan is locked. Beep three times every second.

CauseFan wiring not connected well or fan failure.

Recommended fixCheck if the Fan's wiring connected well. Replace the fan.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

W02Warning

Overload.

Warning

Warning: Overload. Beep twice every second.

CauseConnected load exceeds the inverter capacity.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

W03Warning

Low battery.

Warning

Warning: Low battery. Beep once every second.

CauseThe battery voltage is too low.

Recommended fixIt should be charging.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

W50Warning

BMS firmware version is not matched.

Warning

CauseBMS firmware version mismatch.

Recommended fixUpgrade the firmware of BMS.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

W51Warning

BMS doesn't allow inverter to charge battery.

Warning

CauseBMS has blocked charging.

Recommended fixInverter will stop charging battery automatically.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

W52Warning

BMS doesn't allow inverter to discharge battery.

Warning

CauseBMS has blocked discharging.

Recommended fixInverter will stop discharging battery automatically.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

W53Warning

BMS require inverter to charge battery.

Warning

CauseBMS has requested charging.

Recommended fixInverter will charge battery automatically.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

W54~65Warning

BMS detect something wrongs happened.

Warning

BMS detect something wrongs happened (range of codes 54 through 65).

CauseBMS has detected an internal fault.

Recommended fixIf the code is keeping for long time, please contact with your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf· page 37

Still seeing a code on your IVEM8048-LV?

Send us the code on your screen and a Felicity technician will reply with the exact steps for your unit. Support is free for life — a first diagnosis never needs a callout.

Keep troubleshooting

Related devices

Common questions about IVEM8048-LV error codes

What is the difference between a fault and a warning on the IVEM8048-LV?
A fault cuts the unit's output and the red LED stays solid — this page lists 39 of them for the IVEM8048-LV. A warning only flashes the red LED and the unit keeps running; there are 8 warning codes here. Resolve the cause of a fault before restarting; warnings can usually be cleared while the unit runs.
Which model numbers does this page cover?
The IVEM8048-LV shares its firmware and fault table with 1 other model number: IVEM8048. If your unit is any of these, every code on this page applies to it.
Where do these codes come from?
Every entry was transcribed from FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf — Felicity's official documentation. Each row cites its source manual (and page where printed), so you can verify the wording before acting on it.

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.