25Fault

Felicity inverter error 25 (F25)

Inverter hardware current too large

Also displayed as F25 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

IVCM1012 PRO

InverterFault

Also applies to:IVCM2024 PROIVCM3024 PRO

What it means

Inverter hardware current too largeThe inverter hardware current is too large.

Cause: The hardware over-current protection on the inverter stage tripped: a sudden current spike beyond the hardware limit, typically a load surge or an output fault.

How to fix it

Reduce the connected load by switching off some equipment.

Source: ICM.pdf, p.14

IVGM5KL-P1G1

InverterFault

Also applies to:IVGM6KL-P1G1IVGM7K6L-P1G1IVGM8KL-P1G1

What it means

Battery over voltage faultBattery voltage exceeds specification.

Cause: The voltage at the battery terminals exceeds the inverter's specified battery range — usually a pack whose configuration or specification does not match the inverter, or a charge source pushing the pack too high.

How to fix it

  1. Check the Battery voltage is in the range of standard voltage in specification
  2. Check whether Battery cables are firmly and correctly connected
  3. Seek help from us, if can not go back to normal state.

Source: Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf, p.53

T-REX-3KLP1G01

InverterFault

Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01T-REX-10KLP3G01

What it means

Hardware detect over current at inverter port

Cause: A hardware protection circuit tripped on overcurrent at the inverter port. It acts independently of the firmware and reacts to fast transients such as load inrush or a surge.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.37 · T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.38 · T-REX-10KLP3G01-Inverter-User-Guide.pdf, p.28

IVEM 6048

InverterFault

Also applies to:IVEM6048

What it means

OP current sensor failed

Cause: Output current sensor hardware failure.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.37

IVEM8048-II

InverterFault

Also applies to:IVEM12048-IIIVEM 8K-12K Series II

What it means

OP current sensor failed

Cause: Output current sensor failure.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: IVEM8K-12K-II_compressed.pdf, p.44

IVEM8048-LV

InverterFault

Also applies to:IVEM8048

What it means

OP current sensor failed

Cause: The output current sensor returned an out-of-range or implausible reading, so the control board can no longer trust its output-current measurement.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.38

T-REX-10KHP3G01

InverterCritical

What it means

Hardware detect over current at inverter portHardware-level over current detection at inverter port.

Cause: A hardware protection circuit tripped on overcurrent at the inverter port. It acts independently of the firmware and reacts to fast transients such as load inrush or a surge.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: T-REX-10KHP3G01-Inverter-User-Guide.pdf, p.28

T-REX-50KHP3G01

InverterFault

What it means

Battery 2 reverse connection faultBattery 2 positive and negative poles is reversed, check the battery wiring.

Cause: Battery 2 is connected with positive and negative poles reversed, so the battery stage blocks it until the wiring is corrected.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.46

Apollo-5KLP1G01-MX

Energy storage systemCritical

Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2

What it means

Hardware detect over current at inverter portHardware detected over current at inverter port.

Cause: Hardware detect over current at inverter port.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.43

Frequently asked questions

What does error 25 mean on a Felicity inverter?
It depends on the model — 10 devices use code 25. On the IVCM1012 PRO it means: Inverter hardware current too large. The card for each model on this page gives its exact meaning and fix.
Is error 25 a fault or a warning?
25 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 25?
Reduce the connected load by switching off some equipment. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.