22Fault

Felicity inverter error 22 (F22)

Inv soft start timeout

Also displayed as F22 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

IVPS/IVPM Series

InverterFault

Also applies to:IVPS2512IVPS2524IVPS3524IVPS5024IVPS5048IVPS7548IVPS-7548IVPS10048+9

What it means

Inv soft start timeoutThe inverter soft start did not complete in time.

Cause: At power-up the soft-start ramp failed to bring the inverter stage to its working point within the allowed time — an internal power-stage or pre-charge fault.

How to fix it

Contact the repair center.

Source: IVPS-IVPM User Guide.pdf, p.17 · IVPS3524P1G1-LV IVPS5048P1G1-LV IVPS7548P2G1 IVPS10048P2G1 User Guide - EN.pdf, p.24

IVCM1012 PRO

InverterFault

Also applies to:IVCM2024 PROIVCM3024 PRO

What it means

Output voltage too lowOutput voltage is too low.

Cause: The AC output voltage sagged below the allowed range, most often because a heavy load is dragging the output down, otherwise an internal voltage-regulation fault.

How to fix it

  1. Reduce the connected load.
  2. Restart the unit, if the error persists, contact the repair center.

Source: ICM.pdf, p.14

IVGM5KL-P1G1

InverterFault

Also applies to:IVGM6KL-P1G1IVGM7K6L-P1G1IVGM8KL-P1G1

What it means

Battery Under Voltage Alarm or Battery SOC Low AlarmBattery voltage is too low or Battery SOC is too low, the battery should be charged.

Cause: Either the measured battery voltage or the reported state of charge has fallen to the low-battery threshold — the pack is close to empty and must be recharged.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf, p.51

T-REX-3KLP1G01

InverterFault

Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01

What it means

Output voltage is too low

Cause: The AC output voltage sagged below the permitted range — usually the connected load exceeds what the inverter can hold voltage into.

How to fix it

Reduce the connected load.

Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.38

IVEM 6048

InverterFault

Also applies to:IVEM6048

What it means

DCDC current sensor failed

Cause: DC/DC current sensor hardware failure.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.37

IVEM8048-II

InverterFault

Also applies to:IVEM12048-IIIVEM 8K-12K Series II

What it means

DCDC current sensor failed

Cause: DCDC current sensor failure.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: IVEM8K-12K-II_compressed.pdf, p.44

IVEM8048-LV

InverterFault

Also applies to:IVEM8048

What it means

DCDC current sensor failed

Cause: The DC/DC current sensor returned an out-of-range or implausible reading, so the control board can no longer trust that stage's current measurement.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.38

T-REX-10KHP3G01

InverterFault

Also applies to:T-REX-10KLP3G01

What it means

Output voltage is too low

Cause: Connected load is too high.

How to fix it

Reduce the connected load.

Source: T-REX-10KHP3G01-Inverter-User-Guide.pdf, p.28 · T-REX-10KLP3G01-Inverter-User-Guide.pdf, p.28

T-REX-50KHP3G01

InverterFault

What it means

Battery 1 overcurrent faultBattery 1 current is too large, check the battery charge and discharge power.

Cause: Battery 1 current tripped the hardware overcurrent protection, which acts independently of the firmware — a fast surge in charge or discharge current on that channel.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.46

Apollo-5KLP1G01-MX

Energy storage systemFault

Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2

What it means

Output voltage is too low

Cause: Output voltage is too low.

How to fix it

Reduce the connected load.

Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.43

LUX-S-1600LG01

BatteryFault

What it means

Batter Relay ErrorFault event: battery relay (contactor) error/failure to open or close as commanded.

Cause: Communication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.

How to fix it

  1. Restart the unit.
  2. If the error persists, contact the repair center.

Source: LUX-S-1600LG01.pdf, p.22

Frequently asked questions

What does error 22 mean on a Felicity inverter?
It depends on the model — 13 devices use code 22. On the IVPS/IVPM Series it means: Inv soft start timeout. The card for each model on this page gives its exact meaning and fix.
Is error 22 a fault or a warning?
22 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 22?
Contact the repair center. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.