05Warning

Felicity inverter error 05 (F05)

Power derating (low utility voltage)

Also displayed as F05 on some models.

Warningthe red LED flashes and the inverter keeps running. Deal with it before it escalates.

Severity differs by model — check your model below.

The exact meaning depends on your model:

IVPS/IVPM Series

InverterWarning

Also applies to:IVPS2512IVPS2524IVPS3524IVPS5024IVPS5048IVPS7548IVPS-7548IVPS10048+9

What it means

Power derating (low utility voltage)The inverter derates its output power because the utility voltage is low.

Cause: The AC input voltage is low (about 90-170V).

How to fix it

  1. Read the voltage from the screen and confirm the voltage of the AC input is about 90-170V.
  2. If it is, the AC input voltage is low and the unit can work normally.
  3. If not, contact the repair center.

Source: IVPS-IVPM User Guide.pdf, p.18 · IVPS3524P1G1-LV IVPS5048P1G1-LV IVPS7548P2G1 IVPS10048P2G1 User Guide - EN.pdf, p.27

IVCM1012 PRO

InverterFault

Also applies to:IVCM2024 PROIVCM3024 PRO

What it means

High PV voltage

Cause: The solar array voltage at the PV input is above the unit's maximum allowed input voltage, usually because too many panels are wired in series for this input.

How to fix it

  1. Please check the voltage of the solar panel, it should be less than 95V.
  2. If the voltage is ok, please contact your installer.

Source: ICM.pdf, p.13

IVGM5KL-P1G1

InverterFault

Also applies to:IVGM6KL-P1G1IVGM7K6L-P1G1IVGM8KL-P1G1

What it means

PV over current faultPV input over current fault.

Cause: A fault has been detected in the PV input stage — usually a short, ground fault, or isolation failure between the PV array and the inverter chassis. Wet connectors, damaged cable insulation, or moisture in a junction box are common causes.

How to fix it

  1. Restart the system 2~3 times
  2. If the fault still exists, please contact us for help.

Source: Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf, p.53

IVEM 6048

InverterFault

Also applies to:IVEM6048

What it means

Over current or surge detected by Software

Cause: Software-detected overcurrent or surge condition.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.36

IVEM8048-II

InverterFault

Also applies to:IVEM12048-IIIVEM 8K-12K Series II

What it means

Over current or surge detected by Software

Cause: Software-detected over current or surge condition.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: IVEM8K-12K-II_compressed.pdf, p.43

IVEM8048-LV

InverterFault

Also applies to:IVEM8048

What it means

Over current or surge detected by Software

Cause: The control software measured a current or surge on the power stage beyond its protection limit and shut down. The software trip catches sustained overcurrent, as opposed to the instantaneous hardware trip of F06.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.37

T-REX-50KHP3G01

InverterFault

What it means

PV1 overcurrent faultThe current of the PV1 is too large, check the string current.

Cause: Current from the PV1 string exceeded the input stage's protection limit — more current than that MPPT channel is rated to carry.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.45

LUX-X-96050HG01

BatteryWarning

Also applies to:LUX-X-96050HMG01LUX-X-96050HCG01

What it means

High Charging CurrentCharging current above safe limit.

Cause: Excessive charging current from inverter/charger.

How to fix it

Reduce charging current.

Source: LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf, p.21

LUX-Y-48100HG01

BatteryWarning

Also applies to:LUX-Y-48100HCG01LUX-Y-48100HMG01LUX-Y-48100HR13G01LUX-Y-48100HR9G01

What it means

High Charging CurrentCharging current exceeded the upper threshold.

Cause: Excessive charging current from the inverter or charger.

How to fix it

Reduce charging current.

Source: LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf, p.20

LUX-Y-48100HG01MN

BatteryFault

What it means

High Charging Current

Cause: Excessive charging current from the inverter or charger.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf, p.27

SCCM3024-III

Charge controllerCritical

Also applies to:SCCM4524-IIISCCM4548-IIISCCM6048-IIISCCM8048-IIISCCM10048-IIISCCM12048-III

What it means

PV is high lossSolar (PV) input voltage exceeds the controller's maximum allowable input voltage (140V or 190V depending on model).

Cause: PV array open-circuit voltage exceeds the controller's maximum solar input voltage rating (95V for 30A/45A models with 12V/24V; 145V for 45A/60A/80A 48V models; 165V for 100A/120A models).

How to fix it

  1. Please check the voltage of the solar panel, it should be less than 140V or 190V
  2. If the voltage is ok, please contact your installer.

Source: felicitysolar SCCM-III MPPT Solar Charge Controller User Guide.pdf, p.18

LUX-S-1600LG01

BatteryFault

What it means

Over charge currentFault event: battery charging current exceeded the maximum allowed value (battery max charge current 40A on LUX-S-1600LG01).

Cause: Charging current exceeded the battery's maximum allowed charge current.

How to fix it

  1. Restart the unit.
  2. If the error persists, contact the repair center.

Source: LUX-S-1600LG01.pdf, p.22

Frequently asked questions

What does error 05 mean on a Felicity inverter?
It depends on the model — 13 devices use code 05. On the IVPS/IVPM Series it means: Power derating (low utility voltage). The card for each model on this page gives its exact meaning and fix.
Is error 05 a fault or a warning?
It depends on the model: on some models 05 is a fault (output cut, red LED solid), on others a warning (red LED flashing, unit keeps running). Check the card for your model on this page.
How do I clear or fix error 05?
Read the voltage from the screen and confirm the voltage of the AC input is about 90-170V. If it is, the AC input voltage is low and the unit can work normally. The exact steps for each affected model are listed on this page.