Also applies to:IVPS2512IVPS2524IVPS3524IVPS5024IVPS5048IVPS7548IVPS-7548IVPS10048+9
What it means
TX NTC is disconnected — The transformer temperature sensor (NTC) is disconnected.
Cause: The transformer temperature sensor wiring is disconnected or the sensor failed.
How to fix it
Contact the repair center.
Source: IVPS-IVPM User Guide.pdf, p.18 · IVPS3524P1G1-LV IVPS5048P1G1-LV IVPS7548P2G1 IVPS10048P2G1 User Guide - EN.pdf, p.27
Also applies to:IVCM2024 PROIVCM3024 PRO
What it means
PV relay voltage abnormal — The PV relay voltage is abnormal.
Cause: A safety relay inside the inverter has failed self-test or is stuck. The inverter is designed to refuse grid connection in this state, so this is not an issue you can clear with restart cycles.
How to fix it
- 1Internal components failed.
- 2Restart the unit, if the error persists, contact the repair center.
Source: ICM.pdf, p.13
Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01T-REX-10KHP3G01
What it means
PV current sensor failed
Cause: The PV current sensor returned an out-of-range or implausible reading, so the control board can no longer trust its PV current measurement.
How to fix it
Restart the unit, if the error persists, contact the repair center.
Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.37 · T-REX-10KHP3G01-Inverter-User-Guide.pdf, p.28
Also applies to:IVEM6048
What it means
Over current or surge detected by hardware
Cause: Hardware-detected overcurrent or surge condition.
How to fix it
Restart the unit, if the error persists, contact the repair center.
Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.36
Also applies to:IVEM12048-IIIVEM 8K-12K Series II
What it means
Over current or surge detected by hardware
Cause: Hardware-detected over current or surge condition.
How to fix it
Restart the unit, if the error persists, contact the repair center.
Source: IVEM8K-12K-II_compressed.pdf, p.43
Also applies to:IVEM8048
What it means
Over current or surge detected by hardware
Cause: A hardware protection circuit tripped on overcurrent or surge at the power stage. This comparator acts independently of the firmware and reacts to fast transients such as inrush or an AC surge.
How to fix it
Restart the unit, if the error persists, contact the repair center.
Source: FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.37
What it means
PV2 overcurrent fault — The current of the PV2 is too large, check the string current.
Cause: Current from the PV2 string exceeded the input stage's protection limit — more current than that MPPT channel is rated to carry.
How to fix it
- 1Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
- 2If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.
Source: T-REX-50KHP3G01-user-manual-.pdf, p.45
Energy storage systemCritical Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2
What it means
PV current sensor failed
Cause: PV current sensor failed.
How to fix it
Restart the unit, if the error persists, contact the repair center.
Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.42
Also applies to:LUX-X-96050HMG01LUX-X-96050HCG01LUX-Y-48100HG01LUX-Y-48100HCG01LUX-Y-48100HMG01LUX-Y-48100HR13G01LUX-Y-48100HR9G01
What it means
High Discharging Current
Cause: Excessive load current draw from the battery.
How to fix it
Reduce discharging current.
Source: LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf, p.21 · LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf, p.20
What it means
High Discharging Current
Cause: Excessive load current draw from the battery.
How to fix it
- 1Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
- 2If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.
Source: LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf, p.27
Also applies to:SCCM4524-IIISCCM4548-IIISCCM6048-IIISCCM8048-IIISCCM10048-IIISCCM12048-III
What it means
Battery temperature is too low — Detected battery temperature is below the safe charging range.
Cause: Battery ambient temperature is too low, or remote temperature sensor (RTS) is faulty, disconnected, or reporting incorrect values.
How to fix it
- 1Check your remote temperature sensor and your battery ambient temperature
- 2If the problem remains, please contact your installer.
Source: felicitysolar SCCM-III MPPT Solar Charge Controller User Guide.pdf, p.18
What it means
Over discharge current — Fault event: battery discharge current exceeded the maximum allowed value (max discharge current 50A on LUX-S-1600LG01).
Cause: Discharge current exceeded the maximum allowed value — the connected loads are drawing more current than the battery can supply.
How to fix it
- 1Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
- 2If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.
Source: LUX-S-1600LG01.pdf, p.22