10Fault

Felicity inverter error 10 (F10)

Overload

Also displayed as F10 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

Severity differs by model — check your model below.

The exact meaning depends on your model:

IVCM1012 PRO

InverterFault

Also applies to:IVCM2024 PROIVCM3024 PRO

What it means

Overload

Cause: The connected load is drawing more power than the inverter's rated output capacity.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: ICM.pdf, p.13

T-REX-3KLP1G01

InverterFault

Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01

What it means

Abnormal LLC

Cause: The LLC resonant converter (the isolated DC link inside the unit) is operating outside its normal envelope — an internal converter fault rather than a wiring issue.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.37

IVEM 6048

InverterFault

Also applies to:IVEM6048

What it means

Overload time out

Cause: Sustained overload condition.

How to fix it

Reduce the connected load by switching off some equipment.

Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.37

IVEM8048-II

InverterFault

Also applies to:IVEM12048-IIIVEM 8K-12K Series II

What it means

Overload time out

Cause: Connected load has exceeded the inverter's overload capacity for too long.

How to fix it

Reduce the connected load by switching off some equipment.

Source: IVEM8K-12K-II_compressed.pdf, p.43

IVEM8048-LV

InverterFault

Also applies to:IVEM8048

What it means

Overload time out

Cause: Connected load exceeds inverter capacity for an extended time.

How to fix it

Reduce the connected load by switching off some equipment.

Source: FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.38

T-REX-50KHP3G01

InverterFault

What it means

PV2 reverse connection faultPv2 string positive and negative connection, check the string wiring.

Cause: The PV2 string is connected with positive and negative reversed, so the input stage blocks it until the string wiring is corrected.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.45

Apollo-5KLP1G01-MX

Energy storage systemCritical

Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2

What it means

Abnormal LLCAbnormal LLC converter operation.

Cause: The internal LLC DC-DC converter stage is operating abnormally. This is an internal power-conversion fault, not something caused by wiring or settings.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.42

LUX-S-1600LG01

BatteryFault

What it means

Cell temperature is too lowFault event: battery cell temperature fell below its low threshold.

Cause: A battery cell temperature fell below the lower protection limit — the ambient temperature is too low.

How to fix it

  1. Restart the unit.
  2. If the error persists, contact the repair center.

Source: LUX-S-1600LG01.pdf, p.22

LUX-X-96050HG01

BatteryWarning

Also applies to:LUX-X-96050HMG01LUX-X-96050HCG01

What it means

Low Cell TemperatureBattery cell temperature is below safe operating limit.

Cause: Cell too cold (ambient temperature below charge/discharge range).

How to fix it

Wait for temperature rise.

Source: LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf, p.21

LUX-Y-48100HG01

BatteryWarning

Also applies to:LUX-Y-48100HCG01LUX-Y-48100HMG01LUX-Y-48100HR13G01LUX-Y-48100HR9G01

What it means

Low Cell TemperatureCell temperature is too low.

Cause: Cell too cold — ambient temperature below the charge/discharge range.

How to fix it

Wait for temperature rise.

Source: LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf, p.20

LUX-Y-48100HG01MN

BatteryFault

What it means

Low Cell Temperature

Cause: Cell too cold — ambient temperature below the charge/discharge range.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf, p.27

Frequently asked questions

What does error 10 mean on a Felicity inverter?
It depends on the model — 11 devices use code 10. On the IVCM1012 PRO it means: Overload. The card for each model on this page gives its exact meaning and fix.
Is error 10 a fault or a warning?
It depends on the model: on some models 10 is a fault (output cut, red LED solid), on others a warning (red LED flashing, unit keeps running). Check the card for your model on this page.
How do I clear or fix error 10?
Power down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.