08Fault

Felicity inverter error 08 (F08)

Fan 1 locked

Also displayed as F08 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

Severity differs by model — check your model below.

The exact meaning depends on your model:

IVCM1012 PRO

InverterFault

Also applies to:IVCM2024 PROIVCM3024 PRO

What it means

Fan 1 lockedFan 1 is locked.

Cause: Internal cooling fan failure detected. Often caused by dust buildup, bearing wear, or debris fouling the fan blades.

How to fix it

  1. Check if the Fans wiring connected well.
  2. Replace the fan.

Source: ICM.pdf, p.13

IVEM 6048

InverterFault

Also applies to:IVEM6048IVEM8048-LVIVEM8048

What it means

Output voltage is too high

Cause: Internal failure causing high output voltage.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.37 · FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.38

IVEM8048-II

InverterFault

Also applies to:IVEM12048-IIIVEM 8K-12K Series II

What it means

Output voltage is too high

Cause: Output voltage exceeds acceptable range.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: IVEM8K-12K-II_compressed.pdf, p.43

T-REX-10KLP3G01

InverterFault

What it means

Over current happen at Battery

Cause: Current into or out of the battery exceeded the protection limit — a charge or discharge surge beyond what the battery stage is rated for.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: T-REX-10KLP3G01-Inverter-User-Guide.pdf, p.27

T-REX-50KHP3G01

InverterFault

What it means

PV4 overcurrent faultThe current of the PV3 string is too large, check the string current.

Cause: Current from the PV4 string exceeded the input stage's protection limit — more current than that MPPT channel is rated to carry.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.45

LUX-X-96050HG01

BatteryWarning

Also applies to:LUX-X-96050HMG01LUX-X-96050HCG01

What it means

Low BMS TemperatureBMS internal temperature is below safe operating limit.

Cause: BMS too cold (ambient temperature below operating range).

How to fix it

Wait for temperature rise.

Source: LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf, p.21

LUX-Y-48100HG01

BatteryWarning

Also applies to:LUX-Y-48100HCG01LUX-Y-48100HMG01LUX-Y-48100HR13G01LUX-Y-48100HR9G01

What it means

Low BMS TemperatureBMS temperature is too low.

Cause: BMS too cold — ambient temperature below the operating range.

How to fix it

Wait for temperature rise.

Source: LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf, p.20

LUX-Y-48100HG01MN

BatteryFault

What it means

Low BMS Temperature

Cause: BMS too cold — ambient temperature below the operating range.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf, p.27

SCCM3024-III

Charge controllerCritical

Also applies to:SCCM4524-IIISCCM4548-IIISCCM6048-IIISCCM8048-IIISCCM10048-IIISCCM12048-III

What it means

Battery voltage is differentDetected battery voltage does not match the configured/rated battery voltage of the system.

Cause: Battery is incorrectly wired, has wrong rated voltage configuration (12V/24V/48V), or auto-detection has failed.

How to fix it

  1. Check that the battery is properly connected or check battery rated voltage is set correctly
  2. If the problem remains, please contact your installer.

Source: felicitysolar SCCM-III MPPT Solar Charge Controller User Guide.pdf, p.18

LUX-S-1600LG01

BatteryFault

What it means

Heat sink temperature is too lowFault event: heat sink temperature below its low threshold.

Cause: The heat-sink temperature fell below its lower protection limit — the ambient temperature is too low for operation.

How to fix it

  1. Restart the unit.
  2. If the error persists, contact the repair center.

Source: LUX-S-1600LG01.pdf, p.22

Frequently asked questions

What does error 08 mean on a Felicity inverter?
It depends on the model — 11 devices use code 08. On the IVCM1012 PRO it means: Fan 1 locked. The card for each model on this page gives its exact meaning and fix.
Is error 08 a fault or a warning?
It depends on the model: on some models 08 is a fault (output cut, red LED solid), on others a warning (red LED flashing, unit keeps running). Check the card for your model on this page.
How do I clear or fix error 08?
Check if the Fans wiring connected well. Replace the fan. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.