29Fault

Felicity inverter error 29 (F29)

Inverter current sensor faulty

Also displayed as F29 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

IVCM1012 PRO

InverterFault

Also applies to:IVCM2024 PROIVCM3024 PRO

What it means

Inverter current sensor faultyThe inverter current sensor is faulty.

Cause: The inverter-stage current sensor is faulty and its readings can no longer be trusted. This is an internal component failure.

How to fix it

Contact the repair center.

Source: ICM.pdf, p.14

T-REX-3KLP1G01

InverterFault

Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01T-REX-10KHP3G01T-REX-10KLP3G01

What it means

Inverter current sensor failed

Cause: The inverter-stage current sensor returned an out-of-range or implausible reading, so the control board can no longer trust its inverter current measurement.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.38 · T-REX-10KHP3G01-Inverter-User-Guide.pdf, p.28 · T-REX-10KLP3G01-Inverter-User-Guide.pdf, p.28

IVEM 6048

InverterFault

Also applies to:IVEM6048

What it means

DC/DC soft start fail

Cause: Internal failure during DC/DC soft start.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.38

IVEM8048-II

InverterFault

Also applies to:IVEM12048-IIIVEM 8K-12K Series II

What it means

DC/DC soft start fail

Cause: DC/DC converter soft start failure.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: IVEM8K-12K-II_compressed.pdf, p.44

IVEM8048-LV

InverterFault

Also applies to:IVEM8048

What it means

DC/DC soft start fail

Cause: The DC/DC converter failed to ramp up to its working voltage during soft start, which indicates an internal component fault rather than a wiring problem.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.39

T-REX-50KHP3G01

InverterFault

What it means

Battery 2 relay short circuit faultBattery 2 relay not properly disconnected causing short circuit, shutdown and restart.

Cause: A safety relay inside the inverter has failed self-test or is stuck. The inverter is designed to refuse grid connection in this state, so this is not an issue you can clear with restart cycles.

How to fix it

  1. This requires service — the relay assembly is not user-replaceable.
  2. Record the exact fault code and contact your installer or the manufacturer's service line.
  3. Do not bypass any safety interlock.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.46

Apollo-5KLP1G01-MX

Energy storage systemCritical

Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2

What it means

Inverter current sensor failed

Cause: Inverter current sensor failed.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.43

Frequently asked questions

What does error 29 mean on a Felicity inverter?
It depends on the model — 9 devices use code 29. On the IVCM1012 PRO it means: Inverter current sensor faulty. The card for each model on this page gives its exact meaning and fix.
Is error 29 a fault or a warning?
29 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 29?
Contact the repair center. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.