What it means
INV NTC is disconnected — The inverter temperature sensor (NTC) is disconnected.
Cause: The inverter temperature sensor wiring is disconnected or the sensor failed.
How to fix it
Contact the repair center.
Source: IVPS-IVPM User Guide.pdf, p.18 · IVPS3524P1G1-LV IVPS5048P1G1-LV IVPS7548P2G1 IVPS10048P2G1 User Guide - EN.pdf, p.27
Also applies to:IVCM2024 PROIVCM3024 PRO
What it means
Battery voltage too high — Battery voltage is too high.
Cause: The measured battery voltage is above the allowed maximum for the configured system voltage: either an external source is overcharging the battery, or an internal measurement or charging component has failed.
How to fix it
- 1Internal components failed.
- 2Restart the unit, if the error persists, contact the repair center.
Source: ICM.pdf, p.13
Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01
What it means
Battery voltage is too high — The battery voltage is too low, it should be charging.
Cause: When shown as a fault, the battery voltage at the terminals is above the inverter's permitted range — usually a battery bank whose specification or series count does not match the unit. The same number appears in the warning list for low battery voltage, meaning the pack needs charging.
How to fix it
Check if spec and quantity of batteries are meet requirements.
Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.37
Also applies to:IVEM6048IVEM8048-LVIVEM8048
What it means
Output voltage is too low
Cause: Connected load is too high or internal failure.
How to fix it
- 1Reduce the connected load.
- 2Restart the unit, if the error persists, contact the repair center.
Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.37 · FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.38
Also applies to:IVEM12048-IIIVEM 8K-12K Series II
What it means
Output voltage is too low
Cause: Output voltage below acceptable range, possibly due to overload.
How to fix it
- 1Reduce the connected load.
- 2Restart the unit, if the error persists, contact the repair center.
Source: IVEM8K-12K-II_compressed.pdf, p.43
Also applies to:T-REX-10KLP3G01
What it means
Battery voltage is too high
Cause: Battery specification or quantity does not meet requirements.
How to fix it
Check if spec and quantity of batteries are meet requirements.
Source: T-REX-10KHP3G01-Inverter-User-Guide.pdf, p.28 · T-REX-10KLP3G01-Inverter-User-Guide.pdf, p.27
What it means
PV3 overcurrent fault — The current of the PV3 is too large, check the string current.
Cause: Current from the PV3 string exceeded the input stage's protection limit — more current than that MPPT channel is rated to carry.
How to fix it
- 1Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
- 2If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.
Source: T-REX-50KHP3G01-user-manual-.pdf, p.45
Energy storage systemFault Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2
What it means
Battery voltage is too high — Battery voltage exceeds the maximum allowed value.
Cause: Battery voltage is too high.
How to fix it
Check if spec and quantity of batteries are meet requirements.
Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.42
Also applies to:LUX-X-96050HMG01LUX-X-96050HCG01
What it means
High BMS Temperature — BMS internal temperature has exceeded safe operating limit.
Cause: BMS overheating due to high ambient temperature, poor ventilation, or high current operation.
How to fix it
Stop charging and discharging, wait for the temperature to drop.
Source: LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf, p.21
Also applies to:LUX-Y-48100HCG01LUX-Y-48100HMG01LUX-Y-48100HR13G01LUX-Y-48100HR9G01
What it means
High BMS Temperature — BMS temperature is too high.
Cause: BMS overheating due to high ambient temperature, poor ventilation, or high-current operation.
How to fix it
Stop charging and discharging, wait for the temperature to drop.
Source: LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf, p.20
What it means
High BMS Temperature
Cause: BMS overheating due to high ambient temperature, poor ventilation, or high-current operation.
How to fix it
- 1Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
- 2If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.
Source: LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf, p.27
Charge controllerCritical Also applies to:SCCM4524-IIISCCM4548-IIISCCM6048-IIISCCM8048-IIISCCM10048-IIISCCM12048-III
What it means
Battery temperature is too high — Detected battery temperature exceeds the safe charging range.
Cause: Battery ambient temperature is too high, or remote temperature sensor (RTS) is faulty, disconnected, or reporting incorrect values.
How to fix it
- 1Check your remote temperature sensor and your battery ambient temperature
- 2If the problem remains, please contact your installer.
Source: felicitysolar SCCM-III MPPT Solar Charge Controller User Guide.pdf, p.18
What it means
Heat sink temperature is too high — Fault event: heat sink temperature exceeded its high threshold.
Cause: The heat-sink temperature exceeded its upper protection limit — high ambient temperature, blocked ventilation, or sustained high-power operation.
How to fix it
- 1Restart the unit.
- 2If the error persists, contact the repair center.
Source: LUX-S-1600LG01.pdf, p.22