Also applies to:IVPS2512IVPS2524IVPS3524IVPS5024IVPS5048IVPS7548IVPS-7548IVPS10048+9
What it means
Battery low — The battery voltage is too low.
Cause: The battery is discharged below the low-voltage warning level.
How to fix it
The voltage of the battery is too low; the battery should be charged.
Source: IVPS-IVPM User Guide.pdf, p.18 · IVPS3524P1G1-LV IVPS5048P1G1-LV IVPS7548P2G1 IVPS10048P2G1 User Guide - EN.pdf, p.27
Also applies to:IVCM2024 PROIVCM3024 PRO
What it means
PV temperature is too high
Cause: The PV charger stage has overheated above its protection limit, typically because the unit's airflow is blocked or the ambient temperature is too high.
How to fix it
Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.
Source: ICM.pdf, p.13
Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01
What it means
Short circuit happen at PV port
Cause: A short circuit was detected at the PV input — the array wiring presents a near-zero-resistance path, so the input stage shut down.
How to fix it
Check if wiring is connect well.
Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.37
Also applies to:IVEM6048IVEM8048-IIIVEM12048-IIIVEM 8K-12K Series IIIVEM8048-LVIVEM8048
What it means
Inverter soft start fail
Cause: Internal components failed.
How to fix it
Restart the unit, if the error persists, contact the repair center.
Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.36 · IVEM8K-12K-II_compressed.pdf, p.43 · FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.37
What it means
Short circuit happen at PV port — Short circuit at the PV port.
Cause: A short circuit was detected at the PV input — the array wiring presents a near-zero-resistance path, so the input stage shut down.
How to fix it
Check if wiring is connected well.
Source: T-REX-10KHP3G01-Inverter-User-Guide.pdf, p.28
What it means
Short circuit happen at PV port
Cause: A short circuit was detected at the PV input — the array wiring presents a near-zero-resistance path, so the input stage shut down.
How to fix it
Check if wiring is connect well.
Source: T-REX-10KLP3G01-Inverter-User-Guide.pdf, p.27
What it means
PV4 overvoltage fault — The voltage of the PV4 is too high, check the voltage of the string.
Cause: The open-circuit voltage of the PV4 string is above the inverter's permitted DC input range — typically a string configured with too many modules in series.
How to fix it
- 1Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
- 2If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.
Source: T-REX-50KHP3G01-user-manual-.pdf, p.45
Energy storage systemCritical Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2
What it means
Short circuit happen at PV port
Cause: Short circuit happen at PV port.
How to fix it
Check if wiring is connect well.
Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.42
Also applies to:LUX-X-96050HMG01LUX-X-96050HCG01
What it means
Low Cell Voltage — Individual cell voltage below minimum allowed value.
Cause: Cell-level undervoltage (imbalance or deep discharge of a single cell).
How to fix it
- 1Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
- 2If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.
Source: LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf, p.21
Also applies to:LUX-Y-48100HCG01LUX-Y-48100HMG01LUX-Y-48100HR13G01LUX-Y-48100HR9G01
What it means
Low Cell Voltage — Individual cell voltage fell below the lower threshold.
Cause: Cell-level undervoltage — imbalance or deep discharge of a single cell.
How to fix it
- 1Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
- 2If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.
Source: LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf, p.20
What it means
Low Cell Voltage
Cause: Cell-level undervoltage — imbalance or deep discharge of a single cell.
How to fix it
- 1Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
- 2If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.
Source: LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf, p.27
Charge controllerCritical Also applies to:SCCM4524-IIISCCM4548-IIISCCM6048-IIISCCM8048-IIISCCM10048-IIISCCM12048-III
What it means
Battery voltage is high — Battery voltage has exceeded the controller's high-voltage disconnect threshold.
Cause: Battery overvoltage condition, possibly due to incorrect battery system voltage setting or external charging source raising battery voltage above safe limits.
How to fix it
- 1Reconnect the battery to the charger
- 2If the problem remains, please contact your installer.
Source: felicitysolar SCCM-III MPPT Solar Charge Controller User Guide.pdf, p.18
What it means
Cell voltage is too low — Fault event: an individual battery cell voltage fell below its low threshold. Inverter cuts off output and fault LED solid on.
Cause: An individual cell voltage fell below its lower threshold — imbalance or deep discharge of a single cell.
How to fix it
- 1Restart the unit.
- 2If the error persists, contact the repair center.
Source: LUX-S-1600LG01.pdf, p.22