21Fault

Felicity inverter error 21 (F21)

Over current happen in charging mode

Also displayed as F21 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

IVPS/IVPM Series

InverterFault

Also applies to:IVPS2512IVPS2524IVPS3524IVPS5024IVPS5048IVPS7548IVPS-7548IVPS10048+9

What it means

Over current happen in charging modeOver current is detected while charging the battery.

Cause: While charging the battery, current through the charger stage exceeded its protection limit. The trip is raised by the internal charging circuit, so persistent recurrence indicates a charger-stage fault rather than a battery wiring problem.

How to fix it

Contact the repair center.

Source: IVPS-IVPM User Guide.pdf, p.17 · IVPS3524P1G1-LV IVPS5048P1G1-LV IVPS7548P2G1 IVPS10048P2G1 User Guide - EN.pdf, p.24

IVCM1012 PRO

InverterFault

Also applies to:IVCM2024 PROIVCM3024 PRO

What it means

OP current sensor failedOP (output) current sensor failed.

Cause: The output current sensor has failed, so the inverter can no longer measure its output current reliably. This is an internal component fault.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: ICM.pdf, p.13

IVGM5KL-P1G1

InverterFault

Also applies to:IVGM6KL-P1G1IVGM7K6L-P1G1IVGM8KL-P1G1

What it means

BMS communication AlarmAbnormal communication between battery and inverter in non-SOC mode, check battery and inverter wiring.

Cause: Communication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.

How to fix it

Check battery and inverter wiring.

Source: Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf, p.51

T-REX-3KLP1G01

InverterFault

Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01T-REX-10KHP3G01

What it means

OP current sensor failedOutput current sensor failed.

Cause: The output current sensor returned an out-of-range or implausible reading, so the control board can no longer trust its output-current measurement.

How to fix it

Output current sensor failed.

Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.38 · T-REX-10KHP3G01-Inverter-User-Guide.pdf, p.28

IVEM 6048

InverterFault

Also applies to:IVEM6048IVEM8048-IIIVEM12048-IIIVEM 8K-12K Series IIIVEM8048-LVIVEM8048

What it means

The inner temperature over

Cause: The inner temperature is over the limitation.

How to fix it

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.37 · IVEM8K-12K-II_compressed.pdf, p.44 · FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.38

T-REX-10KLP3G01

InverterFault

What it means

OP current sensor failedOutput current sensor failed.

Cause: Output current sensor failed.

How to fix it

Output current sensor failed.

Source: T-REX-10KLP3G01-Inverter-User-Guide.pdf, p.28

T-REX-50KHP3G01

InverterFault

What it means

Battery 2 software overcurrent faultBattery 2 current is too large, check the battery charge and discharge power.

Cause: The control firmware measured battery 2 current above the protection limit — charge or discharge power beyond what that battery channel is rated for.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.46

Apollo-5KLP1G01-MX

Energy storage systemCritical

Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2

What it means

OP current sensor failedOutput current sensor failed.

Cause: Output current sensor failed.

How to fix it

Output current sensor failed.

Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.43

LUX-S-1600LG01

BatteryFault

What it means

PV Mos ShortFault event: PV input MOSFET short-circuit fault detected.

Cause: A fault has been detected in the PV input stage — usually a short, ground fault, or isolation failure between the PV array and the inverter chassis. Wet connectors, damaged cable insulation, or moisture in a junction box are common causes.

How to fix it

  1. Restart the unit.
  2. If the error persists, contact the repair center.

Source: LUX-S-1600LG01.pdf, p.22

Frequently asked questions

What does error 21 mean on a Felicity inverter?
It depends on the model — 13 devices use code 21. On the IVPS/IVPM Series it means: Over current happen in charging mode. The card for each model on this page gives its exact meaning and fix.
Is error 21 a fault or a warning?
21 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 21?
Contact the repair center. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.