E-CHO-SI3KS2
Inverter32 codesE0Grid Volt Low.Fault
Grid voltage below acceptable range.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E1Grid Volt High.Fault
Grid voltage above acceptable range.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E2Grid Freq Low.Fault
Grid frequency below acceptable range.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E3Grid Freq High.Fault
Grid frequency above acceptable range.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E4Bus Volt Low.Fault
DC bus voltage low.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E5Bus Volt High.Fault
DC bus voltage high.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E6Reserved.Fault
Reserved code.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E7Isolation Fault.Fault
PV array insulation/isolation impedance to ground is too low.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E8Input Curr Over.Fault
PV input current over the allowed range.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E9Hard Curr Over.Fault
Hardware current over-protection triggered.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E10Inv Curr Over.Fault
Inverter output current over-protection triggered.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E11Inv DCI Over.Fault
Inverter DC injection current over the allowed limit.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E12Amb Temp Over.Fault
Ambient temperature over the allowed limit.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17E13Sink Temp Over.Fault
Heat sink temperature over the allowed limit.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17E14AC Relay Fault.Fault
AC relay fault detected.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17E15Reserved.Fault
Reserved code.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17E16Remote Off.Fault
Inverter shut down by remote/background instruction.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E17Reserved.Fault
Reserved code.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E18SPI Comm Fault.Fault
SPI internal communication fault.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E19Reserved.Fault
Reserved code.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E20GFCI over Fault.Fault
Ground Fault Circuit Interrupter (leakage current) over-protection.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E21GFCI Dev. Fault.Fault
GFCI device self-test/detection fault.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E22Volt Cons Fault.Fault
Voltage consistency fault between master and slave samples.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E23Curr inconsiste.Fault
Current sampling inconsistency between master and slave.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E24Freq inconsiste.Fault
Frequency sampling inconsistency between master and slave.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E25GFCI inconsiste.Fault
GFCI sampling inconsistency between master and slave.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E26Soft start fail.Fault
Soft start failure during inverter startup.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E27Reserved.Fault
Reserved code.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16E32DSP Comm Fault.Fault
DSP communication fault.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17E33Login Fault.Fault
Login fault.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17W03Power is zero.Fault
Output power is zero.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17W16Clock Warn.Fault
Internal clock/RTC warning, button battery low.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17Compiled from official FelicityESS user manuals. Always consult your device manual and a qualified technician before performing repairs.