E-CHO-SI3KS2

Inverter32 codes
32 Fault

About the Felicity E-CHO-SI3KS2

The Felicity E-CHO-SI3KS2 is a Inverter unit. The 32 error codes listed below are the complete fault catalog for this device, compiled from the official Felicity user manual.

How to use this page

Each row below shows an error code, its severity, and a brief description. Click any row to expand the full cause and the recommended fix. The severity dot tells you whether the unit will keep operating (warning), derate (fault), or trip offline (critical). For codes that require an authorized service partner, the recommended-fix block says so explicitly.

E0Grid Volt Low.Fault
Description

Grid voltage below acceptable range.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E1Grid Volt High.Fault
Description

Grid voltage above acceptable range.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E2Grid Freq Low.Fault
Description

Grid frequency below acceptable range.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E3Grid Freq High.Fault
Description

Grid frequency above acceptable range.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E4Bus Volt Low.Fault
Description

DC bus voltage low.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E5Bus Volt High.Fault
Description

DC bus voltage high.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E6Reserved.Fault
Description

Reserved code.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E7Isolation Fault.Fault
Description

PV array insulation/isolation impedance to ground is too low.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E8Input Curr Over.Fault
Description

PV input current over the allowed range.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E9Hard Curr Over.Fault
Description

Hardware current over-protection triggered.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E10Inv Curr Over.Fault
Description

Inverter output current over-protection triggered.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E11Inv DCI Over.Fault
Description

Inverter DC injection current over the allowed limit.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E12Amb Temp Over.Fault
Description

Ambient temperature over the allowed limit.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 17
E13Sink Temp Over.Fault
Description

Heat sink temperature over the allowed limit.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 17
E14AC Relay Fault.Fault
Description

AC relay fault detected.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 17
E15Reserved.Fault
Description

Reserved code.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 17
E16Remote Off.Fault
Description

Inverter shut down by remote/background instruction.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E17Reserved.Fault
Description

Reserved code.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E18SPI Comm Fault.Fault
Description

SPI internal communication fault.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E19Reserved.Fault
Description

Reserved code.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E20GFCI over Fault.Fault
Description

Ground Fault Circuit Interrupter (leakage current) over-protection.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E21GFCI Dev. Fault.Fault
Description

GFCI device self-test/detection fault.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E22Volt Cons Fault.Fault
Description

Voltage consistency fault between master and slave samples.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E23Curr inconsiste.Fault
Description

Current sampling inconsistency between master and slave.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E24Freq inconsiste.Fault
Description

Frequency sampling inconsistency between master and slave.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E25GFCI inconsiste.Fault
Description

GFCI sampling inconsistency between master and slave.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E26Soft start fail.Fault
Description

Soft start failure during inverter startup.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E27Reserved.Fault
Description

Reserved code.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 16
E32DSP Comm Fault.Fault
Description

DSP communication fault.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 17
E33Login Fault.Fault
Description

Login fault.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 17
W03Power is zero.Fault
Description

Output power is zero.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 17
W16Clock Warn.Fault
Description

Internal clock/RTC warning, button battery low.

Source:E-CHO-SI3KS2-Operation-Manual.pdf · page 17

Step-by-step troubleshooting checklist

  1. 1.Note the exact code and timing

    Write down the exact code shown on the display, what the unit was doing when it appeared (charging, discharging, idle, grid-tied), and any LEDs or audible alarms. The same code can have different fixes depending on context.

  2. 2.Check the recommended fix on this page

    Find the code in the list below and read the cause + recommended fix. Most warning-level codes can be cleared by following the listed action — usually reducing load, checking wiring, or restarting the unit.

  3. 3.Verify the source manual page

    Each code shows the source manual filename and page number. Open that exact page in the official manual to verify model-specific notes (firmware version, parallel-config notes, regional variants) before acting.

  4. 4.Disconnect AC, DC, and battery before opening

    If a fix requires opening the enclosure or accessing terminals, disconnect AC input, DC PV, and battery in that order. Wait at least 60 seconds for capacitors to discharge before touching any conductors.

  5. 5.Escalate critical codes to authorized service

    Critical codes (short-circuit, IGBT failure, BMS hardware error) should not be cleared by end users. Note the code, model number, and source manual page, then contact an authorized service partner.

Common questions about E-CHO-SI3KS2 error codes

Where can I find the official Felicity E-CHO-SI3KS2 error code manual?
Each code on this page lists the official source manual filename and page number at the bottom. The manuals are published by Felicity on their website; we compile the codes here so you can search across all of them at once instead of opening each PDF.
Is the E-CHO-SI3KS2 the same as other Felicity models?
Some Felicity units share firmware across a family of variants — the same fault codes apply to multiple model numbers. Look at the "also covers" chips below the title to see which other model numbers this page applies to.
What's the most critical code on a Felicity E-CHO-SI3KS2?
Critical-severity codes (red dot) are the ones that trip the unit offline immediately — typically short-circuit, IGBT, or BMS hardware failures. These are listed first when you filter by severity. Do not bypass them; they indicate a hardware or safety condition that requires service.

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.