About the Felicity E-CHO-SI3KS2
The Felicity E-CHO-SI3KS2 is a Inverter unit. The 32 error codes listed below are the complete fault catalog for this device, compiled from the official Felicity user manual.
The Felicity E-CHO-SI3KS2 is a Inverter unit. The 32 error codes listed below are the complete fault catalog for this device, compiled from the official Felicity user manual.
Each row below shows an error code, its severity, and a brief description. Click any row to expand the full cause and the recommended fix. The severity dot tells you whether the unit will keep operating (warning), derate (fault), or trip offline (critical). For codes that require an authorized service partner, the recommended-fix block says so explicitly.
Grid voltage below acceptable range.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Grid voltage above acceptable range.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Grid frequency below acceptable range.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Grid frequency above acceptable range.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16DC bus voltage low.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16DC bus voltage high.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Reserved code.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16PV array insulation/isolation impedance to ground is too low.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16PV input current over the allowed range.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Hardware current over-protection triggered.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Inverter output current over-protection triggered.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Inverter DC injection current over the allowed limit.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Ambient temperature over the allowed limit.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17Heat sink temperature over the allowed limit.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17AC relay fault detected.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17Reserved code.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17Inverter shut down by remote/background instruction.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Reserved code.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16SPI internal communication fault.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Reserved code.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Ground Fault Circuit Interrupter (leakage current) over-protection.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16GFCI device self-test/detection fault.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Voltage consistency fault between master and slave samples.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Current sampling inconsistency between master and slave.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Frequency sampling inconsistency between master and slave.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16GFCI sampling inconsistency between master and slave.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Soft start failure during inverter startup.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16Reserved code.
E-CHO-SI3KS2-Operation-Manual.pdf · page 16DSP communication fault.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17Login fault.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17Output power is zero.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17Internal clock/RTC warning, button battery low.
E-CHO-SI3KS2-Operation-Manual.pdf · page 17Write down the exact code shown on the display, what the unit was doing when it appeared (charging, discharging, idle, grid-tied), and any LEDs or audible alarms. The same code can have different fixes depending on context.
Find the code in the list below and read the cause + recommended fix. Most warning-level codes can be cleared by following the listed action — usually reducing load, checking wiring, or restarting the unit.
Each code shows the source manual filename and page number. Open that exact page in the official manual to verify model-specific notes (firmware version, parallel-config notes, regional variants) before acting.
If a fix requires opening the enclosure or accessing terminals, disconnect AC input, DC PV, and battery in that order. Wait at least 60 seconds for capacitors to discharge before touching any conductors.
Critical codes (short-circuit, IGBT failure, BMS hardware error) should not be cleared by end users. Note the code, model number, and source manual page, then contact an authorized service partner.
Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.