03Fault

Felicity inverter error 03 (F03)

PV charging overcurrent

Also displayed as F03 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

Severity differs by model — check your model below.

The exact meaning depends on your model:

IVCM1012 PRO

InverterFault

Also applies to:IVCM2024 PROIVCM3024 PRO

What it means

PV charging overcurrent

Cause: The charging current from the PV input exceeded the charger stage's protection limit: the array is delivering more current than the charging circuit is rated to handle.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: ICM.pdf, p.13

IVEM 6048

InverterFault

Also applies to:IVEM6048IVEM8048-IIIVEM12048-IIIVEM 8K-12K Series IIIVEM8048-LVIVEM8048

What it means

Bus soft start fail

Cause: Internal components failed.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.36 · IVEM8K-12K-II_compressed.pdf, p.43 · FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.37

T-REX-50KHP3G01

InverterFault

What it means

PV3 overvoltage faultThe voltage of the PV3 is too high, check the voltage of the string.

Cause: The open-circuit voltage of the PV3 string is above the inverter's permitted DC input range — typically a string configured with too many modules in series.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.45

LUX-X-96050HG01

BatteryWarning

Also applies to:LUX-X-96050HMG01LUX-X-96050HCG01

What it means

High Cell VoltageIndividual cell voltage exceeds maximum allowed value.

Cause: Cell-level overvoltage (imbalance or overcharge of a single cell).

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf, p.21

LUX-Y-48100HG01

BatteryWarning

Also applies to:LUX-Y-48100HCG01LUX-Y-48100HMG01LUX-Y-48100HR13G01LUX-Y-48100HR9G01

What it means

High Cell VoltageIndividual cell voltage exceeded the upper threshold.

Cause: Cell-level overvoltage — imbalance or overcharge of a single cell.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf, p.20

LUX-Y-48100HG01MN

BatteryFault

What it means

High Cell Voltage

Cause: Cell-level overvoltage — imbalance or overcharge of a single cell.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf, p.27

SCCM3024-III

Charge controllerCritical

Also applies to:SCCM4524-IIISCCM4548-IIISCCM6048-IIISCCM8048-IIISCCM10048-IIISCCM12048-III

What it means

Battery voltage is too lowThe connected battery voltage has dropped below the acceptable minimum threshold.

Cause: Loose, broken, or improperly connected battery wiring, or a deeply discharged/damaged battery.

How to fix it

  1. Check the battery wire connection
  2. If the wire connection is ok, please contact your installer.

Source: felicitysolar SCCM-III MPPT Solar Charge Controller User Guide.pdf, p.18

LUX-S-1600LG01

BatteryFault

What it means

Cell voltage is too highFault event: an individual battery cell voltage exceeded its high threshold. Inverter cuts off output and fault LED solid on.

Cause: An individual cell voltage exceeded its upper threshold — imbalance or overcharge of a single cell.

How to fix it

  1. Restart the unit.
  2. If the error persists, contact the repair center.

Source: LUX-S-1600LG01.pdf, p.22

Frequently asked questions

What does error 03 mean on a Felicity inverter?
It depends on the model — 10 devices use code 03. On the IVCM1012 PRO it means: PV charging overcurrent. The card for each model on this page gives its exact meaning and fix.
Is error 03 a fault or a warning?
It depends on the model: on some models 03 is a fault (output cut, red LED solid), on others a warning (red LED flashing, unit keeps running). Check the card for your model on this page.
How do I clear or fix error 03?
Restart the unit, if the error persists, contact the repair center. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.