09Fault

Felicity inverter error 09 (F09)

Fan 2 locked

Also displayed as F09 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

Severity differs by model — check your model below.

The exact meaning depends on your model:

IVCM1012 PRO

InverterFault

Also applies to:IVCM2024 PROIVCM3024 PRO

What it means

Fan 2 lockedFan 2 is locked.

Cause: Internal cooling fan failure detected. Often caused by dust buildup, bearing wear, or debris fouling the fan blades.

How to fix it

  1. Check if the Fans wiring connected well.
  2. Replace the fan.

Source: ICM.pdf, p.13

T-REX-3KLP1G01

InverterFault

Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01

What it means

Overload

Cause: The connected load exceeds the inverter's continuous output rating; the buzzer beeps twice every second and protection will cut the output if the load is not reduced.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.37

IVEM 6048

InverterFault

Also applies to:IVEM6048

What it means

Output short circuited

Cause: Wiring issue or abnormal load causing a short circuit.

How to fix it

Check if wiring is connected well and remove abnormal load.

Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.37

IVEM8048-II

InverterFault

Also applies to:IVEM12048-IIIVEM 8K-12K Series II

What it means

Output short circuited

Cause: Short circuit on AC output wiring or connected load.

How to fix it

Check if wiring is connected well and remove abnormal load.

Source: IVEM8K-12K-II_compressed.pdf, p.43

IVEM8048-LV

InverterFault

Also applies to:IVEM8048

What it means

Output short circuited

Cause: Wiring not connected well or abnormal load.

How to fix it

Check if wiring is connected well and remove abnormal load.

Source: FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.38

T-REX-50KHP3G01

InverterFault

What it means

PV1 reverse connection faultPv1 string positive and negative connection, check the string wiring.

Cause: The PV1 string is connected with positive and negative reversed, so the input stage blocks it until the string wiring is corrected.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.45

LUX-X-96050HG01

BatteryWarning

Also applies to:LUX-X-96050HMG01LUX-X-96050HCG01

What it means

High Cell TemperatureBattery cell temperature has exceeded safe operating limit.

Cause: Cell overheating due to high ambient temperature or high current operation.

How to fix it

Stop charging and discharging, wait for the temperature to drop.

Source: LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf, p.21

LUX-Y-48100HG01

BatteryWarning

Also applies to:LUX-Y-48100HCG01LUX-Y-48100HMG01LUX-Y-48100HR13G01LUX-Y-48100HR9G01

What it means

High Cell TemperatureCell temperature is too high.

Cause: Cell overheating due to high ambient temperature or high-current operation.

How to fix it

Stop charging and discharging, wait for the temperature to drop.

Source: LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf, p.20

LUX-Y-48100HG01MN

BatteryFault

What it means

High Cell Temperature

Cause: Cell overheating due to high ambient temperature or high-current operation.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf, p.27

LUX-S-1600LG01

BatteryFault

What it means

Cell temperature is too highFault event: battery cell temperature exceeded its high threshold (operating ranges: charging 0 to 55 deg C, discharging -20 to 55 deg C).

Cause: A battery cell temperature exceeded the upper protection limit — possibly excessive ambient temperature, high current, or impaired ventilation.

How to fix it

  1. Restart the unit.
  2. If the error persists, contact the repair center.

Source: LUX-S-1600LG01.pdf, p.22

Frequently asked questions

What does error 09 mean on a Felicity inverter?
It depends on the model — 10 devices use code 09. On the IVCM1012 PRO it means: Fan 2 locked. The card for each model on this page gives its exact meaning and fix.
Is error 09 a fault or a warning?
It depends on the model: on some models 09 is a fault (output cut, red LED solid), on others a warning (red LED flashing, unit keeps running). Check the card for your model on this page.
How do I clear or fix error 09?
Check if the Fans wiring connected well. Replace the fan. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.