IVEM8048-LV

Onduleur47 codes
also coversIVEM8048
39 Défaut 8 Avertissement
F01Bus voltage is too high.Défaut
Description

Bus voltage is too high.

Cause

AC Surge or internal components failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
F02Bus voltage is too low.Défaut
Description

Bus voltage is too low.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
F03Bus soft start fail.Défaut
Description

Bus soft start fail.

Cause

Internal components failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
F04Inverter soft start fail.Défaut
Description

Inverter soft start fail.

Cause

Internal components failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
F05Over current or surge detected by Software.Défaut
Description

Over current or surge detected by Software.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
F06Over current or surge detected by hardware.Défaut
Description

Over current or surge detected by hardware.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
F07Output voltage is too low.Défaut
Description

Output voltage is too low.

Correction recommandée

Reduce the connected load. Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F08Output voltage is too high.Défaut
Description

Output voltage is too high.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F09Output short circuited.Défaut
Description

Output short circuited.

Cause

Wiring not connected well or abnormal load.

Correction recommandée

Check if wiring is connected well and remove abnormal load.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F10Overload time out.Défaut
Description

Overload time out.

Cause

Connected load exceeds inverter capacity for an extended time.

Correction recommandée

Reduce the connected load by switching off some equipment.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F11Battery voltage is too high.Défaut
Description

Battery voltage is too high.

Cause

Battery spec or quantity does not meet requirements.

Correction recommandée

Check if spec and quantity of batteries are meet requirements.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F12Over current happen at DC/DC circuit.Défaut
Description

Over current happen at DC/DC circuit.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F13PV voltage is too high.Défaut
Description

PV voltage is too high.

Cause

Too many PV modules in series.

Correction recommandée

Reduce the number of PV modules in series.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F14Short circuited happen at PV port.Défaut
Description

Short circuited happen at PV port.

Cause

Wiring not connected well.

Correction recommandée

Check if wiring is connected well.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F15PV power is abnormal.Défaut
Description

PV power is abnormal.

Cause

Excessive PV power input.

Correction recommandée

Reduce the number of PV modules.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F16Over current happen at PV port.Défaut
Description

Over current happen at PV port.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F17Fan is locked.Défaut
Description

Fan is locked.

Cause

Fan wiring problem or fan failure.

Correction recommandée

Check if wiring is connected well. Replace the fan.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F18Over temperature happen at PV circuit.Défaut
Description

Over temperature happen at PV circuit.

Cause

The temperature of internal PV component is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F19Over temperature happen at Convert L circuit.Défaut
Description

Over temperature happen at Convert L circuit.

Cause

The temperature of Convert L battery converter component is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F20Over temperature happen at INV circuit.Défaut
Description

Over temperature happen at INV circuit.

Cause

The temperature of internal INV component is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F21The inner temperature over.Défaut
Description

The inner temperature over.

Cause

The inner temperature is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F22DCDC current sensor failed.Défaut
Description

DCDC current sensor failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F23No.2 DCDC current sensor failed.Défaut
Description

No.2 DCDC current sensor failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F24Inverter current sensor failed.Défaut
Description

Inverter current sensor failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F25OP current sensor failed.Défaut
Description

OP current sensor failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F26Sharing current sensor failed.Défaut
Description

Sharing current sensor failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F27The AC input and output wires are inversely connected.Défaut
Description

The AC input and output wires are inversely connected.

Cause

AC input and output wiring reversed, possibly during parallel installation.

Correction recommandée

1. Please check AC input and output wires are connected correctly. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please funish parallel installation first, and then restart inverters. 3. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F28Single unit is installed to parallel system.Défaut
Description

Single unit is installed to parallel system.

Cause

Single unit configured into a parallel system, or wiring problem during parallel installation.

Correction recommandée

1. Please check if single unit is installed to parallel system. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please funish parallel installation first, and then restart inverters. 3. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F29DC/DC soft start fail.Défaut
Description

DC/DC soft start fail.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F31Over temperature happen at convert H circuit.Défaut
Description

Over temperature happen at convert H circuit.

Cause

The temperature of internal convert H component is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F32Over temperature happen at LLC TX.Défaut
Description

Over temperature happen at LLC TX.

Cause

The temperature of internal DC/DC TX is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F33Over current happen at LLC circuit.Défaut
Description

Over current happen at LLC circuit.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F40CAN data loss.Défaut
Description

CAN data loss.

Cause

Communication failure between paralleled inverters.

Correction recommandée

1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F41Host data loss.Défaut
Description

Host data loss.

Cause

Communication failure between paralleled inverters.

Correction recommandée

1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F42Synchronization data loss.Défaut
Description

Synchronization data loss.

Cause

Communication failure between paralleled inverters.

Correction recommandée

1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F43Current feedback into the inverter is detected.Défaut
Description

Current feedback into the inverter is detected.

Cause

Reverse-connected L/N cables, or sharing cables not connected/connected across phases in three-phase setup.

Correction recommandée

1. Restart the inverter. 2. Check if L/N cables are not connected reversely in all inverters. 3. For parallel system in single phase, make sure the sharing cables are connected in all inverters. For supporting three-phase system, make sure the sharing cables are connected in the inverters in the same phase, and disconnected in the inverters in different phases. 4. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F44The firmware version of each inverter is not the same.Défaut
Description

The firmware version of each inverter is not the same.

Cause

Mismatched firmware versions across paralleled inverters.

Correction recommandée

1. Update all inverter firmware to the same version. 2. Check the version of each inverter via LCD setting and make sure the CPU versions are same. if not, please contact your installer to provide the firmware to update. 3. After updating, if the problem still remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F45The output current of each inverter is different.Défaut
Description

The output current of each inverter is different.

Cause

Sharing cable connection issue between paralleled inverters.

Correction recommandée

1. Check if sharing cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F46AC output mode setting is different.Défaut
Description

AC output mode setting is different.

Cause

Inconsistent AC output mode (program 28) settings across inverters.

Correction recommandée

1. Switch off the inverter and check LCD setting program 28. 2. For parallel system in single phase, make sure no 3P1, 3P2 or 3P3 is set on program 28. For supporting three-phase system, make sure no "PAL" is set on program 28. 3. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
W01Fan is locked.Avertissement
Description

Warning: Fan is locked. Beep three times every second.

Cause

Fan wiring not connected well or fan failure.

Correction recommandée

Check if the Fan's wiring connected well. Replace the fan.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
W02Overload.Avertissement
Description

Warning: Overload. Beep twice every second.

Cause

Connected load exceeds the inverter capacity.

Correction recommandée

Reduce the loads.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
W03Low battery.Avertissement
Description

Warning: Low battery. Beep once every second.

Cause

The battery voltage is too low.

Correction recommandée

It should be charging.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
W50BMS firmware version is not matched.Avertissement
Description

BMS firmware version is not matched.

Cause

BMS firmware version mismatch.

Correction recommandée

Upgrade the firmware of BMS.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
W51BMS doesn't allow inverter to charge battery.Avertissement
Description

BMS doesn't allow inverter to charge battery.

Cause

BMS has blocked charging.

Correction recommandée

Inverter will stop charging battery automatically.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
W52BMS doesn't allow inverter to discharge battery.Avertissement
Description

BMS doesn't allow inverter to discharge battery.

Cause

BMS has blocked discharging.

Correction recommandée

Inverter will stop discharging battery automatically.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
W53BMS require inverter to charge battery.Avertissement
Description

BMS require inverter to charge battery.

Cause

BMS has requested charging.

Correction recommandée

Inverter will charge battery automatically.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37
W54~65BMS detect something wrongs happened.Avertissement
Description

BMS detect something wrongs happened (range of codes 54 through 65).

Cause

BMS has detected an internal fault.

Correction recommandée

If the code is keeping for long time, please contact with your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37

Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.