14Fault

Felicity inverter error 14 (F14)

Output voltage high

Also displayed as F14 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

IVPS/IVPM Series

InverterFault

Also applies to:IVPS2512IVPS2524IVPS3524IVPS5024IVPS5048IVPS7548IVPS-7548IVPS10048+9

What it means

Output voltage highThe inverter output voltage is above the allowed range.

Cause: The inverter measured its own AC output voltage above the permitted range. Output voltage is regulated entirely inside the unit, so this points to an internal regulation or feedback fault rather than a wiring issue.

How to fix it

  1. Restart the inverter.
  2. If the fault persists, contact the repair center.

Source: IVPS-IVPM User Guide.pdf, p.17 · IVPS3524P1G1-LV IVPS5048P1G1-LV IVPS7548P2G1 IVPS10048P2G1 User Guide - EN.pdf, p.24

T-REX-3KLP1G01

InverterFault

Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01

What it means

BuckBoost is out of balance

Cause: The buck-boost converter stage has drifted out of balance — its internal operating points are no longer matched, which is an internal converter fault rather than a wiring issue.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.37

IVEM 6048

InverterFault

Also applies to:IVEM6048

What it means

Short circuited happen at PV port

Cause: Wiring issue causing short at PV port.

How to fix it

Check if wiring is connected well.

Source: felicitysolar IVEM 6048 Solar Inverter User Guide.pdf, p.37

IVEM8048-II

InverterFault

Also applies to:IVEM12048-IIIVEM 8K-12K Series II

What it means

Short circuited happen at PV port

Cause: Short circuit detected at the PV input port or wiring.

How to fix it

Check if wiring is connected well.

Source: IVEM8K-12K-II_compressed.pdf, p.43

IVEM8048-LV

InverterFault

Also applies to:IVEM8048

What it means

Short circuited happen at PV port

Cause: Wiring not connected well.

How to fix it

Check if wiring is connected well.

Source: FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf, p.38

T-REX-50KHP3G01

InverterFault

What it means

Battery 1 software overvoltage faultBattery 1 voltage is too high, the battery should be discharged.

Cause: The control firmware measured battery 1 voltage above the protection limit — the pack is overcharged or its configuration exceeds the inverter's battery range, and it should be discharged.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.46

Apollo-5KLP1G01-MX

Energy storage systemCritical

Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2

What it means

BuckBoost is out of balanceBuckBoost converter is out of balance.

Cause: BuckBoost is out of balance.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.43

LUX-S-1600LG01

BatteryFault

What it means

PV1 voltage is too highFault event: PV input 1 voltage too high. Maximum allowed PV input voltage is 60Vdc; max PV voltage rating is 95V.

Cause: A fault has been detected in the PV input stage — usually a short, ground fault, or isolation failure between the PV array and the inverter chassis. Wet connectors, damaged cable insulation, or moisture in a junction box are common causes.

How to fix it

  1. Please check the voltage of the solar panel; it should be less than 95V.
  2. If the voltage is OK, please contact your installer.

Source: LUX-S-1600LG01.pdf, p.22

LUX-X-96050HG01

BatteryCritical

Also applies to:LUX-X-96050HMG01LUX-X-96050HCG01

What it means

Low Output ImpedanceOutput impedance is too low (possible short-circuit or bus fault detected).

Cause: Suspected short-circuit on output bus or precharge fault.

How to fix it

Restart, if the fault still exists, contact our engineer.

Source: LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf, p.21

LUX-Y-48100HG01

BatteryFault

Also applies to:LUX-Y-48100HCG01LUX-Y-48100HMG01LUX-Y-48100HR13G01LUX-Y-48100HR9G01

What it means

Low Output ImpedanceOutput impedance below the expected threshold.

Cause: Suspected short circuit on the output bus or a pre-charge fault.

How to fix it

Restart, if the fault still exists, contact our engineer.

Source: LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf, p.20

LUX-Y-48100HG01MN

BatteryFault

What it means

Low Output Impedance

Cause: Suspected short circuit on the output bus or a pre-charge fault.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf, p.27

Frequently asked questions

What does error 14 mean on a Felicity inverter?
It depends on the model — 12 devices use code 14. On the IVPS/IVPM Series it means: Output voltage high. The card for each model on this page gives its exact meaning and fix.
Is error 14 a fault or a warning?
14 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 14?
Restart the inverter. If the fault persists, contact the repair center. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.