Also applies to:IVPS2512IVPS2524IVPS3524IVPS5024IVPS5048IVPS7548IVPS-7548IVPS10048+9
What it means
Output voltage high — The inverter output voltage is above the allowed range.
Cause: The inverter measured its own AC output voltage above the permitted range. Output voltage is regulated entirely inside the unit, so this points to an internal regulation or feedback fault rather than a wiring issue.
How to fix it
- Restart the inverter.
- If the fault persists, contact the repair center.
Source: IVPS-IVPM User Guide.pdf, p.17 · IVPS3524P1G1-LV IVPS5048P1G1-LV IVPS7548P2G1 IVPS10048P2G1 User Guide - EN.pdf, p.24