IVGM5KL-P1G1

Inverter61 codes
also coversIVGM6KL-P1G1IVGM7K6L-P1G1IVGM8KL-P1G1
61 Fault
05PV over current fault.Fault
Description

PV input over current fault.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
18Battery Under Voltage Alarm.Fault
Description

Battery voltage is too low, the battery should be charged.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 51Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
19Battery Open Circuit Alarm.Fault
Description

Battery open, check battery wiring.

Recommended fix

Check battery wiring.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 51
20Battery SOC Low Alarm.Fault
Description

Battery SOC is too low, battery should be recharged.

Recommended fix

Recharge the battery.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 51
21BMS communication Alarm.Fault
Description

Abnormal communication between battery and inverter in non-SOC mode, check battery and inverter wiring.

Recommended fix

Check battery and inverter wiring.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 51
22Battery Under Voltage Alarm or Battery SOC Low Alarm.Fault
Description

Battery voltage is too low or Battery SOC is too low, the battery should be charged.

Recommended fix

Charge the battery.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 51
25Battery over voltage fault.Fault
Description

Battery voltage exceeds specification.

Recommended fix

1. Check the Battery voltage is in the range of standard voltage in specification; 2. Check whether Battery cables are firmly and correctly connected; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
27Battery over Current fault.Fault
Description

Battery over current fault.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
28Bat hardware overcurrent.Fault
Description

Battery hardware over current detected.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
31LLC over Current fault of hardware.Fault
Description

LLC converter hardware over current fault.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
32BMS communication fault.Fault
Description

BMS communication failure between battery and inverter.

Recommended fix

1. Check whether BMS communication cable is firmly and correctly connected; 2. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
33Grid Over Voltage Alarm.Fault
Description

Grid voltage is too high, check if the grid voltage is within the normal range.

Recommended fix

Check if the grid voltage is within the normal range.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 51
34Grid Under Voltage Alarm.Fault
Description

Grid voltage is too low, check if the grid voltage is within the normal range.

Recommended fix

Check if the grid voltage is within the normal range.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 51
35BUCK-BOOST Current sensor fault.Fault
Description

Grid frequency is too high, check if the grid frequency is within the normal range.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 51Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
36Grid Under Frequency Alarm.Fault
Description

Grid frequency is too low, check if the grid frequency is within the normal range.

Recommended fix

Check if the grid frequency is within the normal range.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 51
37LLC soft start failure.Fault
Description

LLC converter soft start failure.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
38Grid Reverse Sequence Alarm.Fault
Description

Grid phase sequence reversed, check grid phase sequence wiring.

Recommended fix

Check grid phase sequence wiring.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52
40BAT short circuit.Fault
Description

Battery port short circuit detected.

Recommended fix

1. Check whether the battery port is in short circuit; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
41BUS over voltage fault.Fault
Description

DC bus over voltage fault.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
43BUS under voltage fault.Fault
Description

When the power grid experiences an AC power outage, the device detects islanding proactively.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
44BUS voltage unbalance fault.Fault
Description

Entering LVRT at grid connection, the inverter absorbs reactive power from the grid.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
48Buckup Overload Alarm.Fault
Description

The load is overloaded and should be reduced.

Recommended fix

Reduce backup load.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52
49INV over Current of software.Fault
Description

Inverter software over current fault.

Recommended fix

1. Please check whether the load power is within the range; 2. Restart and check whether it is in normal; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
50INV over Current of hardware.Fault
Description

Inverter hardware over current fault.

Recommended fix

1. Please check whether the load power is within the range; 2. Restart and check whether it is in normal; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
51INV soft start failure.Fault
Description

Inverter soft start failure.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
52AC voltage DC component fault.Fault
Description

DC component detected in AC voltage output.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
53AC current DC component fault.Fault
Description

DC component detected in AC current output.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
54INV over voltage fault.Fault
Description

Inverter over voltage fault.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
55INV under voltage fault.Fault
Description

Inverter under voltage fault.

Recommended fix

1. Please check whether the load power is within the range; 2. Restart and check whether it is in normal; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
56INV short circuit fault.Fault
Description

Inverter output short circuit fault.

Recommended fix

1. Please check the connection of buckup is firmly and correctly; 2. Restart and check whether it is in normal; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
57Gen Over Voltage Alarm.Fault
Description

Generator voltage is too high, check whether the generator voltage is within the normal range.

Recommended fix

1. Please check whether the load power is within the range; 2. Restart and check whether it is in normal; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
58Gen Under Voltage Alarm.Fault
Description

Generator voltage is too low, check whether the generator voltage is within the normal range.

Recommended fix

1. Please check whether the load power is within the range; 2. Restart and check whether it is in normal; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
59Gen Over Frequency Alarm.Fault
Description

Generator frequency is too high, check whether the generator frequency is within the normal range.

Recommended fix

Check generator output frequency.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52
60Gen Under Frequency Alarm.Fault
Description

Generator frequency is too low, check whether the generator frequency is within the normal range.

Recommended fix

Check generator output frequency.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52
62Gen Reverse Sequence Alarm.Fault
Description

Generator phase sequence reversed, check generator phase sequence wiring.

Recommended fix

Check generator phase sequence wiring.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52
65Heatsink high temperature fault.Fault
Description

Heatsink over-temperature fault.

Recommended fix

1. Check whether the work environment temperature is too high; 2. Turn off the inverter for 15mins and restart; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 54
67Main and auxiliary DSP communication fault.Fault
Description

Please check whether the load on backup port exceeds the generator specifications.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
68MCU communication fault.Fault
Description

MCU communication fault.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
69Eeprom fault.Fault
Description

EEPROM fault.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
70AC leakage current sensor fault.Fault
Description

AC leakage current sensor fault.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
71AC leakage current fault.Fault
Description

AC leakage current detected.

Recommended fix

1. Check PV side cable ground connection; 2. Restart the system 2~3 times; 3. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
72Grid Relay open circuit fault.Fault
Description

Grid relay open circuit detected during self-check.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
74INV Relay self check fault.Fault
Description

Inverter relay self-check fault.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
76GEN Relay self check fault.Fault
Description

Generator relay self-check fault.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
77PV Insulation Impedance fault.Fault
Description

PV insulation impedance is too low.

Recommended fix

1. Check the connection of PV panels and inverter is firmly and correctly; 2. Check whether the PE cable of inverter is connected to ground; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
78Grid wrong Connect to buckup.Fault
Description

Grid is incorrectly connected to backup port.

Recommended fix

1. Check whether Backup cables are firmly and correctly connected; 2. Restart the system 2~3 times; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
79Generator port is connected to the generator or Grid when the mode is the smart load mode.Fault
Description

Generator/Grid wrongly connected when smart load mode is set.

Recommended fix

1. Check whether GEN cables are firmly and correctly connected; 2. Restart the system 2~3 times; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
82NTC open circuit.Fault
Description

NTC temperature sensor open circuit.

Recommended fix

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
83Radiator over-temperature derating alarm.Fault
Description

The inverter will reduce power if the heat sink temperature is too high.

Recommended fix

Improve ventilation; reduce ambient temperature.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52
85External CT Sensor Fault.Fault
Description

External CT (current transformer) sensor fault.

Recommended fix

1. Check the connection of CT is firmly and correctly; 2. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 55
86System parameters change.Fault
Description

Grid setting or Bat setting change, and the system will restart after 20ms.

Recommended fix

Wait for system restart after parameter change.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56
87Fan2 Failed Alarm.Fault
Description

Fan 2 malfunction, check fan for proper functioning.

Recommended fix

1. Please check whether External RSD signal triggers shutdown; 2. if not, restart the inverter; 3. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56
88Parallel system error.Fault
Description

Parallel system error.

Recommended fix

1. Please check whether other inverter is in error state; 2. Restart the system; 3. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56
89Parallel Can Communication failure.Fault
Description

Parallel CAN communication failure.

Recommended fix

1. Check whether Parallel cables are firmly and correctly connected; 2. Restart the system 2~3 times; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56
90Parallel Host Lost.Fault
Description

Parallel host inverter lost.

Recommended fix

1. Check whether Parallel cables are firmly and correctly connected; 2. Restart the system 2~3 times; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56
91Push-button shutdown alarm.Fault
Description

Parallel synchronization signal lost.

Recommended fix

1. Check whether Parallel cables are firmly and correctly connected; 2. Restart the system 2~3 times; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56
92Parallel Version is inconsistent.Fault
Description

Parallel inverters have inconsistent software versions.

Recommended fix

1. Check whether the software version of the inverter is same; 2. Restart the system 2~3 times; 3. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56
93Parallel Setting is inconsistent.Fault
Description

Flash is not burned, contact the maintenance centre.

Recommended fix

1. Check whether Parallel cables are firmly and correctly connected; 2. Check whether the software version of the inverter is same; 3. Restart the system 2~3 times; 4. Seek help from us, if can not go back to normal state.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 52Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56
94CAN ID Conflict.Fault
Description

CAN ID of different inverters is in conflict.

Recommended fix

1. Please check whether CAN ID of different inverters is same; 2. Please check whether there are two masters in one phase.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56
95Parallel PWM signal lost.Fault
Description

Parallel PWM signal lost.

Recommended fix

1. Please check whether the parallel cables are well-connected; 2. Restart the system; 3. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56
96Phase sequence abnormal.Fault
Description

Grid phase sequence is abnormal.

Recommended fix

1. Please check whether the grid wires are well-connected; 2. Please check whether the grid phase sequence is correct; 3. Restart the system; 4. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 56