87Warning

Felicity inverter error 87 (F87)

Faults for high temperature of built-in MPPT

Also displayed as F87 on some models.

Warningthe red LED flashes and the inverter keeps running. Deal with it before it escalates.

Severity differs by model — check your model below.

The exact meaning depends on your model:

IVPS/IVPM Series

InverterWarning

Also applies to:IVPS2512IVPS2524IVPS3524IVPS5024IVPS5048IVPS7548IVPS-7548IVPS10048+3

What it means

Faults for high temperature of built-in MPPTThe built-in MPPT charge controller reports high temperature.

Cause: The built-in MPPT charge controller has overheated.

How to fix it

  1. Improve ventilation and let the unit cool down.
  2. If the warning persists, contact the repair center.

Source: IVPS-IVPM User Guide.pdf, p.18

IVGM5KL-P1G1

InverterFault

Also applies to:IVGM6KL-P1G1IVGM7K6L-P1G1IVGM8KL-P1G1

What it means

Fan2 Failed AlarmFan 2 malfunction, check fan for proper functioning.

Cause: Internal cooling fan failure detected. Often caused by dust buildup, bearing wear, or debris fouling the fan blades.

How to fix it

  1. Please check whether External RSD signal triggers shutdown
  2. If not, restart the inverter
  3. If the fault still exists, please contact us for help.

Source: Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf, p.52 · Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf, p.56

T-REX-3KLP1G01

InverterFault

Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01T-REX-10KHP3G01

What it means

Battery input circuit failure

Cause: The battery input circuit failed its self-check — the path between the battery terminals and the internal DC stage is not behaving as expected, which points to an internal fault rather than the battery itself.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.39 · T-REX-10KHP3G01-Inverter-User-Guide.pdf, p.29

T-REX-10KLP3G01

InverterCritical

What it means

Battery input circuit failure

Cause: The battery input circuit failed its self-check — the path between the battery terminals and the internal DC stage is not behaving as expected, which points to an internal fault rather than the battery itself.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: T-REX-10KLP3G01-Inverter-User-Guide.pdf, p.29

T-REX-50KHP3G01

InverterFault

What it means

Parallel CAN communicationThe inverter is connected to abnormal parallel communication.

Cause: Communication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.

How to fix it

  1. Verify the communication cable (CAN/RS485/Modbus) is correctly seated and the right pinout is used.
  2. Check baud rate and protocol settings in both devices match.
  3. Reseat the dongle/comms module.
  4. For BMS comms, confirm the battery is powered on and not in deep-discharge protection.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.48

Apollo-5KLP1G01-MX

Energy storage systemCritical

Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2

What it means

Battery input circuit failure

Cause: Battery input circuit failure.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.44

Frequently asked questions

What does error 87 mean on a Felicity inverter?
It depends on the model — 7 devices use code 87. On the IVPS/IVPM Series it means: Faults for high temperature of built-in MPPT. The card for each model on this page gives its exact meaning and fix.
Is error 87 a fault or a warning?
It depends on the model: on some models 87 is a fault (output cut, red LED solid), on others a warning (red LED flashing, unit keeps running). Check the card for your model on this page.
How do I clear or fix error 87?
Improve ventilation and let the unit cool down. If the warning persists, contact the repair center. The exact steps for each affected model are listed on this page.