95Fault

Felicity inverter error 95

Parallel PWM signal lost

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

IVGM5KL-P1G1

InverterFault

Also applies to:IVGM6KL-P1G1IVGM7K6L-P1G1IVGM8KL-P1G1

What it means

Parallel PWM signal lost

Cause: The hardware PWM synchronization signal shared between paralleled units has dropped out — almost always a parallel cable that is loose, damaged, or wrongly seated.

How to fix it

  1. Please check whether the parallel cables are well-connected
  2. Restart the system
  3. If the fault still exists, please contact us for help.

Source: Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf, p.56

Frequently asked questions

What does error 95 mean on a Felicity inverter?
95 means: Parallel PWM signal lost. The hardware PWM synchronization signal shared between paralleled units has dropped out — almost always a parallel cable that is loose, damaged, or wrongly seated.
Is error 95 a fault or a warning?
95 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 95?
1. Please check whether the parallel cables are well-connected; 2.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.