93Fault

Felicity inverter error 93 (F93)

Parallel Setting is inconsistent

Also displayed as F93 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

IVGM5KL-P1G1

InverterFault

Also applies to:IVGM6KL-P1G1IVGM7K6L-P1G1IVGM8KL-P1G1

What it means

Parallel Setting is inconsistentFlash is not burned, contact the maintenance centre.

Cause: The inverters in the parallel group are not running identical parallel settings, so the group cannot form. The related fault-table entry covers a control board whose firmware flash was never programmed, which needs the maintenance centre.

How to fix it

  1. Check whether Parallel cables are firmly and correctly connected
  2. Check whether the software version of the inverter is same
  3. Restart the system 2~3 times
  4. Seek help from us, if can not go back to normal state.

Source: Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf, p.52 · Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf, p.56

T-REX-50KHP3G01

InverterFault

What it means

BMS2 communication failureBMS2 fails to communicate normally, check the BMS2 communication cable.

Cause: Communication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.

How to fix it

  1. Verify the communication cable (CAN/RS485/Modbus) is correctly seated and the right pinout is used.
  2. Check baud rate and protocol settings in both devices match.
  3. Reseat the dongle/comms module.
  4. For BMS comms, confirm the battery is powered on and not in deep-discharge protection.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.49

Frequently asked questions

What does error 93 mean on a Felicity inverter?
It depends on the model — 2 devices use code 93. On the IVGM5KL-P1G1 it means: Parallel Setting is inconsistent. The card for each model on this page gives its exact meaning and fix.
Is error 93 a fault or a warning?
93 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 93?
1. Check whether Parallel cables are firmly and correctly connected; 2. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.