88Warning

Felicity inverter error 88 (F88)

Faults for PV over voltage of built-in MPPT

Also displayed as F88 on some models.

Warningthe red LED flashes and the inverter keeps running. Deal with it before it escalates.

Severity differs by model — check your model below.

The exact meaning depends on your model:

IVPS/IVPM Series

InverterWarning

Also applies to:IVPS2512IVPS2524IVPS3524IVPS5024IVPS5048IVPS7548IVPS-7548IVPS10048+3

What it means

Faults for PV over voltage of built-in MPPTThe built-in MPPT charge controller reports PV over voltage.

Cause: The PV input voltage to the built-in MPPT charge controller is too high.

How to fix it

  1. Reduce the number of PV modules in series so the PV voltage stays within the allowed range.
  2. If the warning persists, contact the repair center.

Source: IVPS-IVPM User Guide.pdf, p.18

IVGM5KL-P1G1

InverterFault

Also applies to:IVGM6KL-P1G1IVGM7K6L-P1G1IVGM8KL-P1G1

What it means

Parallel system error

Cause: Another inverter in the parallel group is in a fault state, so the whole group reports a system-level error until that unit recovers.

How to fix it

  1. Please check whether other inverter is in error state
  2. Restart the system
  3. If the fault still exists, please contact us for help.

Source: Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf, p.56

T-REX-50KHP3G01

InverterFault

What it means

Parallel host loss faultParallel host disconnects from the system, check whether the hosts is normal.

Cause: The parallel host (master) inverter has disconnected from the system, so the group has lost its coordinating unit until the host is restored.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.49

Frequently asked questions

What does error 88 mean on a Felicity inverter?
It depends on the model — 3 devices use code 88. On the IVPS/IVPM Series it means: Faults for PV over voltage of built-in MPPT. The card for each model on this page gives its exact meaning and fix.
Is error 88 a fault or a warning?
It depends on the model: on some models 88 is a fault (output cut, red LED solid), on others a warning (red LED flashing, unit keeps running). Check the card for your model on this page.
How do I clear or fix error 88?
Reduce the number of PV modules in series so the PV voltage stays within the allowed range. If the warning persists, contact the repair center. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.