Felicity T-REX-10KLP3G01 Error Codes: Causes & Fixes (48 codes)

This is the complete fault table for the Felicity T-REX-10KLP3G01 Inverter — all 48 codes from the official manual on one page. On Felicity units, a fault code means the unit has cut its output and the red LED stays solid; a warning flashes the red LED while the unit keeps running.

Last checked against the official manuals on July 10, 2026.

How to read the severity labels

  • Critical(10)unit trips offline — do not restart before checking
  • Fault(32)output stops · red LED solid
  • Warning(6)unit keeps running · red LED flashing

Critical codes (10)unit trips offline — do not restart before checking

F04Critical

Short circuit happen at PV port.

Critical

CauseA short circuit was detected at the PV input — the array wiring presents a near-zero-resistance path, so the input stage shut down.

Recommended fixCheck if wiring is connect well.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

F19Critical

Output short circuited.

Critical

CauseWiring fault or abnormal load on the output.

Recommended fixCheck if wiring is connected well and remove abnormal load.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F26Critical

Invert soft start failed.

Critical

Inverter soft start failed.

CauseInternal components failed.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F31Critical

Bus voltage is too high.

Critical

CauseAC Surge or internal components failed.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F33Critical

Bus soft start failed.

Critical

CauseInternal components failed.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F38Critical

Leakage current fault.

Critical

CauseGround leakage current above the safety limit was detected — insulation or grounding on the PV or AC side is letting current return outside the normal conductors.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F40Critical

Isolation resistance to ground of the PV string is too low.

Critical

CauseA fault has been detected in the PV input stage — usually a short, ground fault, or isolation failure between the PV array and the inverter chassis. Wet connectors, damaged cable insulation, or moisture in a junction box are common causes.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F41Critical

Grounding errors.

Critical

CauseThe inverter's ground check failed — the PE/earth connection is missing, high-impedance, or wired incorrectly, so protective earthing cannot be guaranteed.

Recommended fix1. Confirm correct grounding. 2. Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F50Critical

EEPROM failure.

Critical

CauseA read/write error occurred in the EEPROM that stores the inverter's settings and calibration, so the control board cannot reliably save or recall its configuration.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F87Critical

Battery input circuit failure.

Critical

CauseThe battery input circuit failed its self-check — the path between the battery terminals and the internal DC stage is not behaving as expected, which points to an internal fault rather than the battery itself.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

Fault codes (32)output stops · red LED solid

F01Fault

PV voltage is too high.

Fault

CausePV input voltage exceeds inverter limits (too many PV modules in series).

Recommended fixReduce the number of PV modules in series.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

F02Fault

Over current happen at PV port.

Fault

CauseCurrent from the PV array exceeded the input stage's protection limit, so the inverter shut the PV input down.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

F07Fault

Battery voltage is too high.

Fault

CauseBattery specification or quantity does not meet requirements.

Recommended fixCheck if spec and quantity of batteries are meet requirements.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

F08Fault

Over current happen at Battery.

Fault

CauseCurrent into or out of the battery exceeded the protection limit — a charge or discharge surge beyond what the battery stage is rated for.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

F11Fault

Over current happen at Buckboost.

Fault

CauseThe buck-boost converter stage drew current above its protection limit.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

F13Fault

Buckboost soft start failed.

Fault

CauseThe buck-boost stage failed to ramp to its working point during soft start — an internal converter fault rather than a wiring issue.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

F15Fault

Buckboost current sensor failed.

Fault

CauseThe buck-boost current sensor returned an out-of-range or implausible reading, so the control board can no longer trust that stage's current measurement.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

F17Fault

Overload time out.

Fault

CauseConnected load is too high.

Recommended fixReduce the connected load by switching off some equipment.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F18Fault

The output overcurrent is abnormal.

Fault

CauseThe inverter's output current ran above the protection limit — an overload or surge on the connected loads, or a fault in the output stage's current control.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F21Fault

OP current sensor failed.

Fault

Output current sensor failed.

CauseOutput current sensor failed.

Recommended fixOutput current sensor failed.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F22Fault

Output voltage is too low.

Fault

CauseConnected load is too high.

Recommended fixReduce the connected load.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F23Fault

Output voltage is too high.

Fault

CauseThe inverter measured its own AC output voltage above the permitted range — an internal regulation fault rather than a wiring issue.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F24Fault

Over current or surge detected by Software.

Fault

CauseThe control software measured a current or surge on the power stage beyond its protection limit. The software trip catches sustained overcurrent, as opposed to the instantaneous hardware trip of F25.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F25Fault

Hardware detect over current at inverter port.

Fault

CauseA hardware protection circuit tripped on overcurrent at the inverter port. It acts independently of the firmware and reacts to fast transients such as load inrush or a surge.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F28Fault

The DC component of the inverter current is abnormal.

Fault

CauseThe DC component riding on the inverter's output current exceeded the permitted limit — the output waveform has developed an asymmetry, typically from an output-stage or current-feedback fault.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F29Fault

Inverter current sensor failed.

Fault

CauseThe inverter-stage current sensor returned an out-of-range or implausible reading, so the control board can no longer trust its inverter current measurement.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F30Fault

Bus voltage is too low.

Fault

CauseThe internal DC bus voltage fell below its operating range. The bus is regulated entirely inside the unit, so a persistent low reading points to an internal conversion-stage fault rather than external wiring.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F32Fault

Bus voltage unbalance.

Fault

CauseThe positive and negative halves of the internal DC bus have drifted apart in voltage — an internal balancing fault in the conversion stages.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F34Fault

Over temperature happen at heat sink.

Fault

CauseAmbient temperature is too high.

Recommended fixCheck whether the ambient temperature is too high.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F35Fault

The inner temperature over.

Fault

The inner temperature is too high.

CauseAmbient temperature is too high.

Recommended fixCheck whether the ambient temperature is too high.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F39Fault

Leakage current sensor failed.

Fault

CauseThe leakage current sensor returned an out-of-range or implausible reading, so the inverter can no longer verify that its leakage protection is working.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 28

F42Fault

Relay check failure.

Fault

CauseA safety relay inside the inverter has failed self-test or is stuck. The inverter is designed to refuse grid connection in this state, so this is not an issue you can clear with restart cycles.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F43Fault

CAN data loss.

Fault

CauseCommunication cables not connected well.

Recommended fix1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F44Fault

Host data loss.

Fault

CauseCommunication cables not connected well.

Recommended fix1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F45Fault

Synchronization data loss.

Fault

CauseCommunication cables not connected well.

Recommended fix1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F46Fault

The firmware version of each inverter is not the same.

Fault

CauseInverter firmware versions are mismatched across parallel units.

Recommended fix1. Update all inverter firmware to the same version. 2. Check the version of each inverter via LCD setting and make sure the CPU versions are same. if not, please contact your installer to provide the firmware to update. 3. After updating, if the problem still remains, please contact your installer.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F47Fault

The inverter Settings are inconsistent.

Fault

CauseParallel inverter settings differ between units.

Recommended fix1. Through the LCD control button on the inverter, the parameters of the machine are set to the same as those of other machines. 2. if the problem persists, contact the after-sales service.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F48Fault

Parallel installation is abnormal.

Fault

CauseThe parallel bus detects an installation that does not form a valid group — wrong cabling topology or an inconsistent set of units — so the system will not start.

Recommended fixContact after-sales service for installation technical guidance.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F49Fault

Parallel negative power protection.

Fault

CauseOne unit in the parallel group was detected absorbing power from the others (negative power flow), which the protection treats as a load-sharing fault and shuts down.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F51Fault

DSP1 communication failure.

Fault

CauseCommunication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F52Fault

DSP2 communication failure.

Fault

CauseCommunication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

F91Fault

The number of battery packs in series has not been set.

Fault

CauseThe number of battery packs in series has not been set.

Recommended fixPlease set it correctly according to the number of battery packs used by the inverter.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 29

Warning codes (6)unit keeps running · red LED flashing

W07Warning

Low battery.

Warning

Low battery warning indicated on LCD with flashing fault LED.

CauseThe battery voltage is too low.

Recommended fixBattery should be charging.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

W09Warning

Overload.

Warning

Overload warning. Audible alarm: beep twice every second.

CauseThe connected load exceeds the inverter's continuous output rating; the buzzer beeps twice every second and protection will cut the output if the overload is not reduced.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

W51Warning

BMS doesn't allow inverter to discharge battery.

Warning

BMS does not allow the inverter to discharge battery; inverter will stop discharging battery automatically.

CauseBMS doesn't allow inverter to discharge battery.

Recommended fixInverter will stop discharging battery automatically.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

W52Warning

BMS require inverter to charge battery.

Warning

BMS requires inverter to charge battery; inverter will charge battery automatically.

CauseBMS require inverter to charge battery.

Recommended fixInverter will charge battery automatically.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

W60Warning

BMS firmware version is not matched.

Warning

CauseBMS firmware version is not matched.

Recommended fixUpgrade the firmware of BMS.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

W91Warning

The number of battery packs in series has not been set.

Warning

CauseThe number of battery packs in series has not been set.

Recommended fixPlease set it correctly according to the number of battery packs used by the inverter.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf· page 27

Still seeing a code on your T-REX-10KLP3G01?

Send us the code on your screen and a Felicity technician will reply with the exact steps for your unit. Support is free for life — a first diagnosis never needs a callout.

Keep troubleshooting

Related devices

Common questions about T-REX-10KLP3G01 error codes

What is the difference between a fault and a warning on the T-REX-10KLP3G01?
A fault cuts the unit's output and the red LED stays solid — this page lists 42 of them for the T-REX-10KLP3G01. A warning only flashes the red LED and the unit keeps running; there are 6 warning codes here. Resolve the cause of a fault before restarting; warnings can usually be cleared while the unit runs.
Does this page apply to other Felicity models?
No — this table was transcribed specifically from the T-REX-10KLP3G01 manual. Other Felicity devices have their own pages; start from the error-code hub to find the one matching the model number on your unit's label.
Where do these codes come from?
Every entry was transcribed from T-REX-10KLP3G01-Inverter-User-Guide.pdf — Felicity's official documentation. Each row cites its source manual (and page where printed), so you can verify the wording before acting on it.

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.