T-REX-10KLP3G01

Onduleur48 codes
10 Critique 32 Défaut 6 Avertissement
F01PV voltage is too high.Défaut
Description

PV voltage is too high.

Cause

PV input voltage exceeds inverter limits (too many PV modules in series).

Correction recommandée

Reduce the number of PV modules in series.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
F02Over current happen at PV port.Défaut
Description

Over current happen at PV port.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
F04Short circuit happen at PV port.Critique
Description

Short circuit happen at PV port.

Correction recommandée

Check if wiring is connect well.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
F07Battery voltage is too high.Défaut
Description

Battery voltage is too high.

Cause

Battery specification or quantity does not meet requirements.

Correction recommandée

Check if spec and quantity of batteries are meet requirements.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
F08Over current happen at Battery.Défaut
Description

Over current happen at Battery.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
F11Over current happen at Buckboost.Défaut
Description

Over current happen at Buckboost.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
F13Buckboost soft start failed.Défaut
Description

Buckboost soft start failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
F15Buckboost current sensor failed.Défaut
Description

Buckboost current sensor failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
F17Overload time out.Défaut
Description

Overload time out.

Cause

Connected load is too high.

Correction recommandée

Reduce the connected load by switching off some equipment.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F18The output overcurrent is abnormal.Défaut
Description

The output overcurrent is abnormal.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F19Output short circuited.Critique
Description

Output short circuited.

Cause

Wiring fault or abnormal load on the output.

Correction recommandée

Check if wiring is connected well and remove abnormal load.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F21OP current sensor failed.Défaut
Description

Output current sensor failed.

Cause

Output current sensor failed.

Correction recommandée

Output current sensor failed.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F22Output voltage is too low.Défaut
Description

Output voltage is too low.

Cause

Connected load is too high.

Correction recommandée

Reduce the connected load.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F23Output voltage is too high.Défaut
Description

Output voltage is too high.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F24Over current or surge detected by Software.Défaut
Description

Over current or surge detected by Software.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F25Hardware detect over current at inverter port.Défaut
Description

Hardware detect over current at inverter port.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F26Invert soft start failed.Critique
Description

Inverter soft start failed.

Cause

Internal components failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F28The DC component of the inverter current is abnormal.Défaut
Description

The DC component of the inverter current is abnormal.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F29Inverter current sensor failed.Défaut
Description

Inverter current sensor failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F30Bus voltage is too low.Défaut
Description

Bus voltage is too low.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F31Bus voltage is too high.Critique
Description

Bus voltage is too high.

Cause

AC Surge or internal components failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F32Bus voltage unbalance.Défaut
Description

Bus voltage unbalance.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F33Bus soft start failed.Critique
Description

Bus soft start failed.

Cause

Internal components failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F34Over temperature happen at heat sink.Défaut
Description

Over temperature happen at heat sink.

Cause

Ambient temperature is too high.

Correction recommandée

Check whether the ambient temperature is too high.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F35The inner temperature over.Défaut
Description

The inner temperature is too high.

Cause

Ambient temperature is too high.

Correction recommandée

Check whether the ambient temperature is too high.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F38Leakage current fault.Critique
Description

Leakage current fault.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F39Leakage current sensor failed.Défaut
Description

Leakage current sensor failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F40Isolation resistance to ground of the PV string is too low.Critique
Description

Isolation resistance to ground of the PV string is too low.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F41Grounding errors.Critique
Description

Grounding errors.

Cause

Improper grounding.

Correction recommandée

1. Confirm correct grounding. 2. Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F42Relay check failure.Défaut
Description

Relay check failure.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F43CAN data loss.Défaut
Description

CAN data loss.

Cause

Communication cables not connected well.

Correction recommandée

1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F44Host data loss.Défaut
Description

Host data loss.

Cause

Communication cables not connected well.

Correction recommandée

1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F45Synchronization data loss.Défaut
Description

Synchronization data loss.

Cause

Communication cables not connected well.

Correction recommandée

1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F46The firmware version of each inverter is not the same.Défaut
Description

The firmware version of each inverter is not the same.

Cause

Inverter firmware versions are mismatched across parallel units.

Correction recommandée

1. Update all inverter firmware to the same version. 2. Check the version of each inverter via LCD setting and make sure the CPU versions are same. if not, please contact your installer to provide the firmware to update. 3. After updating, if the problem still remains, please contact your installer.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F47The inverter Settings are inconsistent.Défaut
Description

The inverter Settings are inconsistent.

Cause

Parallel inverter settings differ between units.

Correction recommandée

1. Through the LCD control button on the inverter, the parameters of the machine are set to the same as those of other machines. 2. if the problem persists, contact the after-sales service.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F48Parallel installation is abnormal.Défaut
Description

Parallel installation is abnormal.

Correction recommandée

Contact after-sales service for installation technical guidance.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F49Parallel negative power protection.Défaut
Description

Parallel negative power protection.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F50EEPROM failure.Critique
Description

EEPROM failure.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F51DSP1 communication failure.Défaut
Description

DSP1 communication failure.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F52DSP2 communication failure.Défaut
Description

DSP2 communication failure.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F87Battery input circuit failure.Critique
Description

Battery input circuit failure.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
F91The number of battery packs in series has not been set.Défaut
Description

The number of battery packs in series has not been set.

Cause

The number of battery packs in series has not been set.

Correction recommandée

Please set it correctly according to the number of battery packs used by the inverter.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29
W07Low battery.Avertissement
Description

Low battery warning indicated on LCD with flashing fault LED.

Cause

The battery voltage is too low.

Correction recommandée

Battery should be charging.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
W09Overload.Avertissement
Description

Overload warning. Audible alarm: beep twice every second.

Correction recommandée

Reduce the loads.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
W51BMS doesn't allow inverter to discharge battery.Avertissement
Description

BMS does not allow the inverter to discharge battery; inverter will stop discharging battery automatically.

Cause

BMS doesn't allow inverter to discharge battery.

Correction recommandée

Inverter will stop discharging battery automatically.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
W52BMS require inverter to charge battery.Avertissement
Description

BMS requires inverter to charge battery; inverter will charge battery automatically.

Cause

BMS require inverter to charge battery.

Correction recommandée

Inverter will charge battery automatically.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
W60BMS firmware version is not matched.Avertissement
Description

BMS firmware version is not matched.

Cause

BMS firmware version is not matched.

Correction recommandée

Upgrade the firmware of BMS.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27
W91The number of battery packs in series has not been set.Avertissement
Description

The number of battery packs in series has not been set.

Cause

The number of battery packs in series has not been set.

Correction recommandée

Please set it correctly according to the number of battery packs used by the inverter.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27

Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.