47Fault

Felicity inverter error 47 (F47)

Inconsistent parallel settings

Also displayed as F47 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

T-REX-3KLP1G01

InverterFault

Also applies to:T-REX-3K6LP1G01T-REX-4KLP1G01T-REX-4K6LP1G01T-REX-5KLP1G01T-REX-6KLP1G01

What it means

Inconsistent parallel settings

Cause: The parallel configuration is set up wrong across the group — typically a mix-up between single-phase parallel and three-phase group settings on the units.

How to fix it

Single-phase parallel system and group three-phase system setup error.

Source: T-REX-3_3.6_4_4.6_5_6KLP1G01-hybrid-inverter-user-guide-English.pdf, p.39

IVEM8048-II

InverterFault

Also applies to:IVEM12048-IIIVEM 8K-12K Series II

What it means

Generator current sensor failed

Cause: Generator current sensor failure.

How to fix it

Restart the unit, if the error persists, contact the repair center.

Source: IVEM8K-12K-II_compressed.pdf, p.45

T-REX-10KHP3G01

InverterFault

What it means

The inverter Settings are inconsistentInverter settings differ between parallel units.

Cause: Parallel inverter settings differ between units.

How to fix it

  1. Through the LCD control button on the inverter, the parameters of the machine are set to the same as those of other machines.
  2. If the problem persists, contact the after-sales service.

Source: T-REX-10KHP3G01-Inverter-User-Guide.pdf, p.29

T-REX-10KLP3G01

InverterFault

What it means

The inverter Settings are inconsistent

Cause: Parallel inverter settings differ between units.

How to fix it

  1. Through the LCD control button on the inverter, the parameters of the machine are set to the same as those of other machines
  2. If the problem persists, contact the after-sales service.

Source: T-REX-10KLP3G01-Inverter-User-Guide.pdf, p.29

T-REX-50KHP3G01

InverterFault

What it means

Inverter overcurrent faultInverter current is too high, check the given power and load size.

Cause: Inverter output current tripped the hardware overcurrent protection, which acts independently of the firmware — a fast surge from the load side or a fault in the output stage.

How to fix it

  1. Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
  2. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source: T-REX-50KHP3G01-user-manual-.pdf, p.47

Apollo-5KLP1G01-MX

Energy storage systemFault

Also applies to:Apollo-5KLP1G01-M1Apollo-5KLP1G01-M2Apollo-4K6LP1G01-MXApollo-4K6LP1G01-M1Apollo-4K6LP1G01-M2

What it means

Inconsistent parallel settingsInconsistent parallel settings; single-phase parallel system and group three-phase system setup error.

Cause: Single-phase parallel system and group three-phase system setup error.

How to fix it

Single-phase parallel system and group three-phase system setup error.

Source: Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf, p.44

Frequently asked questions

What does error 47 mean on a Felicity inverter?
It depends on the model — 6 devices use code 47. On the T-REX-3KLP1G01 it means: Inconsistent parallel settings. The card for each model on this page gives its exact meaning and fix.
Is error 47 a fault or a warning?
47 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 47?
Single-phase parallel system and group three-phase system setup error. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.