Felicity LUX-Y-48100HG01 Error Codes: Causes & Fixes (34 codes)

This is the complete fault table for the Felicity LUX-Y-48100HG01 Battery family — 34 codes shared by 5 model numbers, transcribed from the official manual. On this Felicity device, a fault code means the unit has entered protection and stopped normal operation; a warning leaves it running. The exact indication (LED pattern or display code) is listed per code below.

Also coversLUX-Y-48100HCG01LUX-Y-48100HMG01LUX-Y-48100HR13G01LUX-Y-48100HR9G01

Last checked against the official manuals on July 10, 2026.

How to read the severity labels

  • Critical(5)unit trips offline — do not restart before checking
  • Fault(10)operation stops until cleared
  • Warning(19)unit keeps running · needs attention

Critical codes (5)unit trips offline — do not restart before checking

18Critical

Relay Adhesion Fault.

Critical

Main relay contacts have welded/stuck (relay adhesion).

CauseA safety relay inside the inverter has failed self-test or is stuck. The inverter is designed to refuse grid connection in this state, so this is not an issue you can clear with restart cycles.

Recommended fixRestart, if the fault still exists, contact our engineer.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

BAT_PROT_INTERNAL_SHORT_CIRCUITCritical

Battery Internal Short Circuit Protection.

Critical

Battery protection: Internal short circuit detected.

CauseThe BMS detected a short circuit inside the battery pack and disconnected the output.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

INV_PROT_EXTERNAL_SHORT_CIRCUITCritical

External Short Circuit Protection.

Critical

Inverter interface protection: External short circuit detected.

CauseA short circuit was detected on the external, inverter-side wiring or connection.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

INV_PROT_REVERSE_POLARITY_GROUND_FAULTCritical

Reverse Polarity Ground Fault Protection.

Critical

Inverter interface protection: Reverse polarity ground fault detected.

CauseReverse polarity or a ground fault was detected on the inverter-side wiring.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

TS_LCD_NO_DISPLAYCritical

LCD Does Not Light Up or Flash.

Critical

Battery system cannot work; when DC switch on and POWER on, the LCD doesn't light up or flash.

CauseBattery system failure preventing power-up.

Recommended fixPlease consider contact the local distributor.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 21

Fault codes (10)operation stops until cleared

11Fault

AFE Fault.

Fault

Analog Front End (AFE) measurement fault detected by the BMS.

CauseInternal BMS measurement IC (AFE) malfunction.

Recommended fixRestart, if the fault still exists, contact our engineer.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

12Fault

Soft Start Failed.

Fault

Pre-charge / soft-start sequence failed during power-up.

CausePre-charge circuit failure, excessive inverter capacitance, or an external short on the output.

Recommended fixRestart, if the fault still exists, contact our engineer.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

13Fault

Slave Communication Failure.

Fault

Master-to-slave communication failure between BMS units.

CauseCommunication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.

Recommended fixCheck for poor contact of the communication line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

14Fault

Low Output Impedance.

Fault

Output impedance below the expected threshold.

CauseSuspected short circuit on the output bus or a pre-charge fault.

Recommended fixRestart, if the fault still exists, contact our engineer.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

15Fault

Slave Version Fault.

Fault

Slave BMS firmware version mismatch.

CauseSlave module firmware incompatible with the master controller.

Recommended fixContact our engineer to upgrade the program.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

16Fault

Slave Device Version Fault.

Fault

Slave device version fault.

CauseA slave device's firmware or protocol version does not match the master controller — the program must be upgraded before the system can run.

Recommended fixContact our engineer to upgrade the program.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

17Fault

Parallel Fault.

Fault

Fault in parallel battery configuration.

CauseA single unit is installed to a parallel system, the number of parallel battery slave controls does not match, or the wiring between paralleled units is incorrect.

Recommended fix1. Please check if the number of parallel battery slave controls is the same. 2. Please check if a single unit is installed in a parallel system. 3. if this error occurs during parallel installation, please check the wiring. if they are connected correctly, please install them in parallel first and then restart the device. 4. if the problem persists, please contact the installation personnel.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

ALARM_LEDFault

Alarm LED Lit.

Fault

Alarm LED indicates the fault status of the battery, which lights up when the fault occurs.

CauseA fault condition has been detected by the BMS (refer to Fault Code Table for specific code).

Recommended fixCheck LCD touch screen for the specific fault code and follow the corresponding treatment measure.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 18

TS_ALARM_ON_LCD_AND_INVERTERFault

Alarm Information on LCD and Inverter.

Fault

After the battery system is powered on, alarm information is displayed on the LCD and inverter display screen at the same time.

CauseAn active fault in the battery system that requires service intervention.

Recommended fixPlease contact the local distributor.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 21

TS_NO_SOC_ON_INVERTERFault

Cannot Charge/Discharge - No SOC on Inverter.

Fault

The LCD display of LUX-Y-48100HG01 is normal, but it cannot charge and discharge. Inverter display screen shows no SOC.

CauseCAN communication between LUX-Y-48100HG01 and inverter is not connected or cable is faulty.

Recommended fixCheck whether the CAN communication between LUX-Y-48100HG01 to inverter is well connected. if the connection is good, please replace a CAN communication cable. if the SOC is still not visible on the inverter display screen, please contact the local distributor.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 21

Warning codes (19)unit keeps running · needs attention

01Warning

High Battery Voltage.

Warning

Battery pack voltage exceeded the upper threshold.

CauseBattery pack overall voltage too high — an overcharge condition.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

02Warning

Low Battery Voltage.

Warning

Battery pack voltage fell below the lower threshold.

CauseBattery pack overall voltage too low — an over-discharge condition.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

03Warning

High Cell Voltage.

Warning

Individual cell voltage exceeded the upper threshold.

CauseCell-level overvoltage — imbalance or overcharge of a single cell.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

04Warning

Low Cell Voltage.

Warning

Individual cell voltage fell below the lower threshold.

CauseCell-level undervoltage — imbalance or deep discharge of a single cell.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

05Warning

High Charging Current.

Warning

Charging current exceeded the upper threshold.

CauseExcessive charging current from the inverter or charger.

Recommended fixReduce charging current.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

06Warning

High Discharging Current.

Warning

Discharging current exceeded the upper threshold.

CauseExcessive load current draw from the battery.

Recommended fixReduce discharging current.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

07Warning

High BMS Temperature.

Warning

BMS temperature is too high.

CauseBMS overheating due to high ambient temperature, poor ventilation, or high-current operation.

Recommended fixStop charging and discharging, wait for the temperature to drop.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

08Warning

Low BMS Temperature.

Warning

BMS temperature is too low.

CauseBMS too cold — ambient temperature below the operating range.

Recommended fixWait for temperature rise.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

09Warning

High Cell Temperature.

Warning

Cell temperature is too high.

CauseCell overheating due to high ambient temperature or high-current operation.

Recommended fixStop charging and discharging, wait for the temperature to drop.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

10Warning

Low Cell Temperature.

Warning

Cell temperature is too low.

CauseCell too cold — ambient temperature below the charge/discharge range.

Recommended fixWait for temperature rise.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 20

BAT_PROT_OVER_CURRENTWarning

Battery Over Current Protection.

Warning

Battery protection: Over current condition detected.

CauseCharge or discharge current exceeded the battery's protection limit, tripping the BMS over-current protection.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

BAT_PROT_OVER_TEMPWarning

Battery Over Temperature Protection.

Warning

Battery protection: Over temperature condition detected.

CauseInverter internal temperature has exceeded the safe operating threshold. Causes include high ambient temperature, blocked cooling vents, failed cooling fan, or installation in direct sunlight.

Recommended fixPower down the inverter and let it cool. Inspect cooling vents and fan inlets for dust, leaves, or insect nests — clean with compressed air. Confirm the inverter is installed in a shaded, ventilated location with the manufacturer's required clearances on all sides. If the fan does not spin on restart, fan replacement is required.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

BAT_PROT_OVER_VOLTAGEWarning

Battery Over Voltage Protection.

Warning

Battery protection: Over voltage condition detected.

CauseThe BMS detected battery voltage above its protection limit (overcharge) and disconnected to protect the cells.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

BAT_PROT_UNDER_VOLTAGEWarning

Battery Under Voltage Protection.

Warning

Battery protection: Under voltage condition detected.

CauseThe BMS detected battery voltage below its protection limit (over-discharge) and disconnected to protect the cells.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

INV_PROT_INRUSH_CURRENTWarning

Inrush Current Protection.

Warning

Inverter interface protection: In rush current condition detected.

CauseA large inrush current was detected at the inverter interface — typically the surge when a connected inverter's input capacitors charge at connection.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

INV_PROT_OVER_CURRENTWarning

Inverter Interface Over Current Protection.

Warning

Inverter interface protection: Over current condition detected at inverter interface.

CauseCurrent at the inverter interface exceeded the protection limit — the inverter is drawing or feeding more current than the battery allows.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

INV_PROT_OVER_TEMPWarning

Inverter Interface Over Temperature Protection.

Warning

Inverter interface protection: Over temperature detected.

CauseInverter internal temperature has exceeded the safe operating threshold. Causes include high ambient temperature, blocked cooling vents, failed cooling fan, or installation in direct sunlight.

Recommended fixPower down the inverter and let it cool. Inspect cooling vents and fan inlets for dust, leaves, or insect nests — clean with compressed air. Confirm the inverter is installed in a shaded, ventilated location with the manufacturer's required clearances on all sides. If the fan does not spin on restart, fan replacement is required.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

INV_PROT_OVER_VOLTAGEWarning

Inverter Interface Over Voltage Protection.

Warning

Inverter interface protection: Over voltage condition detected at inverter interface.

CauseVoltage at the inverter interface exceeded the protection limit — usually a connected inverter or charger applying a voltage above the battery's allowed range.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 7

STATUS_LED_OFFWarning

Status LED Not On.

Warning

Status LED indicates the operating status of the battery, which is always on when running normally. if not on, battery is not running normally.

CauseBattery system is not in normal running state.

Recommended fixCheck power switch, breaker, and review LCD for fault information.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf· page 18

Still seeing a code on your LUX-Y-48100HG01?

Send us the code on your screen and a Felicity technician will reply with the exact steps for your unit. Support is free for life — a first diagnosis never needs a callout.

Keep troubleshooting

Related devices

Common questions about LUX-Y-48100HG01 error codes

What is the difference between a fault and a warning on the LUX-Y-48100HG01?
A fault puts the unit into protection and stops normal operation — this page lists 15 of them for the LUX-Y-48100HG01. A warning leaves the unit running; there are 19 warning codes here. Resolve the cause of a fault before restarting; warnings can usually be cleared while the unit runs.
Which model numbers does this page cover?
The LUX-Y-48100HG01 shares its firmware and fault table with 4 other model numbers: LUX-Y-48100HCG01, LUX-Y-48100HMG01, LUX-Y-48100HR13G01, LUX-Y-48100HR9G01. If your unit is any of these, every code on this page applies to it.
Where do these codes come from?
Every entry was transcribed from LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf — Felicity's official documentation. Each row cites its source manual (and page where printed), so you can verify the wording before acting on it.

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.