LUX-X-96050HG01

Battery33 codes
also coversLUX-X-96050HMG01LUX-X-96050HCG01
19 Critical 11 Warning 3 Info
01High Battery Voltage.Warning
Description

Battery pack voltage exceeds the upper threshold.

Cause

Battery pack overall voltage too high (overcharge condition).

Recommended fix

Stop charging.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
02Low Battery Voltage.Warning
Description

Battery pack voltage below the lower threshold.

Cause

Battery pack overall voltage too low (over-discharge condition).

Recommended fix

Stop discharging.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
03High Cell Voltage.Warning
Description

Individual cell voltage exceeds maximum allowed value.

Cause

Cell-level overvoltage (imbalance or overcharge of a single cell).

Recommended fix

Stop charging.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
04Low Cell Voltage.Warning
Description

Individual cell voltage below minimum allowed value.

Cause

Cell-level undervoltage (imbalance or deep discharge of a single cell).

Recommended fix

Stop discharging.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
05High Charging Current.Warning
Description

Charging current above safe limit.

Cause

Excessive charging current from inverter/charger.

Recommended fix

Reduce charging current.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
06High Discharging Current.Warning
Description

Discharging current above safe limit.

Cause

Excessive load current draw from the battery.

Recommended fix

Reduce discharging current.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
07High BMS Temperature.Warning
Description

BMS internal temperature has exceeded safe operating limit.

Cause

BMS overheating due to high ambient temperature, poor ventilation, or high current operation.

Recommended fix

Stop charging and discharging, wait for the temperature to drop.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
08Low BMS Temperature.Warning
Description

BMS internal temperature is below safe operating limit.

Cause

BMS too cold (ambient temperature below operating range).

Recommended fix

Wait for temperature rise.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
09High Cell Temperature.Warning
Description

Battery cell temperature has exceeded safe operating limit.

Cause

Cell overheating due to high ambient temperature or high current operation.

Recommended fix

Stop charging and discharging, wait for the temperature to drop.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
10Low Cell Temperature.Warning
Description

Battery cell temperature is below safe operating limit.

Cause

Cell too cold (ambient temperature below charge/discharge range).

Recommended fix

Wait for temperature rise.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
11AFE Fault.Critical
Description

Analog Front End (AFE) fault detected by the BMS.

Cause

Internal BMS measurement IC (AFE) malfunction.

Recommended fix

Restart, if the fault still exists, contact our engineer.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
12Soft Start Failed.Critical
Description

Pre-charge / soft-start sequence failed during system power-up.

Cause

Pre-charge circuit failure, excessive inverter capacitance, or external short on output.

Recommended fix

Restart, if the fault still exists, contact our engineer.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
13Slave Communication Failure.Critical
Description

Communication failure between the master controller and one or more slave battery modules.

Cause

Poor contact / loose or damaged inter-module communication cable.

Recommended fix

Check for poor contact of the communication line.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
14Low Output Impedance.Critical
Description

Output impedance is too low (possible short-circuit or bus fault detected).

Cause

Suspected short-circuit on output bus or precharge fault.

Recommended fix

Restart, if the fault still exists, contact our engineer.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
15Slave Version Fault.Critical
Description

Firmware version mismatch on one or more slave battery modules.

Cause

Slave module firmware incompatible with the master controller.

Recommended fix

Contact our engineer to upgrade the program.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
ALARM_LEDAlarm LED.Warning
Description

Indicates the fault status of the battery; lights up when a fault occurs.

Cause

Any active BMS fault condition (see fault codes 01-15).

Recommended fix

Check LCD fault message for detailed fault definition before troubleshooting; the alarm clears automatically once the triggering condition is removed.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 19
CHARGING_LEDCharging LED.Info
Description

Indicates the charging status of the battery; flashing indicates charging.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 19
PROT_BAT_INTERNAL_SHORTBattery Internal Short Circuit Protection.Critical
Description

Internal short circuit detected within the battery pack.

Cause

Internal cell or busbar short within the battery module.

Recommended fix

Stop using the battery immediately and contact FelicityESS service; do not charge or discharge a damaged battery.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
PROT_BAT_OVERCURRENTBattery Over Current Protection.Critical
Description

Battery over-current protection trip.

Cause

Charge or discharge current exceeded battery limit (max continuous 50A, peak 60A/15s).

Recommended fix

Reduce current; verify inverter is configured within recommended 25A continuous (max 50A) range.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
PROT_BAT_OVERTEMPBattery Over Temperature Protection.Critical
Description

Battery over-temperature protection trip.

Cause

Cell or pack temperature exceeded safe operating limit.

Recommended fix

Stop charging/discharging, allow battery to cool, ensure ambient is within Charge 0~+55C / Discharge -20C~+55C.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
PROT_BAT_OVERVOLTAGEBattery Over Voltage Protection.Critical
Description

Battery overall over-voltage protection trip.

Cause

Battery pack voltage exceeded safe maximum (overcharge).

Recommended fix

Stop charging; check inverter charge voltage settings (target 113.6V x N).

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
PROT_BAT_UNDERVOLTAGEBattery Under Voltage Protection.Critical
Description

Battery overall under-voltage protection trip.

Cause

Battery pack voltage dropped below safe minimum (over-discharge).

Recommended fix

Stop discharging; recharge battery promptly. Battery should be charged within 3 months of storage to avoid deep discharge.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
PROT_INV_EXT_SHORT_CIRCUITExternal Short Circuit Protection.Critical
Description

External short-circuit detected at the inverter interface.

Cause

Short circuit on the DC power cabling between battery and inverter.

Recommended fix

Power off system and inspect DC wiring and inverter for short circuit before re-energising.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
PROT_INV_INRUSH_CURRENTInrush Current Protection.Critical
Description

Inrush current protection trip when battery output is connected to inverter.

Cause

Excessive inrush current to inverter capacitors at startup (precharge issue).

Recommended fix

Restart the battery and inverter following correct power-on sequence; if persistent, contact service engineer.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
PROT_INV_OVERCURRENTInverter Interface Over Current Protection.Critical
Description

Inverter-side over-current protection trip on the battery interface.

Cause

Charge or discharge current at inverter interface exceeds limit.

Recommended fix

Reduce inverter charge/discharge current setpoint; verify cabling and load conditions.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
PROT_INV_OVERTEMPInverter Interface Over Temperature Protection.Critical
Description

Over-temperature protection at the inverter interface.

Cause

Battery interface / contactor temperature exceeded safe limit.

Recommended fix

Allow system to cool; verify ventilation and ambient temperature within specification (Charge 0~+55C / Discharge -20C~+55C).

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
PROT_INV_OVERVOLTAGEInverter Interface Over Voltage Protection.Critical
Description

Inverter-side over-voltage protection trip on the battery inverter interface.

Cause

Inverter or DC bus voltage exceeds safe value at the battery interface.

Recommended fix

Check inverter charge voltage settings and DC bus; ensure inverter compatibility and correct configuration.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
PROT_INV_REVERSE_POLARITY_GNDReverse Polarity Ground Fault.Critical
Description

Reverse polarity / ground fault detected on the inverter interface.

Cause

Battery (+) and (-) cables connected with reversed polarity to the inverter, or ground fault.

Recommended fix

Power off and verify polarity of DC cabling between battery and inverter; correct wiring before re-energising.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 7
STATUS_LEDStatus LED.Info
Description

Indicates the operating status of the battery; always on when running normally.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 19
TS_ALARM_ON_LCD_AND_INVERTERAlarm information shown on both LCD and inverter screen after power-on.Critical
Description

After the battery system is powered on, alarm information appears simultaneously on the LCD and inverter display screen.

Cause

Active fault in the battery system requiring service intervention.

Recommended fix

Contact the local distributor.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 22
TS_LCD_NO_LIGHTLCD does not light up or flash on power-on.Critical
Description

After DC switch on and POWER on, the LCD does not light up or flash; battery system cannot work.

Cause

Battery system internal fault preventing power-up.

Recommended fix

Contact the local distributor.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 22
TS_NO_SOC_AT_INVERTERLCD normal but cannot charge/discharge (no SOC at inverter).Critical
Description

LCD display of LUX-X-96050HCG01 is normal but battery cannot charge or discharge; inverter screen shows no SOC.

Cause

CAN communication failure between LUX-X-96050HCG01 and inverter.

Recommended fix

Check CAN communication between LUX-X-96050HCG01 and inverter; if connection is good, replace the CAN communication cable. if SOC is still not visible, contact the local distributor.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 22
WAITING_TO_CONNECTWaiting to Connect (LCD icon).Info
Description

LCD icon lights up to indicate that the battery is waiting to be connected and there is no output at this time. After entering normal working mode, this icon disappears.

Cause

Battery has not yet established connection / handshake with the inverter.

Recommended fix

Wait for the battery to enter normal working mode; if it persists, check CAN/RS485 communication wiring to the inverter.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 20

Compiled from official FelicityESS user manuals. Always consult your device manual and a qualified technician before performing repairs.