Felicity LUX-Y-48100HG01MN Error Codes: Causes & Fixes (18 codes)

This is the complete fault table for the Felicity LUX-Y-48100HG01MN Battery — all 18 codes from the official manual on one page. On this Felicity device, a fault code means the unit has entered protection and stopped normal operation; a warning leaves it running. The exact indication (LED pattern or display code) is listed per code below.

Last checked against the official manuals on July 10, 2026.

How to read the severity labels

  • Fault(18)operation stops until cleared

Fault codes (18)operation stops until cleared

01Fault

High Battery Voltage.

Fault

CauseBattery pack overall voltage too high — an overcharge condition.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

02Fault

Low Battery Voltage.

Fault

CauseBattery pack overall voltage too low — an over-discharge condition.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

03Fault

High Cell Voltage.

Fault

CauseCell-level overvoltage — imbalance or overcharge of a single cell.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

04Fault

Low Cell Voltage.

Fault

CauseCell-level undervoltage — imbalance or deep discharge of a single cell.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

05Fault

High Charging Current.

Fault

CauseExcessive charging current from the inverter or charger.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

06Fault

High Discharging Current.

Fault

CauseExcessive load current draw from the battery.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

07Fault

High BMS Temperature.

Fault

CauseBMS overheating due to high ambient temperature, poor ventilation, or high-current operation.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

08Fault

Low BMS Temperature.

Fault

CauseBMS too cold — ambient temperature below the operating range.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

09Fault

High Cell Temperature.

Fault

CauseCell overheating due to high ambient temperature or high-current operation.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

10Fault

Low Cell Temperature.

Fault

CauseCell too cold — ambient temperature below the charge/discharge range.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

11Fault

AFE Fault.

Fault

AFE (Analog Front End) fault.

CauseInternal BMS measurement IC (AFE) malfunction.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

12Fault

Soft Start Failed.

Fault

CausePre-charge circuit failure, excessive inverter capacitance, or an external short on the output.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

13Fault

Slave Communication Failure.

Fault

CauseCommunication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.

Recommended fixVerify the communication cable (CAN/RS485/Modbus) is correctly seated and the right pinout is used. Check baud rate and protocol settings in both devices match. Reseat the dongle/comms module. For BMS comms, confirm the battery is powered on and not in deep-discharge protection.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

14Fault

Low Output Impedance.

Fault

CauseSuspected short circuit on the output bus or a pre-charge fault.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

15Fault

Slave Version Fault.

Fault

CauseSlave module firmware incompatible with the master controller.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

16Fault

Slave Device Version Fault.

Fault

CauseA slave device's firmware or protocol version does not match the master controller — the program must be upgraded before the system can run.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

17Fault

Parallel Fault.

Fault

CauseA single unit is installed to a parallel system, the number of parallel battery slave controls does not match, or the wiring between paralleled units is incorrect.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

18Fault

Relay Adhesion Fault.

Fault

CauseA safety relay inside the inverter has failed self-test or is stuck. The inverter is designed to refuse grid connection in this state, so this is not an issue you can clear with restart cycles.

Recommended fixThis requires service — the relay assembly is not user-replaceable. Record the exact fault code and contact your installer or the manufacturer's service line. Do not bypass any safety interlock.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf· page 27

Still seeing a code on your LUX-Y-48100HG01MN?

Send us the code on your screen and a Felicity technician will reply with the exact steps for your unit. Support is free for life — a first diagnosis never needs a callout.

Keep troubleshooting

Related devices

Common questions about LUX-Y-48100HG01MN error codes

What is the difference between a fault and a warning on the LUX-Y-48100HG01MN?
A fault puts the unit into protection and stops normal operation — this page lists 18 of them for the LUX-Y-48100HG01MN. The LUX-Y-48100HG01MN manual defines no separate warning table — every listed code stops operation. Resolve the cause of a fault before restarting; warnings can usually be cleared while the unit runs.
Does this page apply to other Felicity models?
No — this table was transcribed specifically from the LUX-Y-48100HG01MN manual. Other Felicity devices have their own pages; start from the error-code hub to find the one matching the model number on your unit's label.
Where do these codes come from?
Every entry was transcribed from LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf — Felicity's official documentation. Each row cites its source manual (and page where printed), so you can verify the wording before acting on it.

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.