80 A charging from the grid
the IVPM10048 pushes 80 A of AC charge current into its 48 V bank, to 57.6 V boost and 54.4 V float

InvertersModel IVPM10048
Off-grid inverter-charger giving 8 kW (10 kVA apparent) of pure sine power at 220 V, with an 80 A utility charger and a 120 A solar charger for one 48 V bank.
What sets the IVPM10048 apart from the other 2 models in the family: Backup Rated Output Power 8 kW; Max AC Charge Current 80 A; Max Charging Current 80 A; Rated Apparent Output Power 10 kVA; Rated Output Power 8 kW; Gross Weight 67.7 kg; Net Weight 55.4 kg; Package Dimensions 670 x 470 x 355 mm.
In stock
the IVPM10048 pushes 80 A of AC charge current into its 48 V bank, to 57.6 V boost and 54.4 V float
6.6 kW maximum PV input power on one MPPT tracker, taken at up to 170 V
one string per tracker, sized to stay inside that window at 48 V nominal battery voltage
10 kVA apparent, single phase on L+N+PE at 50/60 Hz, output regulated to within 5%
maximum efficiency is 90%, and the unit carries 2x rated power for 5 seconds on motor starts
low-frequency transformer-based, intelligent air cooling, 0-40 °C operating, LCD and LED display
The Felicity Solar IVPM10048 is a single-phase off-grid inverter-charger rated 8 kW, 10 kVA apparent, at 220 V and 50/60 Hz, working from one 48 V battery bank. It refills that bank at up to 80 A from the utility and 120 A from solar, and accepts 6.6 kW of PV on a single MPPT tracker carrying one string. The tracker works between 65 and 145 V, with 170 V the maximum PV voltage. Battery voltage is followed across 42-63 V in three stages, boost constant current then boost constant voltage at 57.6 V then float at 54.4 V, with 61.0 V the maximum charging voltage; AGM, Flooded, Li-Ion and Self-Defined profiles are selectable on the one battery input, and a battery BMS links over RS485 while RS232 reports to a monitor. Line-mode efficiency is 95%, maximum efficiency 90%, and transfer between utility and battery takes 15 ms. The low-frequency transformer-based build weighs 55.4 kg net, holds 2x rated power for 5 seconds for motor starts, and is rated IP21 for indoor mounting from 0 to 40 °C. Up to 6 units run in parallel with batteries fitted. We are an authorised Felicity Solar distributor. Warranty: 2 Years.
Specifications last updated 7 August 2026
| AC Output Voltage | 220 V |
|---|---|
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 8 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 42-63 V |
| Bulk Charging Voltage | 57.6 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 54.4 V |
| High DC Input Recovery Voltage | 62 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 280 V |
| High Line Reconnect Voltage | 270 V |
| Input Voltage Range | 90-280 V |
| Input Voltage Range (UPS Mode) | 170-280 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | 95 % |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (<50% Load) | 43 V |
| Low DC Shutdown (>50% Load) | 42 V |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 90 V |
| Low Line Disconnect (UPS Mode) | 170 V |
| Low Line Reconnect (Appliance Mode) | 100 V |
| Low Line Reconnect (UPS Mode) | 180 V |
| Low-Battery Recovery (<50% Load) | 47 V |
| Low-Battery Recovery (>50% Load) | 46 V |
| MPPT Trackers | 1 |
| MPPT Voltage Range | 65-145 V |
| Max AC Charge Current | 80 A |
|---|---|
| Max AC Input Voltage | 280 V |
| Max AC Pass-Through Current | 63 A |
| Max Charging Current | 80 A |
| Max Charging Voltage | 61.0 V |
| Max Efficiency | 90 % |
| Max PV Input Power | 6.6 kW |
| Max PV Voltage | 170 V |
| Max Solar Charging Current | 120 A |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 220 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Air Switch Protection |
| Overload Trip Time (>105% Load) | 10 s |
| Overload Trip Time (>150% Load) | 5 s |
| PV Working Voltage Range | 65-145 V |
| Pass-Through Without Battery | No |
| Phase | Single Phase |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| Rated Apparent Output Power | 10 kVA |
| Rated Output Power | 8 kW |
| Short-Circuit Protection (Line Mode) | Air Switch Protection |
| Start-Up Voltage | 46 V |
| Strings per MPPT | 1 |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 15 ms |
| BMS Communication | RS485 |
|---|---|
| Communication Interface | RS232 |
| Display | LCD, LED |
| Gross Weight | 67.7 kg |
| Net Weight | 55.4 kg |
| Package Dimensions | 670 x 470 x 355 mm |
| Parallel Capability | 6 (battery required) |
| Topology | Low-Frequency (transformer-based) |
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | 0-40 °C |
| Storage Temperature | -15 to 60 °C |
Looking up an error code on this FelicityESS IVPS/IVPM Series? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →80 A. That is the maximum AC charge current of the IVPM10048 from the utility, and solar can add up to 120 A. Charging runs three stages, boost constant current, boost constant voltage at 57.6 V and float at 54.4 V, with 61.0 V the maximum charging voltage.
6.6 kW is the maximum PV input power. It arrives on one MPPT tracker with one string, so keep panel voltage under the 170 V maximum PV voltage and the working voltage inside the 65-145 V MPPT range. Solar charge current is capped at 120 A.
48 V nominal, tracked from 42 V to 63 V on a single battery input. AGM, Flooded, Li-Ion and Self-Defined profiles are all selectable, and a lithium BMS links over RS485. The inverter does not pass utility power through without a battery connected, so the bank is required, including for the 6-unit parallel mode.
55.4 kg net and 67.7 kg gross. The unit itself measures 584 x 420 x 195 mm and its carton measures 670 x 470 x 355 mm, so plan the wall or floor space from the first figure and the doorway from the second. It is a low-frequency transformer-based design, IP21, air cooled, rated 0-40 °C in use and -15 to 60 °C in storage.