Défaut

05

High PV voltage.

6 Appareils signalant ce code
05High PV voltage.Défaut
Description

High PV voltage.

Correction recommandée

Please check the voltage of the solar panel, it should be less than 95V. if the voltage is ok, please contact your installer.

Source:ICM.pdf · page 13
05PV over current fault.Défaut
Description

PV input over current fault.

Correction recommandée

1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.

Source:Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 53
05High Charging Current.Avertissement
Description

Charging current above safe limit.

Cause

Excessive charging current from inverter/charger.

Correction recommandée

Reduce charging current.

Source:LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 21
05High Charging Current.Avertissement
Description

Charging current exceeded the upper threshold.

Correction recommandée

Reduce charging current.

Source:LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf · page 20
05High Charging Current.Défaut
Description

High Charging Current.

Source:LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf · page 27
05PV is high loss.Critique
Description

Solar (PV) input voltage exceeds the controller's maximum allowable input voltage (140V or 190V depending on model).

Cause

PV array open-circuit voltage exceeds the controller's maximum solar input voltage rating (95V for 30A/45A models with 12V/24V; 145V for 45A/60A/80A 48V models; 165V for 100A/120A models).

Correction recommandée

1. Please check the voltage of the solar panel, it should be less than 140V or 190V. 2. if the voltage is ok, please contact your installer.

Source:felicitysolar SCCM-III MPPT Solar Charge Controller User Guide.pdf · page 18

Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.