05
High PV voltage.
05High PV voltage.Défaut
High PV voltage.
Please check the voltage of the solar panel, it should be less than 95V. if the voltage is ok, please contact your installer.
ICM.pdf · page 1305PV over current fault.Défaut
PV input over current fault.
1. Restart the system 2~3 times; 2. if the fault still exists, please contact us for help.
Felicitysolar IVGM Series Hybrid inverter Instruction Manual.pdf · page 5305High Charging Current.Avertissement
Charging current above safe limit.
Excessive charging current from inverter/charger.
Reduce charging current.
LUX-X-96050HG01-Lithium-Battery-User-Guide.pdf · page 2105High Charging Current.Avertissement
Charging current exceeded the upper threshold.
Reduce charging current.
LUX-Y-48100HG01-Lithium-Battery-User-Guide.pdf · page 2005High Charging Current.Défaut
High Charging Current.
LUX-Y-48100HG01MN User manual 358-S010025-03 0325(V2.0).pdf · page 2705PV is high loss.Critique
Solar (PV) input voltage exceeds the controller's maximum allowable input voltage (140V or 190V depending on model).
PV array open-circuit voltage exceeds the controller's maximum solar input voltage rating (95V for 30A/45A models with 12V/24V; 145V for 45A/60A/80A 48V models; 165V for 100A/120A models).
1. Please check the voltage of the solar panel, it should be less than 140V or 190V. 2. if the voltage is ok, please contact your installer.
felicitysolar SCCM-III MPPT Solar Charge Controller User Guide.pdf · page 18Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.