This is the complete fault table for the Felicity IVCM1012 PRO Inverter family — 26 codes shared by 3 model numbers, transcribed from the official manual. On Felicity units, a fault code means the unit has cut its output and the red LED stays solid; a warning flashes the red LED while the unit keeps running.

Also coversIVCM2024 PROIVCM3024 PRO

Last checked against the official manuals on July 10, 2026.

How to read the severity labels

  • Fault(26)output stops · red LED solid

Fault codes (26)output stops · red LED solid

03Fault

PV charging overcurrent.

Fault

CauseThe charging current from the PV input exceeded the charger stage's protection limit: the array is delivering more current than the charging circuit is rated to handle.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 13

04Fault

PV temperature is too high.

Fault

CauseThe PV charger stage has overheated above its protection limit, typically because the unit's airflow is blocked or the ambient temperature is too high.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ICM.pdf· page 13

05Fault

High PV voltage.

Fault

CauseThe solar array voltage at the PV input is above the unit's maximum allowed input voltage, usually because too many panels are wired in series for this input.

Recommended fixPlease check the voltage of the solar panel, it should be less than 95V. if the voltage is ok, please contact your installer.

Source:ICM.pdf· page 13

06Fault

PV relay voltage abnormal.

Fault

The PV relay voltage is abnormal.

CauseA safety relay inside the inverter has failed self-test or is stuck. The inverter is designed to refuse grid connection in this state, so this is not an issue you can clear with restart cycles.

Recommended fixInternal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 13

07Fault

Battery voltage too high.

Fault

Battery voltage is too high.

CauseThe measured battery voltage is above the allowed maximum for the configured system voltage: either an external source is overcharging the battery, or an internal measurement or charging component has failed.

Recommended fixInternal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 13ICM.pdf· page 13

08Fault

Fan 1 locked.

Fault

Fan 1 is locked.

CauseInternal cooling fan failure detected. Often caused by dust buildup, bearing wear, or debris fouling the fan blades.

Recommended fixCheck if the Fans wiring connected well. Replace the fan.

Source:ICM.pdf· page 13

09Fault

Fan 2 locked.

Fault

Fan 2 is locked.

CauseInternal cooling fan failure detected. Often caused by dust buildup, bearing wear, or debris fouling the fan blades.

Recommended fixCheck if the Fans wiring connected well. Replace the fan.

Source:ICM.pdf· page 13

10Fault

Overload.

Fault

CauseThe connected load is drawing more power than the inverter's rated output capacity.

Recommended fixPower down the inverter, wait 5 minutes for capacitors to discharge, then restart. If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.

Source:ICM.pdf· page 13

11Fault

Low battery.

Fault

CauseThe battery voltage has dropped below the low-battery threshold: the battery is discharged and needs charging.

Recommended fixThe battery voltage is too low, it should be charging.

Source:ICM.pdf· page 13

16Fault

Primary-secondary CPU communication fault.

Fault

The communication between the primary and secondary cpus is faulty.

CauseCommunication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.

Recommended fixInternal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 13

17Fault

Overload protection.

Fault

CauseThe output was overloaded long enough to trip overload protection: the connected loads exceed what the inverter can supply continuously.

Recommended fixReduce the loads and Restart the machine.

Source:ICM.pdf· page 13

19Fault

Output short circuit.

Fault

CauseA short circuit was detected on the AC output: a wiring fault or a failed appliance pulling far more current than any normal load.

Recommended fixCheck if wiring is connected well and remove abnormal load.

Source:ICM.pdf· page 13

21Fault

OP current sensor failed.

Fault

OP (output) current sensor failed.

CauseThe output current sensor has failed, so the inverter can no longer measure its output current reliably. This is an internal component fault.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 13

22Fault

Output voltage too low.

Fault

Output voltage is too low.

CauseThe AC output voltage sagged below the allowed range, most often because a heavy load is dragging the output down, otherwise an internal voltage-regulation fault.

Recommended fixReduce the connected load. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 14

23Fault

Output voltage too high.

Fault

Output voltage is too high.

CauseThe AC output voltage rose above the allowed range. This points to an internal voltage-regulation fault in the inverter stage.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 14

24Fault

Excessive inverter current.

Fault

CauseThe inverter stage current exceeded its software protection limit: the connected loads, or a startup surge from motor or compressor equipment, are drawing more current than the rating.

Recommended fixReduce the connected load by switching off some equipment.

Source:ICM.pdf· page 14

25Fault

Inverter hardware current too large.

Fault

The inverter hardware current is too large.

CauseThe hardware over-current protection on the inverter stage tripped: a sudden current spike beyond the hardware limit, typically a load surge or an output fault.

Recommended fixReduce the connected load by switching off some equipment.

Source:ICM.pdf· page 14

26Fault

Inverter voltage soft start fail.

Fault

The soft start of the inverter voltage fails.

CauseThe inverter output voltage failed to ramp up during its soft-start sequence. This is an internal component fault in the inverter stage.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 14

29Fault

Inverter current sensor faulty.

Fault

The inverter current sensor is faulty.

CauseThe inverter-stage current sensor is faulty and its readings can no longer be trusted. This is an internal component failure.

Recommended fixContact the repair center.

Source:ICM.pdf· page 14

30Fault

Bus voltage too low.

Fault

Bus voltage is too low.

CauseThe internal DC bus voltage fell below its minimum operating threshold: weak input power from the battery or PV side, or an internal bus-converter fault.

Recommended fixRestart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 14

31Fault

Bus voltage too high.

Fault

Bus voltage is too high.

CauseThe internal DC bus voltage exceeded its safe limit: an AC surge on the input, or failed internal components.

Recommended fixAC Surge or internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 14

33Fault

Bus soft start fail.

Fault

CauseThe DC bus failed to precharge during the soft-start sequence: failed internal components.

Recommended fixInternal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf· page 14

34Fault

Radiator 1 over-temperature.

Fault

Overtemperature occurs in radiator 1.

CauseInverter internal temperature has exceeded the safe operating threshold. Causes include high ambient temperature, blocked cooling vents, failed cooling fan, or installation in direct sunlight.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ICM.pdf· page 14

35Fault

Radiator 2 over-temperature.

Fault

Overtemperature occurs in radiator 2.

CauseInverter internal temperature has exceeded the safe operating threshold. Causes include high ambient temperature, blocked cooling vents, failed cooling fan, or installation in direct sunlight.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ICM.pdf· page 14

50Fault

EEPROM fault.

Fault

CauseThe EEPROM that stores the unit's settings and calibration data failed a read/write check. This is an internal memory fault.

Recommended fixContact the repair center.

Source:ICM.pdf· page 14

90Fault

DSP BootLoad not written.

Fault

DSP BootLoad is not written.

CauseThe DSP's bootloader firmware is missing or was never programmed, so the main processor cannot start. This is a factory or firmware fault that requires service.

Recommended fixContact the repair center.

Source:ICM.pdf· page 14

Still seeing a code on your IVCM1012 PRO?

Send us the code on your screen and a Felicity technician will reply with the exact steps for your unit. Support is free for life — a first diagnosis never needs a callout.

Keep troubleshooting

Related devices

Common questions about IVCM1012 PRO error codes

What is the difference between a fault and a warning on the IVCM1012 PRO?
A fault cuts the unit's output and the red LED stays solid — this page lists 26 of them for the IVCM1012 PRO. The IVCM1012 PRO manual defines no separate warning table — every listed code stops operation. Resolve the cause of a fault before restarting; warnings can usually be cleared while the unit runs.
Which model numbers does this page cover?
The IVCM1012 PRO shares its firmware and fault table with 2 other model numbers: IVCM2024 PRO, IVCM3024 PRO. If your unit is any of these, every code on this page applies to it.
Where do these codes come from?
Every entry was transcribed from ICM.pdf — Felicity's official documentation. Each row cites its source manual (and page where printed), so you can verify the wording before acting on it.

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.