IVCM1012 PRO

Inverter26 codes
also coversIVCM2024 PROIVCM3024 PRO
26 Fault
03PV charging overcurrent.Fault
Description

PV charging overcurrent.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 13
04PV temperature is too high.Fault
Description

PV temperature is too high.

Recommended fix

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ICM.pdf · page 13
05High PV voltage.Fault
Description

High PV voltage.

Recommended fix

Please check the voltage of the solar panel, it should be less than 95V. if the voltage is ok, please contact your installer.

Source:ICM.pdf · page 13
06PV relay voltage abnormal.Fault
Description

The PV relay voltage is abnormal.

Recommended fix

Internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 13
07Battery voltage too high.Fault
Description

Battery voltage is too high.

Recommended fix

Internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 13ICM.pdf · page 13
08Fan 1 locked.Fault
Description

Fan 1 is locked.

Recommended fix

Check if the Fans wiring connected well. Replace the fan.

Source:ICM.pdf · page 13
09Fan 2 locked.Fault
Description

Fan 2 is locked.

Recommended fix

Check if the Fans wiring connected well. Replace the fan.

Source:ICM.pdf · page 13
10Overload.Fault
Description

Overload.

Recommended fix

Reduce the loads.

Source:ICM.pdf · page 13
11Low battery.Fault
Description

Low battery.

Recommended fix

The battery voltage is too low, it should be charging.

Source:ICM.pdf · page 13
16Primary-secondary CPU communication fault.Fault
Description

The communication between the primary and secondary cpus is faulty.

Recommended fix

Internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 13
17Overload protection.Fault
Description

Overload protection.

Recommended fix

Reduce the loads and Restart the machine.

Source:ICM.pdf · page 13
19Output short circuit.Fault
Description

Output short circuit.

Recommended fix

Check if wiring is connected well and remove abnormal load.

Source:ICM.pdf · page 13
21OP current sensor failed.Fault
Description

OP (output) current sensor failed.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 13
22Output voltage too low.Fault
Description

Output voltage is too low.

Recommended fix

Reduce the connected load. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
23Output voltage too high.Fault
Description

Output voltage is too high.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
24Excessive inverter current.Fault
Description

Excessive inverter current.

Recommended fix

Reduce the connected load by switching off some equipment.

Source:ICM.pdf · page 14
25Inverter hardware current too large.Fault
Description

The inverter hardware current is too large.

Recommended fix

Reduce the connected load by switching off some equipment.

Source:ICM.pdf · page 14
26Inverter voltage soft start fail.Fault
Description

The soft start of the inverter voltage fails.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
29Inverter current sensor faulty.Fault
Description

The inverter current sensor is faulty.

Recommended fix

Contact the repair center.

Source:ICM.pdf · page 14
30Bus voltage too low.Fault
Description

Bus voltage is too low.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
31Bus voltage too high.Fault
Description

Bus voltage is too high.

Recommended fix

AC Surge or internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
33Bus soft start fail.Fault
Description

Bus soft start fail.

Recommended fix

Internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
34Radiator 1 over-temperature.Fault
Description

Overtemperature occurs in radiator 1.

Recommended fix

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ICM.pdf · page 14
35Radiator 2 over-temperature.Fault
Description

Overtemperature occurs in radiator 2.

Recommended fix

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ICM.pdf · page 14
50EEPROM fault.Fault
Description

EEPROM fault.

Recommended fix

Contact the repair center.

Source:ICM.pdf · page 14
90DSP BootLoad not written.Fault
Description

DSP BootLoad is not written.

Recommended fix

Contact the repair center.

Source:ICM.pdf · page 14

Compiled from official FelicityESS user manuals. Always consult your device manual and a qualified technician before performing repairs.