IVCM1012 PRO

Onduleur26 codes
also coversIVCM2024 PROIVCM3024 PRO
26 Défaut
03PV charging overcurrent.Défaut
Description

PV charging overcurrent.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 13
04PV temperature is too high.Défaut
Description

PV temperature is too high.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ICM.pdf · page 13
05High PV voltage.Défaut
Description

High PV voltage.

Correction recommandée

Please check the voltage of the solar panel, it should be less than 95V. if the voltage is ok, please contact your installer.

Source:ICM.pdf · page 13
06PV relay voltage abnormal.Défaut
Description

The PV relay voltage is abnormal.

Correction recommandée

Internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 13
07Battery voltage too high.Défaut
Description

Battery voltage is too high.

Correction recommandée

Internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 13ICM.pdf · page 13
08Fan 1 locked.Défaut
Description

Fan 1 is locked.

Correction recommandée

Check if the Fans wiring connected well. Replace the fan.

Source:ICM.pdf · page 13
09Fan 2 locked.Défaut
Description

Fan 2 is locked.

Correction recommandée

Check if the Fans wiring connected well. Replace the fan.

Source:ICM.pdf · page 13
10Overload.Défaut
Description

Overload.

Correction recommandée

Reduce the loads.

Source:ICM.pdf · page 13
11Low battery.Défaut
Description

Low battery.

Correction recommandée

The battery voltage is too low, it should be charging.

Source:ICM.pdf · page 13
16Primary-secondary CPU communication fault.Défaut
Description

The communication between the primary and secondary cpus is faulty.

Correction recommandée

Internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 13
17Overload protection.Défaut
Description

Overload protection.

Correction recommandée

Reduce the loads and Restart the machine.

Source:ICM.pdf · page 13
19Output short circuit.Défaut
Description

Output short circuit.

Correction recommandée

Check if wiring is connected well and remove abnormal load.

Source:ICM.pdf · page 13
21OP current sensor failed.Défaut
Description

OP (output) current sensor failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 13
22Output voltage too low.Défaut
Description

Output voltage is too low.

Correction recommandée

Reduce the connected load. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
23Output voltage too high.Défaut
Description

Output voltage is too high.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
24Excessive inverter current.Défaut
Description

Excessive inverter current.

Correction recommandée

Reduce the connected load by switching off some equipment.

Source:ICM.pdf · page 14
25Inverter hardware current too large.Défaut
Description

The inverter hardware current is too large.

Correction recommandée

Reduce the connected load by switching off some equipment.

Source:ICM.pdf · page 14
26Inverter voltage soft start fail.Défaut
Description

The soft start of the inverter voltage fails.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
29Inverter current sensor faulty.Défaut
Description

The inverter current sensor is faulty.

Correction recommandée

Contact the repair center.

Source:ICM.pdf · page 14
30Bus voltage too low.Défaut
Description

Bus voltage is too low.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
31Bus voltage too high.Défaut
Description

Bus voltage is too high.

Correction recommandée

AC Surge or internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
33Bus soft start fail.Défaut
Description

Bus soft start fail.

Correction recommandée

Internal components failed. Restart the unit, if the error persists, contact the repair center.

Source:ICM.pdf · page 14
34Radiator 1 over-temperature.Défaut
Description

Overtemperature occurs in radiator 1.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ICM.pdf · page 14
35Radiator 2 over-temperature.Défaut
Description

Overtemperature occurs in radiator 2.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ICM.pdf · page 14
50EEPROM fault.Défaut
Description

EEPROM fault.

Correction recommandée

Contact the repair center.

Source:ICM.pdf · page 14
90DSP BootLoad not written.Défaut
Description

DSP BootLoad is not written.

Correction recommandée

Contact the repair center.

Source:ICM.pdf · page 14

Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.