InvertersModel IVPS5048P1G1-LV
Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger
A single-phase off-grid inverter charger rated 4 kW / 5 kVA, running a 110-127 V pure sine output from a 48 V battery bank. We supply it as an authorised Felicity Solar distributor.
- Rated Output Power: 4 kW
- Max Efficiency: 90 %
- Battery Voltage Range: 42-63 V
- Phase: Single Phase
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: AED 180
- 2-year warranty
Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger features
110-127 V AC output, pure sine wave at 50/60 Hz, output voltage regulation held to 5%
Twice rated load for 5 seconds and motor-start capability from the low-frequency design
Three-stage charging up to 50 A: 57.6 V bulk, 54.4 V float, over a 42-63 V battery window
15 ms transfer time, AC input 80-140 V in appliance mode or 90-140 V in UPS mode, 63 A pass-through
Up to 9 units in parallel, RS485 BMS link, IP21 chassis at 31.35 kg net
About the Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger
The Felicity Solar IVPS5048P1G1-LV is a single-phase off-grid inverter charger that delivers 4 kW of rated output power, 5 kVA apparent, from a 48 V battery bank to a 110-127 V AC output, in pure sine wave, with a 15 ms transfer time between utility and battery. The LV designation shows in those AC figures: nominal input 110-120 V, output 110-127 V, wired L-N. The low-frequency, transformer-based design carries twice rated load for 5 seconds and is motor-start capable, so pumps and compressors start without tripping it. AC input accepts 80-140 V in appliance mode and 90-140 V in UPS mode at 50/60 Hz, passing through up to 63 A; with no battery connected there is no pass-through. Charging is three-stage - boost CC, boost CV, float - up to 50 A, at 57.6 V bulk and 54.4 V float, across a 42-63 V battery window covering AGM, flooded, lithium-ion and self-defined profiles. RS485 carries BMS data, up to 9 units run in parallel, and line-mode efficiency is above 95%. The IP21 chassis measures 494 x 420 x 195 mm and weighs 31.35 kg net. We are an authorised Felicity Solar distributor and supply the IVPS5048P1G1-LV from our own stock.
Specifications last updated 23 July 2026
Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger full specifications
Electrical(55)
| AC Output Voltage | 110-127 V |
|---|---|
| AC Wiring Mode | L-N |
| Backup Rated Output Power | 4 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 42-63 V |
| Bulk Charging Voltage | 57.6 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 54.4 V |
| High DC Input Recovery Voltage | 62 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 140 V |
| High Line Reconnect Voltage | 135 V |
| Input Voltage Range | 80-140 V |
| Input Voltage Range (UPS Mode) | 90-140 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | >95 % |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (<50% Load) | 43 V |
| Low DC Shutdown (>50% Load) | 42 V |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 80 V |
| Low Line Disconnect (UPS Mode) | 90 V |
| Low Line Reconnect (Appliance Mode) | 85 V |
| Low Line Reconnect (UPS Mode) | 95 V |
| Low-Battery Recovery (<50% Load) | 47 V |
| Low-Battery Recovery (>50% Load) | 46 V |
|---|---|
| Max AC Charge Current | 50 A |
| Max AC Input Voltage | 140 V |
| Max AC Pass-Through Current | 63 A |
| Max Charging Current | 50 A |
| Max Charging Voltage | 61.0 V |
| Max Efficiency | 90 % |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 110-120 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Air Switch Protection |
| Overload Trip Time (>105% Load) | 10 s |
| Overload Trip Time (>150% Load) | 5 s |
| Pass-Through Without Battery | No |
| Phase | Single Phase |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| Rated Apparent Output Power | 5 kVA |
| Rated Output Power | 4 kW |
| Short-Circuit Protection (Line Mode) | Air Switch Protection |
| Start-Up Voltage | 46 V |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 15 ms |
Mechanical(8)
| BMS Communication | RS485 |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD, LED |
| Gross Weight | 35.05 kg |
| Net Weight | 31.35 kg |
| Package Dimensions | 607 x 540 x 290 mm |
| Parallel Capability | 9 |
| Topology | Low-Frequency (transformer-based) |
Environmental(4)
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | 0-40 °C |
| Storage Temperature | -15 to 60 °C |
Downloads & support
Troubleshooting & error codes
Looking up an error code on this FelicityESS IVPS3524P1G1-LV? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →Frequently Asked Questions
What is the rated output power of the IVPS5048P1G1-LV?
It is rated at 4 kW of output power, 5 kVA apparent, on a single phase, and its backup rated output power is also 4 kW. The low-frequency, transformer-based design carries twice rated load for 5 seconds, and the unit is motor-start capable.
What battery does the IVPS5048P1G1-LV run on, and how fast does it charge?
Nominal DC input is 48 V, with a working battery range of 42-63 V and start-up at 46 V. Charging is three-stage - boost CC, boost CV, float - at up to 50 A, with 57.6 V bulk and 54.4 V float and a 61.0 V maximum. AGM, flooded, lithium-ion and self-defined profiles are selectable, and BMS data runs over RS485.
What AC input and output does it handle?
AC output is 110-127 V single phase, L-N, at 50/60 Hz, pure sine wave, with output voltage regulation of 5%. Nominal AC input is 110-120 V; the unit accepts 80-140 V in appliance mode or 90-140 V in UPS mode, transfers in 15 ms and passes through up to 63 A. There is no pass-through without a battery connected.
Can units be paralleled, and what are the physical specifications?
Up to 9 units can run in parallel. Each unit measures 494 x 420 x 195 mm and weighs 31.35 kg net, 35.05 kg gross, in a 607 x 540 x 290 mm carton. The chassis is IP21 with intelligent air cooling, an LCD and LED display, and an operating temperature range of 0-40 C.