Felicity Solar IVPS5048P1G1-LV

InvertersModel IVPS5048P1G1-LV

Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger

A single-phase off-grid inverter charger rated 4 kW / 5 kVA, running a 110-127 V pure sine output from a 48 V battery bank. We supply it as an authorised Felicity Solar distributor.

  • Rated Output Power: 4 kW
  • Max Efficiency: 90 %
  • Battery Voltage Range: 42-63 V
  • Phase: Single Phase
AED 1,750incl. VAT

In stock

  • Delivered within 3 business days, door to door, to every market we serve.
  • Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
  • Delivery charge: AED 180
  • 2-year warranty

Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger features

  • 4 kW rated output power and 5 kVA apparent power, single phase, from a 48 V battery bank

  • 110-127 V AC output, pure sine wave at 50/60 Hz, output voltage regulation held to 5%

  • Twice rated load for 5 seconds and motor-start capability from the low-frequency design

  • Three-stage charging up to 50 A: 57.6 V bulk, 54.4 V float, over a 42-63 V battery window

  • 15 ms transfer time, AC input 80-140 V in appliance mode or 90-140 V in UPS mode, 63 A pass-through

  • Up to 9 units in parallel, RS485 BMS link, IP21 chassis at 31.35 kg net

About the Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger

The Felicity Solar IVPS5048P1G1-LV is a single-phase off-grid inverter charger that delivers 4 kW of rated output power, 5 kVA apparent, from a 48 V battery bank to a 110-127 V AC output, in pure sine wave, with a 15 ms transfer time between utility and battery. The LV designation shows in those AC figures: nominal input 110-120 V, output 110-127 V, wired L-N. The low-frequency, transformer-based design carries twice rated load for 5 seconds and is motor-start capable, so pumps and compressors start without tripping it. AC input accepts 80-140 V in appliance mode and 90-140 V in UPS mode at 50/60 Hz, passing through up to 63 A; with no battery connected there is no pass-through. Charging is three-stage - boost CC, boost CV, float - up to 50 A, at 57.6 V bulk and 54.4 V float, across a 42-63 V battery window covering AGM, flooded, lithium-ion and self-defined profiles. RS485 carries BMS data, up to 9 units run in parallel, and line-mode efficiency is above 95%. The IP21 chassis measures 494 x 420 x 195 mm and weighs 31.35 kg net. We are an authorised Felicity Solar distributor and supply the IVPS5048P1G1-LV from our own stock.

Specifications last updated 23 July 2026

Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger full specifications

Electrical(55)

AC Output Voltage110-127 V
AC Wiring ModeL-N
Backup Rated Output Power4 kW
Battery Inputs1
Battery TypeAGM, Flooded, Li-Ion, Self-Defined
Battery Voltage Range42-63 V
Bulk Charging Voltage57.6 V
Charge AlgorithmThree-Stage: Boost CC, Boost CV, Float
Float Charging Voltage54.4 V
High DC Input Recovery Voltage62 V
High Frequency Disconnect65 Hz
High Frequency Reconnect63 Hz
High Line Disconnect Voltage140 V
High Line Reconnect Voltage135 V
Input Voltage Range80-140 V
Input Voltage Range (UPS Mode)90-140 V
Input Voltage WaveformSinusoidal (utility or generator)
Line Mode Efficiency>95 %
Line Mode Output WaveformSame As Input Waveform
Low DC Shutdown (<50% Load)43 V
Low DC Shutdown (>50% Load)42 V
Low Frequency Disconnect40 Hz
Low Frequency Reconnect42 Hz
Low Line Disconnect (Appliance Mode)80 V
Low Line Disconnect (UPS Mode)90 V
Low Line Reconnect (Appliance Mode)85 V
Low Line Reconnect (UPS Mode)95 V
Low-Battery Recovery (<50% Load)47 V
Low-Battery Recovery (>50% Load)46 V
Max AC Charge Current50 A
Max AC Input Voltage140 V
Max AC Pass-Through Current63 A
Max Charging Current50 A
Max Charging Voltage61.0 V
Max Efficiency90 %
Motor Start CapableYes
Nominal AC Input Voltage110-120 V
Nominal DC Input Voltage48 V
Nominal Input Frequency50/60 Hz
Output Frequency50/60 Hz
Output Short-Circuit ProtectionYes
Output Voltage Regulation5 %
Output Voltage WaveformPure Sine Wave
Overload ProtectionAir Switch Protection
Overload Trip Time (>105% Load)10 s
Overload Trip Time (>150% Load)5 s
Pass-Through Without BatteryNo
PhaseSingle Phase
ProtectionOver Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection
Rated Apparent Output Power5 kVA
Rated Output Power4 kW
Short-Circuit Protection (Line Mode)Air Switch Protection
Start-Up Voltage46 V
Surge Rating2*rated (5s)
Transfer Time15 ms

Mechanical(8)

BMS CommunicationRS485
Communication InterfaceRS232, RS485
DisplayLCD, LED
Gross Weight35.05 kg
Net Weight31.35 kg
Package Dimensions607 x 540 x 290 mm
Parallel Capability9
TopologyLow-Frequency (transformer-based)

Environmental(4)

CoolingIntelligent Air Cooling
IP RatingIP21
Operating Temperature Range0-40 °C
Storage Temperature-15 to 60 °C

Downloads & support

PDFThe manufacturer's sheet, to print or share

Troubleshooting & error codes

Looking up an error code on this FelicityESS IVPS3524P1G1-LV? Browse the full list of codes for this device, with the cause and recommended fix for each.

View error codes for this device →

Frequently Asked Questions

What is the rated output power of the IVPS5048P1G1-LV?

It is rated at 4 kW of output power, 5 kVA apparent, on a single phase, and its backup rated output power is also 4 kW. The low-frequency, transformer-based design carries twice rated load for 5 seconds, and the unit is motor-start capable.

What battery does the IVPS5048P1G1-LV run on, and how fast does it charge?

Nominal DC input is 48 V, with a working battery range of 42-63 V and start-up at 46 V. Charging is three-stage - boost CC, boost CV, float - at up to 50 A, with 57.6 V bulk and 54.4 V float and a 61.0 V maximum. AGM, flooded, lithium-ion and self-defined profiles are selectable, and BMS data runs over RS485.

What AC input and output does it handle?

AC output is 110-127 V single phase, L-N, at 50/60 Hz, pure sine wave, with output voltage regulation of 5%. Nominal AC input is 110-120 V; the unit accepts 80-140 V in appliance mode or 90-140 V in UPS mode, transfers in 15 ms and passes through up to 63 A. There is no pass-through without a battery connected.

Can units be paralleled, and what are the physical specifications?

Up to 9 units can run in parallel. Each unit measures 494 x 420 x 195 mm and weighs 31.35 kg net, 35.05 kg gross, in a 607 x 540 x 290 mm carton. The chassis is IP21 with intelligent air cooling, an LCD and LED display, and an operating temperature range of 0-40 C.