- Rated Output Power: 6 kW
- Max Efficiency: 90 %
- Battery Voltage Range: 42-63 V
- Phase: Single Phase
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: AED 165
- 2-year warranty
Felicity Solar IVPS7548 6kW Single-Phase Inverter / Charger features
48 V battery bank with a 42-63 V operating window and charging up to 60 A
Low-frequency design carries 2x rated power for 5 seconds to start motor loads
Two AC input windows: 170-280 V UPS mode or 90-280 V appliance mode, 15 ms transfer
Three-stage charging at 57.6 V bulk and 54.4 V float for AGM, flooded, Li-Ion and self-defined banks
Up to 6 units in parallel, 90% peak efficiency and over 95% in line mode
About the Felicity Solar IVPS7548 6kW Single-Phase Inverter / Charger
The Felicity Solar IVPS7548 is a 6 kW single-phase off-grid inverter-charger for a 48 V battery bank. It is rated 7.5 kVA of apparent power, delivers a pure sine wave at 220 V and 50/60 Hz, and charges at up to 60 A from utility or generator supply. Its low-frequency topology carries twice rated power for 5 seconds, so motor loads such as pumps and compressors start without tripping out. Two AC input windows decide how it behaves: UPS mode holds 170-280 V for sensitive electronics, while appliance mode widens to 90-280 V on weak grids, with a 15 ms transfer time either way. Charging runs a three-stage boost CC, boost CV and float profile at 57.6 V bulk and 54.4 V float, covering AGM, flooded, lithium-ion and self-defined banks, with RS485 for BMS data and RS232 for monitoring. Peak efficiency is 90%, above 95% in line mode, and up to six units run in parallel. The unit measures 494 x 420 x 195 mm, weighs 29.1 kg and is rated IP21 for indoor mounting. We are an authorised Felicity Solar distributor and supply the IVPS7548 from our own stock, with technical support before and after the sale.
Specifications last updated 23 March 2026
Felicity Solar IVPS7548 6kW Single-Phase Inverter / Charger full specifications
Electrical(55)
| AC Output Voltage | 220 V |
|---|---|
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 6 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 42-63 V |
| Bulk Charging Voltage | 57.6 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 54.4 V |
| High DC Input Recovery Voltage | 62 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 280 V |
| High Line Reconnect Voltage | 270 V |
| Input Voltage Range | 90-280 V |
| Input Voltage Range (UPS Mode) | 170-280 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | >95 % |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (<50% Load) | 43 V |
| Low DC Shutdown (>50% Load) | 42 V |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 90 V |
| Low Line Disconnect (UPS Mode) | 170 V |
| Low Line Reconnect (Appliance Mode) | 100 V |
| Low Line Reconnect (UPS Mode) | 180 V |
| Low-Battery Recovery (<50% Load) | 47 V |
| Low-Battery Recovery (>50% Load) | 46 V |
|---|---|
| Max AC Charge Current | 60 A |
| Max AC Input Voltage | 280 V |
| Max AC Pass-Through Current | 63 A |
| Max Charging Current | 60 A |
| Max Charging Voltage | 61.0 V |
| Max Efficiency | 90 % |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 220 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Air Switch Protection |
| Overload Trip Time (>105% Load) | 10 s |
| Overload Trip Time (>150% Load) | 5 s |
| Pass-Through Without Battery | No |
| Phase | Single Phase |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| Rated Apparent Output Power | 7.5 kVA |
| Rated Output Power | 6 kW |
| Short-Circuit Protection (Line Mode) | Air Switch Protection |
| Start-Up Voltage | 46 V |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 15 ms |
Mechanical(8)
| BMS Communication | RS485 |
|---|---|
| Communication Interface | RS232 |
| Display | LCD, LED |
| Gross Weight | 32.5 kg |
| Net Weight | 29.1 kg |
| Package Dimensions | 607 x 540 x 290 mm |
| Parallel Capability | 6 |
| Topology | Low-Frequency (transformer-based) |
Environmental(4)
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | 0-40 °C |
| Storage Temperature | -15 to 60 °C |
Downloads & support
Troubleshooting & error codes
Looking up an error code on this FelicityESS IVPS/IVPM Series? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →Frequently Asked Questions
What is the rated output power of the Felicity Solar IVPS7548?
It is rated 6 kW of real power and 7.5 kVA apparent, single phase at 220 V and 50/60 Hz, with a pure sine wave output. The low-frequency design carries twice rated power for 5 seconds, so motor loads such as pumps and compressors start without tripping the inverter.
Which battery bank does the IVPS7548 need?
A 48 V bank. It operates from 42 V to 63 V, starts up at 46 V, and charges at up to 60 A through a three-stage boost CC, boost CV and float profile at 57.6 V bulk, 54.4 V float and 61.0 V maximum. AGM, flooded, lithium-ion and self-defined types are supported, with RS485 for BMS communication.
How does the IVPS7548 handle a weak grid or a generator?
You choose the input window. UPS mode accepts 170-280 V for sensitive electronics and appliance mode accepts 90-280 V on unstable supply, and transfer takes 15 ms in either case. It disconnects below 40 Hz or above 65 Hz, and it will not pass utility power through unless a battery is connected.
What are the dimensions, weight and installation conditions?
The unit measures 494 x 420 x 195 mm and weighs 29.1 kg net, 32.5 kg gross, packed at 607 x 540 x 290 mm. It is rated IP21, so it mounts indoors in a protected location, and it runs from 0 to 40 °C with intelligent air cooling, an LCD and LED indicators.