7500VA / 6000W continuous output
Rated 7500VA and 6000W continuous, with a 15000VA surge sustained for 5 seconds.

InvertersModel IVPS7548P2G1
A 48V inverter-charger delivering 7500VA / 6000W continuously, with a 60A charger, a 15ms typical transfer time and 110/120Vac split-phase output taken from HOT1-N or HOT2-N.
What sets the IVPS7548P2G1 apart from the other model in the family: Output For supporting three-phase system, make sure no; Rated Output Power (VA) 7500VA; Rated Output Power (W) 6000W; Max Charge Current 60A; Charge Current Regulation 0-60A; Surge Rating 15000VA for 5 seconds; Product Dimension 494x420x195mm; Package Dimension 607x540x290mm.
In stock
Rated 7500VA and 6000W continuous, with a 15000VA surge sustained for 5 seconds.
Charges a 48V bank at up to 60A, regulated anywhere across the 0-60A range.
Delivers 110/120Vac ±5% between HOT1-N or HOT2-N, with HOT1-HOT2 as the terminal connection.
Accepts a 220Vac nominal input from 90-280Vac and transfers in 15ms typical.
Boost and float are 57.6V/54.4V for AGM and 58.4V/55.2V for flooded, with lithium capped at 61.0V.
A 38.2 kg chassis of 494 x 420 x 195 mm, rated for 0°C~40°C operation.
The Felicity Solar IVPS7548P2G1 is a 48V inverter-charger rated 7500VA / 6000W continuous, with a 15000VA surge held for 5 seconds, a 60A maximum charge current and a 15ms typical transfer time. The unit measures 494 x 420 x 195 mm and weighs 38.2 kg gross. It takes a 220Vac nominal input and charges from utility anywhere in a 90-280Vac window at 50Hz/60Hz, holding its own pure sine wave output to ±5%rms and synchronising with the incoming supply in line mode. Split-phase wiring gives 110/120Vac ±5% between HOT1-N or HOT2-N, while the HOT1-HOT2 terminal pair carries the full load. A 63A overcurrent protector guards the grid side, and air-switch overload protection tolerates 105%~150% load for 10 seconds and ≥150% for 5 seconds. Charging voltages are preset for AGM at 57.6V boost and 54.4V float, flooded cells at 58.4V and 55.2V, and lithium banks up to 61.0V; the inverter starts from 46V and shuts down at 43Vdc under light load. Operating range is 0°C~40°C. We are an authorised Felicity Solar distributor and supply the IVPS7548P2G1 from our own stock. Warranty: 2 Years.
Specifications last updated 23 July 2026
| Battery | 0₁ |
|---|---|
| Power | 0₁ |
| BMS communication | 24V model(default 27.0V) bm5 6 bmS |
| Capable of Starting Electric | Yes |
| Efficiency(Line mode) | >95% |
| Max. Bypass Overload Current | 30A AC63A |
| Nominal Output Frequency(Hz) | 50±0.3Hz/60±0.3Hz(adjustable) backlight will go out after 60s. |
| Output | For supporting three-phase system, make sure no |
| Output Frequency | 50Hz |
| Power derating | 216-06 221 |
| Rated Output Power (VA) | 7500VA |
| Rated Output Power (W) | 6000W |
| Nominal DC Input Voltage | 48V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Terminal Connection | HOT1-HOT2 |
| Nominal Input Voltage | 220Vac |
| Low Line Disconnect | 170±7Vac (UPS) / 90±7Vac (APL) |
| Low Line Re-connect AC Input Range | 180±7Vac (UPS) / 100±7Vac (APL) |
| High Line Disconnect | 280±7Vac |
| High Line Re-connect | 270±7Vac |
| Max AC Input Voltage | 280Vrms |
| Nominal Input Frequency | 50Hz/60Hz |
| Low Line Frequency Disconnect | 40±1Hz |
| Low Line Frequency Re-connect | 42±1Hz |
| High Line Frequency Disconnect | 65±1Hz |
| High Line Frequency Re-connect | 63±1Hz |
| Line Mode Output Waveform | Synchronize with input voltage |
| Over-Load Protection | Air switch protection |
| Efficiency (Line mode) | ≥95% |
| Transfer Time (AC to DC) | 15ms (typical) |
| Transfer Time (DC to AC) | 15ms (typical) / 30ms (special) |
|---|---|
| Pass Through Without Battery | No |
| Overcurrent Protector (grid) | 63A |
| Input Voltage Range (utility charge) | 90-280Vac |
| Max Charge Current | 60A |
| Charge Current Regulation | 0-60A |
| Charger Short Circuit | 63A |
| Over Charge Protection | Yes |
| Output Voltage Waveform | Pure sine wave |
| Nominal Output Voltage | 220/240Vac±5% (HOT1-HOT2) |
| Split-Phase Output Voltage | 110/120Vac±5% (HOT1-N or HOT2-N) |
| Nominal Output Frequency (Hz) | 50±0.3Hz / 60±0.3Hz (adjustable) |
| Output Voltage Regulation | ±5%rms |
| Peak Efficiency | 90% |
| Inverter Over-Load Protection (SMPS load) | 5s@≥150% load; 10s@105%~150% load |
| Surge Rating | 15000VA for 5 seconds |
| Capable of Starting Electric Motor | Yes |
| Output Short Circuit Protection | Yes |
| Min DC Starting Voltage | 46V |
| Low Battery Alarm | 46Vdc (load < 50%) / 44Vdc (load ≥ 50%) |
| Low Battery Recovery | 47Vdc (load < 50%) / 46Vdc (load ≥ 50%) |
| Low DC Input Shut-down | 43Vdc (load < 50%) / 42Vdc (load ≥ 50%) |
| High DC Input Alarm / Fault | 63Vdc±0.4V |
| High DC Input Recovery | 62Vdc±0.4V |
| Boost Charging Voltage (AGM) | 57.6V |
| Float Charging Voltage (AGM) | 54.4V |
| Boost Charging Voltage (Flooded) | 58.4V |
| Float Charging Voltage (Flooded) | 55.2V |
| Self-Defined Charging Voltage (max) | 61.0V |
| Lithium Charging Voltage (max) | 61.0V |
| Product Dimension | 494x420x195mm |
|---|---|
| Package Dimension | 607x540x290mm |
| Gross Weight | 38.2 kg |
| Operating temperature | 0°C~40°C |
|---|---|
| Storage temperature | -15°C~60°C |
Looking up an error code on this FelicityESS IVPS3524P1G1-LV? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →7500VA / 6000W continuous, with a 15000VA surge sustained for 5 seconds. The output is a pure sine wave regulated to ±5%rms at 50±0.3Hz / 60±0.3Hz (adjustable), and the unit is rated as capable of starting an electric motor.
60A is the maximum charge current, regulated across 0-60A. Boost and float voltages are 57.6V and 54.4V for AGM and 58.4V and 55.2V for flooded cells, while lithium charging is capped at 61.0V.
494 x 420 x 195 mm is the product dimension and the gross weight is 38.2 kg; the package measures 607 x 540 x 290 mm. Operating temperature is 0°C~40°C and storage is -15°C~60°C.
90-280Vac is the accepted utility charging range, and the input voltage waveform may be sinusoidal from utility or generator at 50Hz/60Hz. Transfer time is 15ms typical, and the unit does not pass through without a battery.