2.8 kW at 110-127 V
Rated output is 2.8 kW single phase, with the same 2.8 kW held on the backup output as a pure sine wave regulated within 5%.

InvertersModel IVPS3524P1G1-LV
A 2.8 kW single-phase inverter/charger built for 120 V supplies: 110-127 V output, an 80-140 V input window, 40 A three-stage charging on a 24 V bank, and up to eight units in parallel.
In stock
Rated output is 2.8 kW single phase, with the same 2.8 kW held on the backup output as a pure sine wave regulated within 5%.
Appliance mode accepts 80-140 V and only disconnects at 80 V, reconnecting at 85 V; UPS mode narrows the window to 90-140 V.
Charges a 24 V bank operating from 21 V to 31.5 V at up to 40 A, holding 28.8 V bulk and 27.2 V float across AGM, flooded, Li-Ion and self-defined types.
Transfer time is 15 ms and the unit carries twice rated load for 5 s, which is what starts a motor without stalling the output.
Up to 8 units run in parallel, with an RS485 BMS link, RS232 and RS485 interfaces and an LCD plus LED display.
Net weight is 27.7 kg and gross 30.8 kg in a 552 x 508 x 290 mm carton; the IP21 chassis is air cooled for 0-40 °C operation.
The Felicity Solar IVPS3524P1G1-LV is a single-phase inverter/charger rated 2.8 kW, holding the same 2.8 kW on its backup output. It runs a 24 V battery bank between 21 V and 31.5 V, puts out 110-127 V at 50/60 Hz on an L-N connection, accepts 80-140 V from utility or generator, and transfers in 15 ms. The -LV suffix is written into those AC figures: nominal input is 110-120 V, the appliance-mode window runs 80-140 V, and the unit holds on down to 80 V before disconnecting, reconnecting at 85 V, so a soft 120 V supply keeps feeding loads. UPS mode tightens the window to 90-140 V. Charging is three-stage - boost CC, boost CV, float - at up to 40 A, 28.8 V bulk and 27.2 V float, across AGM, flooded, Li-Ion and self-defined banks, with a BMS link over RS485. The low-frequency transformer build weighs 27.7 kg net, starts motors, carries twice rated load for 5 s, and parallels to eight units. An overcurrent protector handles overload, alongside over-charge, over-discharge, output short-circuit and over-temperature protection. Warranty: 2 Years. We are an authorised Felicity Solar distributor and supply the IVPS3524P1G1-LV from our own stock.
Specifications last updated 23 July 2026
| AC Output Voltage | 110-127 V |
|---|---|
| AC Wiring Mode | L-N |
| Backup Rated Output Power | 2.8 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 21-31.5 V |
| Bulk Charging Voltage | 28.8 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 27.2 V |
| High DC Input Recovery Voltage | 31 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 140 V |
| High Line Reconnect Voltage | 135 V |
| Input Voltage Range | 80-140 V |
| Input Voltage Range (UPS Mode) | 90-140 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | >95 % |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (<50% Load) | 21.5 V |
| Low DC Shutdown (>50% Load) | 21 V |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 80 V |
| Low Line Disconnect (UPS Mode) | 90 V |
| Low Line Reconnect (Appliance Mode) | 85 V |
| Low Line Reconnect (UPS Mode) | 95 V |
| Low-Battery Recovery (<50% Load) | 23.5 V |
| Low-Battery Recovery (>50% Load) | 23 V |
|---|---|
| Max AC Charge Current | 40 A |
| Max AC Input Voltage | 140 V |
| Max AC Pass-Through Current | 50 A |
| Max Charging Current | 40 A |
| Max Charging Voltage | 31.5 V |
| Max Efficiency | 90 % |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 110-120 V |
| Nominal DC Input Voltage | 24 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Overcurrent Protector |
| Overload Trip Time (>105% Load) | 10 s |
| Overload Trip Time (>150% Load) | 5 s |
| Pass-Through Without Battery | No |
| Phase | Single Phase |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| Rated Apparent Output Power | 3.5 kVA |
| Rated Output Power | 2.8 kW |
| Short-Circuit Protection (Line Mode) | Overcurrent Protector |
| Start-Up Voltage | 23 V |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 15 ms |
| BMS Communication | RS485 |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD, LED |
| Gross Weight | 30.8 kg |
| Net Weight | 27.7 kg |
| Package Dimensions | 552 x 508 x 290 mm |
| Parallel Capability | 8 |
| Topology | Low-Frequency (transformer-based) |
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | 0-40 °C |
| Storage Temperature | -15 to 60 °C |
Looking up an error code on this FelicityESS IVPS3524P1G1-LV? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →2.8 kW, single phase, and the same 2.8 kW stays available on the backup output. The waveform is a pure sine wave at 110-127 V and 50/60 Hz, regulated within 5%, and the unit carries twice rated load for 5 s to start motors.
24 V. The bank works anywhere from 21 V to 31.5 V on the single battery input. AGM, flooded, Li-Ion and self-defined types are supported, charged in three stages - boost CC, boost CV, float - at up to 40 A with 28.8 V bulk and 27.2 V float. It starts at 23 V and talks to a BMS over RS485.
80-140 V is the appliance-mode input window, so it holds on until 80 V and reconnects at 85 V; UPS mode uses 90-140 V. Input may be a sinusoidal utility or generator waveform at 50/60 Hz, and switching to battery takes 15 ms.
27.7 kg net and 30.8 kg gross. The unit measures 440 x 391 x 195 mm and ships in a 552 x 508 x 290 mm carton. It is a low-frequency, transformer-based build rated IP21 with intelligent air cooling, for 0-40 °C operation and -15 to 60 °C storage.