Felicity Solar Off-Grid Inverters IVPS10048P2G1/IVPS3524P1G1-LV/IVPS5048P1G1-LV/IVPS7548P2G1
A 48V inverter/charger holding 8000W continuous from a 10000VA rating, with split-phase 110/120Vac±5% output on HOT1-N or HOT2-N and 90% peak efficiency.
Models and prices
- IVPS10048P2G1AED 1,750incl. VAT
- IVPS3524P1G1-LVAED 1,750incl. VAT
- IVPS5048P1G1-LVAED 1,750incl. VAT
- IVPS7548P2G1AED 1,750incl. VAT
Technical Specifications
| Parameter | IVPS10048P2G1 | IVPS3524P1G1-LV | IVPS5048P1G1-LV | IVPS7548P2G1 |
|---|---|---|---|---|
| Additional Specifications | ||||
| Battery | 0₁ | |||
| Power | 0₁ | |||
| BMS communication | 24V model(default 27.0V) bm5 6 bmS | RS485 | RS485 | 24V model(default 27.0V) bm5 6 bmS |
| Capable of Starting Electric | Yes | |||
| Max. Bypass Overload Current | 30A AC63A | |||
| Output | split-phase system, make sure no "PAL", 3P1, 3P2 | — | — | For supporting three-phase system, make sure no |
| Output Frequency | 50Hz | 50/60 Hz | 50/60 Hz | 50Hz |
| Output voltage | 25.0V to 31.5V. Increment of | |||
| Power derating | 216-06 221 | |||
| Terminal Connection | HOT1-HOT2 | |||
| Nominal Input Voltage | 220Vac | |||
| Low Line Re-connect AC Input Range | 180±7Vac (UPS) / 100±7Vac (APL) | |||
| High Line Re-connect | 270±7Vac | |||
| Max AC Input Voltage | 280Vrms | 140 V | 140 V | 280Vrms |
| Nominal Input Frequency | 50Hz/60Hz | 50/60 Hz | 50/60 Hz | 50Hz/60Hz |
| Low Line Frequency Disconnect | 40±1Hz | |||
| Low Line Frequency Re-connect | 42±1Hz | |||
| High Line Frequency Disconnect | 65±1Hz | |||
| High Line Frequency Re-connect | 63±1Hz | |||
| Line Mode Output Waveform | Synchronize with input voltage | Same As Input Waveform | Same As Input Waveform | Synchronize with input voltage |
| Pass Through Without Battery | No | |||
| Overcurrent Protector (grid) | 63A | |||
| Split-Phase Output Voltage | 110/120Vac±5% (HOT1-N or HOT2-N) | |||
| Inverter Over-Load Protection (SMPS load) | 5s@≥150% load; 10s@105%~150% load | |||
| Capable of Starting Electric Motor | Yes | |||
| Output Short Circuit Protection | Yes | |||
| Min DC Starting Voltage | 46V | |||
| Lithium Charging Voltage (max) | 61.0V | |||
| Product Dimension | 584x420x195mm | — | — | 494x420x195mm |
| Gross Weight | 67.7 kg | 30.8 kg | 35.05 kg | 38.2 kg |
| Electrical Data | ||||
| Efficiency (Line mode) | ≥95% | |||
| Nominal Output Frequency (Hz) | 50±0.3Hz / 60±0.3Hz (adjustable) | |||
| Over Charge Protection | Yes | |||
| Low Battery Alarm | 46Vdc (load < 50%) / 44Vdc (load ≥ 50%) | |||
| High DC Input Alarm / Fault | 63Vdc±0.4V | |||
| AC Output | ||||
| Rated Output Power (VA) | 10000VA | — | — | 7500VA |
| Rated Output Power (W) | 8000W | — | — | 6000W |
| Nominal Output Voltage | 220/240Vac±5% (HOT1-HOT2) | |||
| Output Voltage Regulation | ±5%rms | 5% | 5% | ±5%rms |
| Peak Efficiency | 90% | |||
| DC Input | ||||
| Nominal DC Input Voltage | 48V | 24 V | 48 V | 48V |
| Electrical Characteristics | ||||
| Input Voltage Waveform | Sinusoidal (utility or generator) | |||
| Low Line Disconnect | 170±7Vac (UPS) / 90±7Vac (APL) | |||
| High Line Disconnect | 280±7Vac | |||
| Over-Load Protection | Air switch protection | Overcurrent Protector | Air Switch Protection | Air switch protection |
| Transfer Time (AC to DC) | 15ms (typical) | |||
| Transfer Time (DC to AC) | 15ms (typical) / 30ms (special) | |||
| Input Voltage Range (utility charge) | 90-280Vac | |||
| Max Charge Current | 80A | — | — | 60A |
| Charge Current Regulation | 0-80A | — | — | 0-60A |
| Charger Short Circuit | 63A | |||
| Output Voltage Waveform | Pure sine wave | Pure Sine Wave | Pure Sine Wave | Pure sine wave |
| Surge Rating | 20000VA for 5 seconds | 2*rated (5s) | 2*rated (5s) | 15000VA for 5 seconds |
| Low Battery Recovery | 47Vdc (load < 50%) / 46Vdc (load ≥ 50%) | |||
| Low DC Input Shut-down | 43Vdc (load < 50%) / 42Vdc (load ≥ 50%) | |||
| High DC Input Recovery | 62Vdc±0.4V | |||
| Boost Charging Voltage (AGM) | 57.6V | |||
| Float Charging Voltage (AGM) | 54.4V | |||
| Boost Charging Voltage (Flooded) | 58.4V | |||
| Float Charging Voltage (Flooded) | 55.2V | |||
| Self-Defined Charging Voltage (max) | 61.0V | |||
| Mechanical Data | ||||
| Package Dimension | 670x470x355mm | — | — | 607x540x290mm |
| Operating Conditions | ||||
| Operating Temperature | 0°C~40°C | |||
| Storage Temperature | -15°C~60°C | -15 to 60 °C | -15 to 60 °C | -15°C~60°C |
| Performance & Electrical | ||||
| AC Output Voltage | 110-127 V | |||
| AC Wiring Mode | L-N | |||
| Backup Rated Output Power | — | 2.8 kW | 4 kW | — |
| Battery Inputs | 1 | |||
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined | |||
| Battery Voltage Range | — | 21-31.5 V | 42-63 V | — |
| Bulk Charging Voltage | — | 28.8 V | 57.6 V | — |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float | |||
| Float Charging Voltage | — | 27.2 V | 54.4 V | — |
| High DC Input Recovery Voltage | — | 31 V | 62 V | — |
| High Frequency Disconnect | 65 Hz | |||
| High Frequency Reconnect | 63 Hz | |||
| High Line Disconnect Voltage | 140 V | |||
| High Line Reconnect Voltage | 135 V | |||
| Input Voltage Range | 80-140 V | |||
| Input Voltage Range (Appliance Mode) | 80-140 V | |||
| Input Voltage Range (UPS Mode) | 90-140 V | |||
| Line Mode Efficiency | >95% | |||
| Low DC Shutdown (>50% Load) | — | 21 V | 42 V | — |
| Low Frequency Disconnect | 40 Hz | |||
| Low Frequency Reconnect | 42 Hz | |||
| Low Line Disconnect (Appliance Mode) | 80 V | |||
| Low Line Disconnect (UPS Mode) | 90 V | |||
| Low Line Reconnect (Appliance Mode) | 85 V | |||
| Low Line Reconnect (UPS Mode) | 95 V | |||
| Low-Battery Recovery (>50% Load) | — | 23 V | 46 V | — |
| Max AC Charge Current | — | 40 A | 50 A | — |
| Max AC Pass-Through Current | — | 50 A | 63 A | — |
| Max Charging Current | — | 40 A | 50 A | — |
| Max Charging Voltage | — | 31.5 V | 61.0 V | — |
| Max Efficiency | 90% | |||
| Motor Start Capable | Yes | |||
| Nominal AC Input Voltage | 110-120 V | |||
| Overload Trip Time (>105% Load) | 10 s | |||
| Overload Trip Time (>150% Load) | 5 s | |||
| Phase | Single Phase | |||
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection | |||
| Rated Apparent Output Power | — | 3.5 kVA | 5 kVA | — |
| Rated Output Power | — | 2.8 kW | 4 kW | — |
| Short-Circuit Protection (Line Mode) | — | Overcurrent Protector | Air Switch Protection | — |
| Start-Up Voltage | — | 23 V | 46 V | — |
| Transfer Time | 15 ms | |||
| Build & Interfaces | ||||
| Communication Interface | RS232, RS485 | |||
| Display | LCD, LED | |||
| Net Weight | — | 27.7 kg | 31.35 kg | — |
| Package Dimensions | — | 552 x 508 x 290 mm | 607 x 540 x 290 mm | — |
| Parallel Capability | — | 8 | 9 | — |
| Topology | Low-Frequency (transformer-based) | |||
| Operating Environment | ||||
| Cooling | Intelligent Air Cooling | |||
| IP Rating | IP21 | |||
| Operating Temperature Range | 0-40 °C | |||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 10000VA rated, 8000W continuous: Rated 10000VA and 8000W continuous from a 48V nominal DC input.
- 20000VA surge for 5 seconds: Carries a 20000VA surge for 5 seconds and is rated to start electric motors.
- 80A maximum charge current: Charges at up to 80A, regulated anywhere across 0-80A, with over-charge protection.
- Split-phase 110/120Vac±5% output: Delivers split-phase 110/120Vac±5% on HOT1-N or HOT2-N from a 220Vac nominal input.
- 15ms (typical) transfer time: Transfers in 15ms (typical) and charges from utility anywhere in the 90-280Vac range.
- 584 x 420 x 195 mm, 67.7 kg gross: Measures 584 x 420 x 195 mm at 67.7 kg gross and operates from 0°C~40°C.
- 2.8 kW at 110-127 V: Rated output is 2.8 kW single phase, with the same 2.8 kW held on the backup output as a pure sine wave regulated within 5%.
- 80-140 V input window: Appliance mode accepts 80-140 V and only disconnects at 80 V, reconnecting at 85 V; UPS mode narrows the window to 90-140 V.
- 40 A three-stage charging: Charges a 24 V bank operating from 21 V to 31.5 V at up to 40 A, holding 28.8 V bulk and 27.2 V float across AGM, flooded, Li-Ion and self-defined types.
- 15 ms transfer, 2x surge: Transfer time is 15 ms and the unit carries twice rated load for 5 s, which is what starts a motor without stalling the output.
- Eight units in parallel: Up to 8 units run in parallel, with an RS485 BMS link, RS232 and RS485 interfaces and an LCD plus LED display.
- 27.7 kg net, 440 x 391 x 195 mm: Net weight is 27.7 kg and gross 30.8 kg in a 552 x 508 x 290 mm carton; the IP21 chassis is air cooled for 0-40 °C operation.
Frequently Asked Questions
What is the output power of the IVPS10048P2G1?
10000VA and 8000W. The IVPS10048P2G1 is rated 10000VA apparent power and 8000W continuous, and carries a 20000VA surge for 5 seconds, which is why it is rated as capable of starting an electric motor. Peak efficiency is 90%.
What battery voltage and charge current does the IVPS10048P2G1 use?
48V nominal DC, charging at up to 80A and regulated across 0-80A. It starts from 46V, alarms at 46Vdc below 50% load or 44Vdc at 50% load and above, and shuts down at 43Vdc / 42Vdc. Lithium charging tops out at 61.0V; AGM boost is 57.6V and float 54.4V.
What are the dimensions and weight of the IVPS10048P2G1?
584 x 420 x 195 mm and 67.7 kg gross. Packaged it measures 670x470x355mm. The unit operates from 0°C~40°C and is stored between -15°C~60°C.
Can the IVPS10048P2G1 charge from a generator or an unstable grid?
90-280Vac is the accepted utility charging range, and the input waveform is sinusoidal from utility or generator. Nominal input is 220Vac at 50Hz/60Hz, transfer takes 15ms (typical), a 63A overcurrent protector guards the grid side, and the unit does not pass utility through without a battery connected.
What output power does the IVPS3524P1G1-LV deliver?
2.8 kW, single phase, and the same 2.8 kW stays available on the backup output. The waveform is a pure sine wave at 110-127 V and 50/60 Hz, regulated within 5%, and the unit carries twice rated load for 5 s to start motors.
What battery does the IVPS3524P1G1-LV need?
24 V. The bank works anywhere from 21 V to 31.5 V on the single battery input. AGM, flooded, Li-Ion and self-defined types are supported, charged in three stages - boost CC, boost CV, float - at up to 40 A with 28.8 V bulk and 27.2 V float. It starts at 23 V and talks to a BMS over RS485.
Will the IVPS3524P1G1-LV run on a weak 110 V supply or a generator?
80-140 V is the appliance-mode input window, so it holds on until 80 V and reconnects at 85 V; UPS mode uses 90-140 V. Input may be a sinusoidal utility or generator waveform at 50/60 Hz, and switching to battery takes 15 ms.
How much does the IVPS3524P1G1-LV weigh and what size is it?
27.7 kg net and 30.8 kg gross. The unit measures 440 x 391 x 195 mm and ships in a 552 x 508 x 290 mm carton. It is a low-frequency, transformer-based build rated IP21 with intelligent air cooling, for 0-40 °C operation and -15 to 60 °C storage.
What is the rated output power of the IVPS5048P1G1-LV?
It is rated at 4 kW of output power, 5 kVA apparent, on a single phase, and its backup rated output power is also 4 kW. The low-frequency, transformer-based design carries twice rated load for 5 seconds, and the unit is motor-start capable.
What battery does the IVPS5048P1G1-LV run on, and how fast does it charge?
Nominal DC input is 48 V, with a working battery range of 42-63 V and start-up at 46 V. Charging is three-stage - boost CC, boost CV, float - at up to 50 A, with 57.6 V bulk and 54.4 V float and a 61.0 V maximum. AGM, flooded, lithium-ion and self-defined profiles are selectable, and BMS data runs over RS485.