Felicity Solar Off-Grid Inverters IVPS10048P2G1/IVPS3524P1G1-LV/IVPS5048P1G1-LV/IVPS7548P2G1

A 48V inverter/charger holding 8000W continuous from a 10000VA rating, with split-phase 110/120Vac±5% output on HOT1-N or HOT2-N and 90% peak efficiency.

Models Covered: IVPS10048P2G1, IVPS3524P1G1-LV, IVPS5048P1G1-LV, IVPS7548P2G1

Manufacturer: Shenzhen Felicity Solar Technology Co., Ltd.

Application: The Felicity Solar IVPS10048P2G1 is a 48V off-grid inverter and charger rated 10000VA and 8000W, holding a 20000VA surge for 5 seconds and charging a battery bank at up to 80A. It gives split-phase 110/120Vac±5% between HOT1-N or HOT2-N, regulated to ±5%rms, and transfers between utility and battery in 15ms (typical). Utility charging accepts 90-280Vac, disconnecting at 170±7Vac (UPS) or 90±7Vac (APL) on the low side and 280±7Vac on the high side; output is a pure sine wave and synchronises with input voltage in line mode. Battery settings cover 57.6V boost and 54.4V float on AGM, 58.4V and 55.2V on flooded, and 61.0V maximum on lithium, starting from 46V and shutting down at 43Vdc below 50% load. Peak efficiency is 90%, a 63A overcurrent protector guards the grid side, and the unit does not pass utility through without a battery. It measures 584 x 420 x 195 mm, weighs 67.7 kg gross and runs from 0°C~40°C. We are an authorised Felicity Solar distributor and supply the IVPS10048P2G1 from our own stock; warranty 2 Years.

Models and prices

Technical Specifications

Technical Specifications
ParameterIVPS10048P2G1IVPS3524P1G1-LVIVPS5048P1G1-LVIVPS7548P2G1
Additional Specifications
Battery0₁
Power0₁
BMS communication24V model(default 27.0V) bm5 6 bmSRS485RS48524V model(default 27.0V) bm5 6 bmS
Capable of Starting ElectricYes
Max. Bypass Overload Current30A AC63A
Outputsplit-phase system, make sure no "PAL", 3P1, 3P2——For supporting three-phase system, make sure no
Output Frequency50Hz50/60 Hz50/60 Hz50Hz
Output voltage25.0V to 31.5V. Increment of
Power derating216-06 221
Terminal ConnectionHOT1-HOT2
Nominal Input Voltage220Vac
Low Line Re-connect AC Input Range180±7Vac (UPS) / 100±7Vac (APL)
High Line Re-connect270±7Vac
Max AC Input Voltage280Vrms140 V140 V280Vrms
Nominal Input Frequency50Hz/60Hz50/60 Hz50/60 Hz50Hz/60Hz
Low Line Frequency Disconnect40±1Hz
Low Line Frequency Re-connect42±1Hz
High Line Frequency Disconnect65±1Hz
High Line Frequency Re-connect63±1Hz
Line Mode Output WaveformSynchronize with input voltageSame As Input WaveformSame As Input WaveformSynchronize with input voltage
Pass Through Without BatteryNo
Overcurrent Protector (grid)63A
Split-Phase Output Voltage110/120Vac±5% (HOT1-N or HOT2-N)
Inverter Over-Load Protection (SMPS load)5s@≥150% load; 10s@105%~150% load
Capable of Starting Electric MotorYes
Output Short Circuit ProtectionYes
Min DC Starting Voltage46V
Lithium Charging Voltage (max)61.0V
Product Dimension584x420x195mm——494x420x195mm
Gross Weight67.7 kg30.8 kg35.05 kg38.2 kg
Electrical Data
Efficiency (Line mode)≥95%
Nominal Output Frequency (Hz)50±0.3Hz / 60±0.3Hz (adjustable)
Over Charge ProtectionYes
Low Battery Alarm46Vdc (load < 50%) / 44Vdc (load ≥ 50%)
High DC Input Alarm / Fault63Vdc±0.4V
AC Output
Rated Output Power (VA)10000VA——7500VA
Rated Output Power (W)8000W——6000W
Nominal Output Voltage220/240Vac±5% (HOT1-HOT2)
Output Voltage Regulation±5%rms5%5%±5%rms
Peak Efficiency90%
DC Input
Nominal DC Input Voltage48V24 V48 V48V
Electrical Characteristics
Input Voltage WaveformSinusoidal (utility or generator)
Low Line Disconnect170±7Vac (UPS) / 90±7Vac (APL)
High Line Disconnect280±7Vac
Over-Load ProtectionAir switch protectionOvercurrent ProtectorAir Switch ProtectionAir switch protection
Transfer Time (AC to DC)15ms (typical)
Transfer Time (DC to AC)15ms (typical) / 30ms (special)
Input Voltage Range (utility charge)90-280Vac
Max Charge Current80A——60A
Charge Current Regulation0-80A——0-60A
Charger Short Circuit63A
Output Voltage WaveformPure sine wavePure Sine WavePure Sine WavePure sine wave
Surge Rating20000VA for 5 seconds2*rated (5s)2*rated (5s)15000VA for 5 seconds
Low Battery Recovery47Vdc (load < 50%) / 46Vdc (load ≥ 50%)
Low DC Input Shut-down43Vdc (load < 50%) / 42Vdc (load ≥ 50%)
High DC Input Recovery62Vdc±0.4V
Boost Charging Voltage (AGM)57.6V
Float Charging Voltage (AGM)54.4V
Boost Charging Voltage (Flooded)58.4V
Float Charging Voltage (Flooded)55.2V
Self-Defined Charging Voltage (max)61.0V
Mechanical Data
Package Dimension670x470x355mm——607x540x290mm
Operating Conditions
Operating Temperature0°C~40°C
Storage Temperature-15°C~60°C-15 to 60 °C-15 to 60 °C-15°C~60°C
Performance & Electrical
AC Output Voltage110-127 V
AC Wiring ModeL-N
Backup Rated Output Power—2.8 kW4 kW—
Battery Inputs1
Battery TypeAGM, Flooded, Li-Ion, Self-Defined
Battery Voltage Range—21-31.5 V42-63 V—
Bulk Charging Voltage—28.8 V57.6 V—
Charge AlgorithmThree-Stage: Boost CC, Boost CV, Float
Float Charging Voltage—27.2 V54.4 V—
High DC Input Recovery Voltage—31 V62 V—
High Frequency Disconnect65 Hz
High Frequency Reconnect63 Hz
High Line Disconnect Voltage140 V
High Line Reconnect Voltage135 V
Input Voltage Range80-140 V
Input Voltage Range (Appliance Mode)80-140 V
Input Voltage Range (UPS Mode)90-140 V
Line Mode Efficiency>95%
Low DC Shutdown (>50% Load)—21 V42 V—
Low Frequency Disconnect40 Hz
Low Frequency Reconnect42 Hz
Low Line Disconnect (Appliance Mode)80 V
Low Line Disconnect (UPS Mode)90 V
Low Line Reconnect (Appliance Mode)85 V
Low Line Reconnect (UPS Mode)95 V
Low-Battery Recovery (>50% Load)—23 V46 V—
Max AC Charge Current—40 A50 A—
Max AC Pass-Through Current—50 A63 A—
Max Charging Current—40 A50 A—
Max Charging Voltage—31.5 V61.0 V—
Max Efficiency90%
Motor Start CapableYes
Nominal AC Input Voltage110-120 V
Overload Trip Time (>105% Load)10 s
Overload Trip Time (>150% Load)5 s
PhaseSingle Phase
ProtectionOver Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection
Rated Apparent Output Power—3.5 kVA5 kVA—
Rated Output Power—2.8 kW4 kW—
Short-Circuit Protection (Line Mode)—Overcurrent ProtectorAir Switch Protection—
Start-Up Voltage—23 V46 V—
Transfer Time15 ms
Build & Interfaces
Communication InterfaceRS232, RS485
DisplayLCD, LED
Net Weight—27.7 kg31.35 kg—
Package Dimensions—552 x 508 x 290 mm607 x 540 x 290 mm—
Parallel Capability—89—
TopologyLow-Frequency (transformer-based)
Operating Environment
CoolingIntelligent Air Cooling
IP RatingIP21
Operating Temperature Range0-40 °C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in the UAE

MarketUAE
Grid authority / regulatorDEWA, ADDC, SEWA
Quotation currencyAED
Support hours timezoneAsia/Dubai
Main citiesDubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

For prices, see Felicity Solar Systems: Prices in UAE. Store pickup — collect your order from our store in Dubai or Riyadh.

Key Features & Technical Highlights

  • 10000VA rated, 8000W continuous: Rated 10000VA and 8000W continuous from a 48V nominal DC input.
  • 20000VA surge for 5 seconds: Carries a 20000VA surge for 5 seconds and is rated to start electric motors.
  • 80A maximum charge current: Charges at up to 80A, regulated anywhere across 0-80A, with over-charge protection.
  • Split-phase 110/120Vac±5% output: Delivers split-phase 110/120Vac±5% on HOT1-N or HOT2-N from a 220Vac nominal input.
  • 15ms (typical) transfer time: Transfers in 15ms (typical) and charges from utility anywhere in the 90-280Vac range.
  • 584 x 420 x 195 mm, 67.7 kg gross: Measures 584 x 420 x 195 mm at 67.7 kg gross and operates from 0°C~40°C.
  • 2.8 kW at 110-127 V: Rated output is 2.8 kW single phase, with the same 2.8 kW held on the backup output as a pure sine wave regulated within 5%.
  • 80-140 V input window: Appliance mode accepts 80-140 V and only disconnects at 80 V, reconnecting at 85 V; UPS mode narrows the window to 90-140 V.
  • 40 A three-stage charging: Charges a 24 V bank operating from 21 V to 31.5 V at up to 40 A, holding 28.8 V bulk and 27.2 V float across AGM, flooded, Li-Ion and self-defined types.
  • 15 ms transfer, 2x surge: Transfer time is 15 ms and the unit carries twice rated load for 5 s, which is what starts a motor without stalling the output.
  • Eight units in parallel: Up to 8 units run in parallel, with an RS485 BMS link, RS232 and RS485 interfaces and an LCD plus LED display.
  • 27.7 kg net, 440 x 391 x 195 mm: Net weight is 27.7 kg and gross 30.8 kg in a 552 x 508 x 290 mm carton; the IP21 chassis is air cooled for 0-40 °C operation.

Frequently Asked Questions

What is the output power of the IVPS10048P2G1?

10000VA and 8000W. The IVPS10048P2G1 is rated 10000VA apparent power and 8000W continuous, and carries a 20000VA surge for 5 seconds, which is why it is rated as capable of starting an electric motor. Peak efficiency is 90%.

What battery voltage and charge current does the IVPS10048P2G1 use?

48V nominal DC, charging at up to 80A and regulated across 0-80A. It starts from 46V, alarms at 46Vdc below 50% load or 44Vdc at 50% load and above, and shuts down at 43Vdc / 42Vdc. Lithium charging tops out at 61.0V; AGM boost is 57.6V and float 54.4V.

What are the dimensions and weight of the IVPS10048P2G1?

584 x 420 x 195 mm and 67.7 kg gross. Packaged it measures 670x470x355mm. The unit operates from 0°C~40°C and is stored between -15°C~60°C.

Can the IVPS10048P2G1 charge from a generator or an unstable grid?

90-280Vac is the accepted utility charging range, and the input waveform is sinusoidal from utility or generator. Nominal input is 220Vac at 50Hz/60Hz, transfer takes 15ms (typical), a 63A overcurrent protector guards the grid side, and the unit does not pass utility through without a battery connected.

What output power does the IVPS3524P1G1-LV deliver?

2.8 kW, single phase, and the same 2.8 kW stays available on the backup output. The waveform is a pure sine wave at 110-127 V and 50/60 Hz, regulated within 5%, and the unit carries twice rated load for 5 s to start motors.

What battery does the IVPS3524P1G1-LV need?

24 V. The bank works anywhere from 21 V to 31.5 V on the single battery input. AGM, flooded, Li-Ion and self-defined types are supported, charged in three stages - boost CC, boost CV, float - at up to 40 A with 28.8 V bulk and 27.2 V float. It starts at 23 V and talks to a BMS over RS485.

Will the IVPS3524P1G1-LV run on a weak 110 V supply or a generator?

80-140 V is the appliance-mode input window, so it holds on until 80 V and reconnects at 85 V; UPS mode uses 90-140 V. Input may be a sinusoidal utility or generator waveform at 50/60 Hz, and switching to battery takes 15 ms.

How much does the IVPS3524P1G1-LV weigh and what size is it?

27.7 kg net and 30.8 kg gross. The unit measures 440 x 391 x 195 mm and ships in a 552 x 508 x 290 mm carton. It is a low-frequency, transformer-based build rated IP21 with intelligent air cooling, for 0-40 °C operation and -15 to 60 °C storage.

What is the rated output power of the IVPS5048P1G1-LV?

It is rated at 4 kW of output power, 5 kVA apparent, on a single phase, and its backup rated output power is also 4 kW. The low-frequency, transformer-based design carries twice rated load for 5 seconds, and the unit is motor-start capable.

What battery does the IVPS5048P1G1-LV run on, and how fast does it charge?

Nominal DC input is 48 V, with a working battery range of 42-63 V and start-up at 46 V. Charging is three-stage - boost CC, boost CV, float - at up to 50 A, with 57.6 V bulk and 54.4 V float and a 61.0 V maximum. AGM, flooded, lithium-ion and self-defined profiles are selectable, and BMS data runs over RS485.