InvertersModel IVPS5024
Felicity Solar IVPS5024 4kW Single-Phase Inverter / Charger
A 24 V low-frequency, transformer-based off-grid inverter-charger rated 5 kVA apparent and 4 kW real output. Motor-start capable, and up to six units run in parallel.
- Rated Output Power: 4 kW
- Max Efficiency: 90 %
- Battery Voltage Range: 21-31.5 V
- Phase: Single Phase
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: AED 165
- 2-year warranty
Felicity Solar IVPS5024 4kW Single-Phase Inverter / Charger features
24 V nominal battery input, working across 21-31.5 V and starting at 23 V
50 A maximum charging current, three-stage boost CC, boost CV and float (28.8 V bulk, 27.2 V float)
Low-frequency transformer topology: motor-start capable with a 2x rated surge for 5 seconds
15 ms transfer time, 90-280 V AC input window and 63 A pass-through current
Up to 6 units in parallel; IP21, 29.1 kg net, 494 x 420 x 195 mm
About the Felicity Solar IVPS5024 4kW Single-Phase Inverter / Charger
The Felicity Solar IVPS5024 is a single-phase off-grid inverter-charger rated 5 kVA apparent and 4 kW real output, drawing from a 24 V battery bank and producing a pure sine wave at 220 V, 50/60 Hz. A 50 A charger and low-frequency transformer topology make it a fit for motor-driven loads. Because the design is transformer-based, the unit is motor-start capable and carries a 2x rated surge for 5 seconds, so pumps and compressors start without nuisance tripping. AC input is accepted from 90 V to 280 V in appliance mode, with a tighter 170-280 V UPS window for sensitive electronics, and transfer takes 15 ms. Battery support covers AGM, flooded, lithium-ion and self-defined profiles, with RS485 BMS communication and a three-stage boost CC, boost CV and float algorithm working between 21 V and 31.5 V. Up to six units operate in parallel. The unit measures 494 x 420 x 195 mm, weighs 29.1 kg net, and is rated IP21 with intelligent air cooling. We are an authorised Felicity Solar distributor and supply the IVPS5024 from our own stock.
Specifications last updated 23 March 2026
Felicity Solar IVPS5024 4kW Single-Phase Inverter / Charger full specifications
Electrical(55)
| AC Output Voltage | 220 V |
|---|---|
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 4 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 21-31.5 V |
| Bulk Charging Voltage | 28.8 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 27.2 V |
| High DC Input Recovery Voltage | 31 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 280 V |
| High Line Reconnect Voltage | 270 V |
| Input Voltage Range | 90-280 V |
| Input Voltage Range (UPS Mode) | 170-280 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | >95 % |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (<50% Load) | 21.5 V |
| Low DC Shutdown (>50% Load) | 21 V |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 90 V |
| Low Line Disconnect (UPS Mode) | 170 V |
| Low Line Reconnect (Appliance Mode) | 100 V |
| Low Line Reconnect (UPS Mode) | 180 V |
| Low-Battery Recovery (<50% Load) | 23.5 V |
| Low-Battery Recovery (>50% Load) | 23 V |
|---|---|
| Max AC Charge Current | 50 A |
| Max AC Input Voltage | 280 V |
| Max AC Pass-Through Current | 63 A |
| Max Charging Current | 50 A |
| Max Charging Voltage | 31.5 V |
| Max Efficiency | 90 % |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 220 V |
| Nominal DC Input Voltage | 24 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Air Switch Protection |
| Overload Trip Time (>105% Load) | 10 s |
| Overload Trip Time (>150% Load) | 5 s |
| Pass-Through Without Battery | No |
| Phase | Single Phase |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| Rated Apparent Output Power | 5 kVA |
| Rated Output Power | 4 kW |
| Short-Circuit Protection (Line Mode) | Air Switch Protection |
| Start-Up Voltage | 23 V |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 15 ms |
Mechanical(8)
| BMS Communication | RS485 |
|---|---|
| Communication Interface | RS232 |
| Display | LCD, LED |
| Gross Weight | 32.5 kg |
| Net Weight | 29.1 kg |
| Package Dimensions | 607 x 540 x 290 mm |
| Parallel Capability | 6 |
| Topology | Low-Frequency (transformer-based) |
Environmental(4)
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | 0-40 °C |
| Storage Temperature | -15 to 60 °C |
Downloads & support
Troubleshooting & error codes
Looking up an error code on this FelicityESS IVPS/IVPM Series? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →Frequently Asked Questions
What is the output power of the Felicity Solar IVPS5024?
It is rated at 5 kVA apparent power and 4 kW real output, single phase at 220 V and 50/60 Hz, with a pure sine wave waveform. Backup rated output power is also 4 kW, and the unit tolerates twice its rated load as a surge for 5 seconds.
What battery voltage and battery types does the IVPS5024 support?
It runs on a 24 V nominal battery bank, operating between 21 V and 31.5 V and starting up at 23 V. It supports AGM, flooded, lithium-ion and self-defined profiles, with RS485 BMS communication and a three-stage charge algorithm at 28.8 V bulk and 27.2 V float, up to 50 A.
How quickly does it switch to battery, and what AC input does it accept?
Transfer time is 15 ms. AC input is accepted from 90 V to 280 V in appliance mode and from 170 V to 280 V in UPS mode, with up to 63 A of pass-through current. The IVPS5024 does not pass through utility power without a battery connected.
What are the physical specifications of the IVPS5024?
The unit measures 494 x 420 x 195 mm and weighs 29.1 kg net, 32.5 kg gross, packed at 607 x 540 x 290 mm. It is rated IP21 with intelligent air cooling, an LCD and LED display, and an operating temperature range of 0 to 40 C.