Felicity IVEM5048 3000VA Inverter
The Felicity IVEM5048 is an inverter with 3000VA 5000VA rated output. Every figure on this page is taken from the manufacturer's datasheet for the IVEM5048.
- Rated Output Power(VA): 3000VA 5000VA
- Rated Output Power(W): 3000W 5000W
- Nominal DC Input Voltage: 24V 48V
Overview
The Felicity IVEM5048 is an inverter with 3000VA 5000VA rated output. Every figure on this page is taken from the manufacturer's datasheet for the IVEM5048.
Full specifications
Electrical
| Rated Output Power(VA) | 3000VA 5000VA |
|---|---|
| Rated Output Power(W) | 3000W 5000W |
| Nominal DC Input Voltage | 24V 48V |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) |
| Efficiency(Line Mode) | >95% (Rated R load, battery full charged) |
| Pass Through Without Battery | Yes |
| Nominal Input Voltage | 230Vac |
| Input Voltage Range | 90-280Vac |
| Max. Charge Current | 100A |
| Over Charge Protection | Yes |
| Max. PV Open Circuit Voltage | 500V |
| Max. Input Power | 4000W 6000W |
| Max. Solar Charging Current | 100A 100A |
| Max. Charging Current(PV+Grid) | 100A 100A |
| Max. Input Current | 15A 20A |
| Min. Startup Voltage | 125V |
| Output Voltage Waveform | Pure sine wave |
| Nominal Output Voltage | 230Vac+5% |
| Nominal Output Frequency(Hz) | 50±0.3Hz/60Hz±0.3Hz(Adjustable) |
| Parallel capability | Yes, up to 12 units No |
| Peak Efficiency | 93% |
| Surge Rating | 2* rated power for 5s |
| Capable of Starting Electric | Yes |
| Output Short Circuit Protection | Yes |
Mechanical
| Net Weight(KG) | 9.1KG 11.2KG |
|---|---|
| Gross Weight(KG) | 10.8KG 13.2KG |
| Product Dimension (MM) | 395*295*129MM 415*320*129MM |
| Package Dimension (MM) | 472*372*202MM 494*399*202MM |
Environmental
| Operating Temperature | 0°C~55°C |
|---|
Related Products


AI100-5048 ESS
- Rated Output Power:5000VA
- Max. Solar Charging Current:100A

Felicity IVAM10048P1G1 10000 VA Off-Grid Inverter
- Battery Type:Lead-acid or Lithium-ion
- Battery Voltage Range(V):40-60

Felicity IVAM12048P1G1 12000 VA Off-Grid Inverter
- Battery Type:Lead-acid or Lithium-ion
- Battery Voltage Range(V):40-60
Related Articles
Felicity Battery Not Charging? Codes, Causes & Fixes
Felicity battery not charging? Below 0°C the BMS blocks the charge, a charge voltage under 57.6 V never fills the pack, and codes C01–C08 explain the rest.
Read: Felicity Battery Not Charging? Codes, Causes & Fixes →Felicity Inverter Error After a Power Cut? What It Means
A long outage drained the battery, the grid came back shaky, and now there is a code on the screen. What 04, C02, 27 and the grid-return alarms really mean.
Read: Felicity Inverter Error After a Power Cut? What It Means →Felicity Inverter Overheating? Error 18 & Heat Codes
Inverter cutting out on hot afternoons? Error 18, T-REX 35/F35, E-CHO E12/E13, MPPT 87 and battery C09 — the official Felicity heat codes and their fixes.
Read: Felicity Inverter Overheating? Error 18 & Heat Codes →