48 kW PV input
The IVGM30KHP3G2 accepts 48 kW of solar array against its 30 kW rated three-phase output.

A three-phase hybrid inverter that takes 48 kW of solar into a 30 kW rated output, peaking at 33 kW of AC and a maximum output current of 47.9 A.
In stock
The Felicity Solar IVGM30KHP3G2 is a three-phase hybrid inverter that accepts 48 kW of solar array against a 30 kW rated output, peaks at 33 kW of AC at a maximum 47.9 A, and holds a 30 kW backup rating with a 10 ms transfer time. That gap between 48 kW at the input and 33 kW at the output is what separates the IVGM30KHP3G2 from a three-phase unit of the same rated power. The array spreads over three MPPT trackers working a 150-850 V window at 36+36+36 A, up to 1000 V per string, with 99.9% tracking efficiency and a 180 V start-up. Storage sits on two LFP inputs from 160 to 800 V, charging and discharging at 50+50 A over RS485 and CAN to the pack BMS. Conversion peaks at 97.6% and holds 97% European efficiency, with THD under 3%. The IP65 wall-mounted body runs from -40 to 60 °C on smart cooling at 87.1 kg net, is certified to EN 62477-1, IEC 62109-1 and IEC 62109-2, and carries a 5 Years warranty. We are an authorised Felicity Solar distributor and supply the IVGM30KHP3G2 from our own stock.
Specifications last updated 7 August 2026
| AC Output Line Voltage | 190-480 V |
|---|---|
| AC Output Voltage | 110-277 V |
| AC Rated Output Current | 43.5 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Rated Output Power | 30 kW |
| Battery Inputs | 2 |
| Battery Type | LFP |
| Battery Voltage Range | 160-800 V |
| Charge Algorithm | Self-Adaption to BMS |
| European Efficiency | 97 % |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations |
| Ground Fault Current Monitoring | Yes |
| MPPT Efficiency | 99.9 % |
| MPPT Full-Load Voltage Range | 444-850 V |
| MPPT Trackers | 3 |
| MPPT Voltage Range | 150-850 V |
| Max AC Output Power | 33 kW |
| Max AC Pass-Through Current | 200 A |
| Max Charging Current | 50+50 A |
| Max Discharging Current | 50+50 A |
| Max Efficiency | 97.6 % |
| Max Output Current | 47.9 A |
| Max Output Overcurrent Protection | 144 A |
| Max PV Access Power | 60 kW |
| Max PV Input Current | 36+36+36 A |
| Max PV Input Power | 48 kW |
| Max PV Voltage | 1000 V |
| Max Short-Circuit Current | 55+55+55 A |
| Min DC Input Voltage | 150 V |
| Nominal AC Input Line Voltage | 190-480 V |
| Nominal AC Input Voltage | 110-277 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Overvoltage Category (AC) | III |
| Overvoltage Category (DC) | II |
| Phase | Three Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated Apparent Output Power | 30 kVA |
| Rated Output Power | 30 kW |
| Rated PV Input Voltage | 600 V |
| Start-Up Voltage | 180 V |
| Strings per MPPT | 2 |
| Surge Protection Level (AC) | II |
| Surge Rating | 1.5*rated (10s) |
| Total Harmonic Distortion | <3 % |
| Transfer Time | 10 ms |
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD Touch Screen |
| Gross Weight | 107.1 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | WiFi/GPRS |
| Net Weight | 87.1 kg |
| Package Dimensions | 1114 x 774 x 469 mm |
| Parallel Capability | 12 |
| Safety Standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Topology | Non-Isolated |
| Cooling | Smart Cooling |
|---|---|
| IP Rating | IP65 |
| Operating Altitude | 3000 (>2000 derating) m |
| Operating Temperature Range | -40 to 60 (>50 derating) °C |
| Relative Humidity | 0-95 (non-condensing) % |








Sana'a sits above 2,000 metres, and an inverter whose datasheet permits 2,000 m is not rated for the city at all. Here is the altitude row on 44 Felicity listings, model by model, and which ones cover your elevation.
Read: Which Solar Inverters Actually Work in Sana'a? →Twenty-five Felicity inverters are IP21 and every SCCM charge controller says indoor wall-mount. IP20, IP21 and IP31 are indoor ratings, and the first digit - the dust one - is the half nobody reads. Here is which listing carries which.
Read: Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean →An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →48 kW of PV input, spread over three MPPT trackers that work a 150-850 V window at 36+36+36 A, with 1000 V maximum per string and a 180 V start-up voltage.
30 kW is the rated output and 33 kW is the maximum AC output, delivered at up to 47.9 A on a 3L+N+PE three-phase connection at 110-277 V and 50/60 Hz.
160-800 V LFP packs, on either of two battery inputs, charging and discharging at 50+50 A with RS485 and CAN links to the pack BMS.
IP65 rated and wall-mounted, it runs from -40 to 60 °C with derating above 50 °C on smart cooling, up to 3000 m altitude; the warranty is 5 Years.