230V/400V Three phase Pure
sine wave inverter

Discover the Felicity Solar IVGM16KLP3G1 Inverter with robust specs: 872.5mm x 450mm x 299.7mm, 48.7kg, and operates from -40°C to 60°C.
Introducing the Felicity Solar IVGM16KLP3G1 Inverter, a powerhouse of efficiency and reliability. Designed to withstand extreme temperatures from -40°C to 60°C, this inverter is perfect for diverse environments. With a compact design and a net weight of 48.7kg, it ensures seamless integration into your solar energy system.
| MPPT Voltage Rang | 160~650V |
|---|---|
| Max. AC Input/Output Apparent Power | 17.6 KVA |
| Max. Continuous AC Passthrough (grid to load) | 70A |
| Max. Output Overcurrent Protection | 92A |
| Max. PV Input Power | 25.6 kW |
| Max. PV Input Voltage | 800V |
| Max. discharging current | 300 A |
| Max.AC Input/Output Current | 25.5 A |
| Max.charging current | 300 A |
| No. of MPP Trackers /No. of Strings MPP Tracker | 2/2+2 |
| Power Factor Adjustment Range | <3% |
| Rated Input/Output Grid Frequency/Range | 50/60 Hz |
| Rated Input/Output Voltage/Range | 220/380,230 |
| Total Current Harmonic Distortion THDi | 0.8( leading |
| Battery Type | Li-Ion / Lead-acid |
| Battery Voltage Range | 40-60 V |
| Max Charging / Discharging Current | 300A |
| Max PV Input Power | 25.6kW |
| Max PV Input Voltage | 800 V |
| Start-up Voltage | 160 V |
| MPPT Voltage Range | 160-650 V |
| Rated DC Input Voltage | 550 V |
| Full Load DC Voltage Range | 445V-800V |
| Max Operating PV Input Current | 36+36 A |
| Max Input Short-Circuit Current | 54+54 A |
| Number of MPPT / Strings per MPPT | 2/2+2 |
| Rated AC Input/Output Active Power | 16kW |
| Max AC Input/Output Apparent Power | 17.6kVA |
| Peak Power (Off-grid) | 2 Times of Rated Power, 10s |
| Rated AC Input/Output Current | 23.2A |
| Max AC Input/Output Current | 25.5A |
| Max Continuous AC Passthrough (Grid to Load) | 70A |
| Max Output Overcurrent Protection | 92A |
| Rated Input/Output Voltage Range | 220/380, 230/400Vac (-20% ~ +15%) |
| AC Wiring Mode | 3L+N+PE |
| Rated Grid Frequency Range | 50/60Hz (45-55Hz / 55-65Hz) |
| DC Polarity Reverse Connection Protection | Yes |
| AC Output Overcurrent Protection | Yes |
| AC Output Overvoltage Protection | Yes |
| AC Output Short Circuit Protection | Yes |
| Thermal Protection | Yes |
| DC Terminal Insulation Impedance Monitoring | Yes |
| DC Component Monitoring | Yes |
| Power Network Monitoring | Yes |
| Island Protection Monitoring | Yes |
| DC Input Switch | Yes |
| Overvoltage Load Drop Protection | Yes |
| Residual Current (RCD) Detection | Yes |
| Surge Protection Level | TYPE II (DC), TYPE II (AC) |
| Communication with BMS | RS485/CAN |
| Monitor Module | WiFi/4G |
| Net Weight | 48.7 kg |
|---|---|
| Gross Weight | 60.2 kg |
| Product Dimensions (W x H x D) | 750 x 450 x 268 mm |
| Package Dimensions | 889 x 566 x 397 mm |
| Protection Degree | IP65 |
| Grid Standards | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
|---|---|
| Safety / EMC Standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Warranty | 5 Years / 10 Years (extended option) |




Felicity battery not charging? Below 0°C the BMS blocks the charge, a charge voltage under 57.6 V never fills the pack, and codes C01–C08 explain the rest.
Read: Felicity Battery Not Charging? Codes, Causes & Fixes →A long outage drained the battery, the grid came back shaky, and now there is a code on the screen. What 04, C02, 27 and the grid-return alarms really mean.
Read: Felicity Inverter Error After a Power Cut? What It Means →Inverter cutting out on hot afternoons? Error 18, T-REX 35/F35, E-CHO E12/E13, MPPT 87 and battery C09 — the official Felicity heat codes and their fixes.
Read: Felicity Inverter Overheating? Error 18 & Heat Codes →The IVGM16KLP3G1 inverter is designed for high efficiency and reliable power conversion. It supports a wide range of input voltages and is optimized for maximum energy output.
The IVGM16KLP3G1 inverter is compatible with most solar panel systems. However, it is recommended to check the specific voltage and current requirements of your solar panels to ensure compatibility.
The inverter measures 872.5mm in height, 450mm in width, and 299.7mm in depth. It has a net weight of 48.7 kg and a gross weight of 60.2 kg.
The inverter requires a wire size of 12AWG and a cable size of 4mm². It should be installed in an environment within the ambient temperature range of -40°C to 60°C.