Felicity Solar IVGM16KLP3G1 16kW Three-Phase Hybrid Solar Inverter
The Felicity Solar IVGM16KLP3G1 is a 16 kW three-phase hybrid solar inverter rated 17.6 kVA apparent at 380-400 V, with 97.6% maximum efficiency. It takes 25.6 kW of PV across two MPPT trackers and charges a 40-60 V battery bank at up to 300 A.
- Rated Output Power: 16 kW
- Max Apparent Power: 17.6 kVA
- Max Efficiency: 97.6 %
- Max PV Input Power: 25.6 kW
In stock
Felicity Solar IVGM16KLP3G1 16kW Three-Phase Hybrid Solar Inverter features
About the Felicity Solar IVGM16KLP3G1 16kW Three-Phase Hybrid Solar Inverter
The Felicity Solar IVGM16KLP3G1 is a 16 kW three-phase hybrid solar inverter. It delivers 16 kW and 17.6 kVA of apparent power at 380-400 V, converts at up to 97.6% efficiency, accepts 25.6 kW of PV across two MPPT trackers and charges a 40-60 V battery bank at up to 300 A. Each tracker runs from 160 V to 650 V with 2+2 strings and 36+36 A of input current, a 550 V rated PV input and full-load tracking from 445 V to the 800 V ceiling. On the AC side it gives 23.2 A rated and 25.5 A maximum output current, 70 A of pass-through and twice rated power for 10 seconds, transferring to the full 16 kW of backup in 20 ms. Up to 10 units run in parallel. Two battery inputs take lead-acid or lithium over RS485 or CAN, with a charge algorithm that self-adapts to the BMS. The IP65 enclosure with smart cooling measures 750 x 450 x 268 mm and weighs 48.7 kg. We stock and ship the IVGM16KLP3G1 as an authorised Felicity Solar distributor.
Specifications last updated 23 March 2026
Felicity Solar IVGM16KLP3G1 16kW Three-Phase Hybrid Solar Inverter full specifications
Electrical
| AC Output Line Voltage | 380-400 V |
|---|---|
| AC Output Voltage | 220-230 V |
| AC Rated Output Current | 23.2 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Rated Output Power | 16 kW |
| Battery Inputs | 2 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| DC Switch | Yes |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Full-Load Voltage Range | 445-800 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 160-650 V |
| Max AC Input Current | 25.5 A |
| Max AC Pass-Through Current | 70 A |
| Max Apparent Power | 17.6 kVA |
| Max Charging Current | 300 A |
| Max Discharging Current | 300 A |
| Max Efficiency | 97.6 % |
| Max Output Current | 25.5 A |
| Max Output Overcurrent Protection | 92 A |
| Max PV Input Current | 36+36 A |
| Max PV Input Power | 25.6 kW |
| Max PV Voltage | 800 V |
| Max Short-Circuit Current | 54+54 A |
| Nominal AC Input Line Voltage | 380-400 V |
| Nominal AC Input Voltage | 220-230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Phase | Three Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated Apparent Output Power | 16 kVA |
| Rated Output Power | 16 kW |
| Rated PV Input Voltage | 550 V |
| Start-Up Voltage | 160 V |
| Strings per MPPT | 2+2 |
| Surge Protection Level (AC) | II |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3 % |
| Transfer Time | 20 ms |
Mechanical
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD Touch Screen |
| Gross Weight | 60.2 kg |
| Monitoring Module | WiFi/4G |
| Net Weight | 48.7 kg |
| Package Dimensions | 889 x 566 x 397 mm |
| Parallel Capability | 10 |
| Safety Standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Topology | Non-Isolated |
Environmental
| Cooling | Smart Cooling |
|---|---|
| IP Rating | IP65 |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
Certifications
- IEC 62109-1
- EN 62109-1
- IEC 62109-2
- EN 62109-2
Related Products

Felicity Solar IVGM15KLP3G1 15kW Three-Phase Hybrid Solar Inverter
- Rated Output Power:15 kW
- Max Apparent Power:16.5 kVA

Felicity Solar IVGM18KLP3G1 18kW Three-Phase Hybrid Solar Inverter
- Rated Output Power:18 kW
- Max Apparent Power:19.8 kVA

Felicity Solar IVGM14KLP3G1 14kW Three-Phase Hybrid Solar Inverter
- Rated Output Power:14 kW
- Max Apparent Power:15.4 kVA

Felicity Solar IVGM20KLP3G1 20kW Three-Phase Hybrid Solar Inverter
- Rated Output Power:20 kW
- Max Apparent Power:22 kVA

Felicity Solar IVGM12KLP3G1 12kW Three-Phase Hybrid Solar Inverter
- Rated Output Power:12 kW
- Max Apparent Power:13.2 kVA

Felicity Solar IVGM25KHP3G2 25kW Three-Phase Hybrid Solar Inverter
- Rated Output Power:25 kW
- Max Efficiency:97.6 %

Felicity Solar IVGM10KLP3G1 10kW Three-Phase Hybrid Solar Inverter
- Rated Output Power:10 kW
- Max Apparent Power:11 kVA

Felicity Solar IVGM29K9HP3G2 29.9kW Three-Phase Hybrid Solar Inverter
- Rated Output Power:29.9 kW
- Max Efficiency:97.6 %
Related Articles
Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean
Twenty-five Felicity inverters are IP21 and every SCCM charge controller says indoor wall-mount. IP20, IP21 and IP31 are indoor ratings, and the first digit - the dust one - is the half nobody reads. Here is which listing carries which.
Read: Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean →How to Run a Whole House on Solar in Khartoum
An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →Which Solar Inverters Actually Work in Sana'a?
Sana'a sits above 2,000 metres, and an inverter whose datasheet permits 2,000 m is not rated for the city at all. Here is the altitude row on 44 Felicity listings, model by model, and which ones cover your elevation.
Read: Which Solar Inverters Actually Work in Sana'a? →