Felicity Solar Hybrid Inverters 25-50 kW IVGM25KHP3G2 / IVGM29K9HP3G2 / IVGM30KHP3G2 / IVGM40KHP3G2 / IVGM50KHP3G2
A 25 kW three-phase hybrid inverter whose two 150-850 V MPPTs accept 40 kW of array, with 27.5 kW maximum AC output, 39.9 A maximum output current and 25 kW held on backup.
Models and prices
- IVGM25KHP3G2AED 9,200incl. VAT
- IVGM29K9HP3G2AED 10,950incl. VAT
- IVGM30KHP3G2AED 11,000incl. VAT
- IVGM40KHP3G2AED 14,700incl. VAT
- IVGM50KHP3G2AED 18,350incl. VAT
Technical Specifications
| Parameter | IVGM25KHP3G2 | IVGM29K9HP3G2 | IVGM30KHP3G2 | IVGM40KHP3G2 | IVGM50KHP3G2 |
|---|---|---|---|---|---|
| Performance & Electrical | |||||
| AC Output Line Voltage | 190-480 V | ||||
| AC Output Voltage | 110-277 V | ||||
| AC Rated Output Current | 36.3 A | 43.4 A | 43.5 A | 58 A | 72.5 A |
| AC Wiring Mode | 3L+N+PE | ||||
| Backup Rated Output Power | 25 kW | 29.9 kW | 30 kW | 40 kW | 50 kW |
| Battery Inputs | 2 | ||||
| Battery Type | LFP | ||||
| Battery Voltage Range | 160-800 V | ||||
| Charge Algorithm | Self-Adaption to BMS | ||||
| European Efficiency | 97% | ||||
| Grid Frequency Range (50 Hz) | 45-55 Hz | ||||
| Grid Frequency Range (60 Hz) | 55-65 Hz | ||||
| Grid Regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations | ||||
| Ground Fault Current Monitoring | Yes | ||||
| MPPT Efficiency | 99.9% | ||||
| MPPT Full-Load Voltage Range | 555-850 V | 443-850 V | 444-850 V | 444-850 V | 550-850 V |
| MPPT Trackers | 2 | 3 | 3 | 4 | 4 |
| MPPT Voltage Range | 150-850 V | ||||
| Max AC Output Power | 27.5 kW | 29.9 kW | 33 kW | 44 kW | 55 kW |
| Max AC Pass-Through Current | 200 A | ||||
| Max Charging Current | 50+50 A | ||||
| Max Discharging Current | 50+50 A | ||||
| Max Efficiency | 97.6% | ||||
| Max Output Current | 39.9 A | 43.4 A | 47.9 A | 63.8 A | 79.7 A |
| Max Output Overcurrent Protection | 144 A | 144 A | 144 A | 192 A | — |
| Max PV Access Power | 50 kW | 59.8 kW | 60 kW | 80 kW | 100 kW |
| Max PV Input Current | 36+36 A | 36+36+36 A | 36+36+36 A | 36+36+36+36 A | 36+36+36+36 A |
| Max PV Input Power | 40 kW | 47.84 kW | 48 kW | 64 kW | 80 kW |
| Max PV Voltage | 1000 V | ||||
| Max Short-Circuit Current | 55+55 A | 55+55+55 A | 55+55+55 A | 55+55+55+55 A | 55+55+55+55 A |
| Min DC Input Voltage | 150 V | ||||
| Nominal AC Input Line Voltage | 190-480 V | ||||
| Nominal AC Input Voltage | 110-277 V | ||||
| Nominal Input Frequency | 50/60 Hz | ||||
| Output Frequency | 50/60 Hz | ||||
| Output Short-Circuit Protection | Yes | ||||
| Overload Protection | Yes | ||||
| Overvoltage Category (AC) | III | ||||
| Overvoltage Category (DC) | II | ||||
| Phase | Three Phase | ||||
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||||
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection | ||||
| Rated Apparent Output Power | 25 kVA | 29.9 kVA | 30 kVA | 40 kVA | 50 kVA |
| Rated Output Power | 25 kW | 29.9 kW | 30 kW | 40 kW | 50 kW |
| Rated PV Input Voltage | 600 V | ||||
| Start-Up Voltage | 180 V | ||||
| Strings per MPPT | 2 | ||||
| Surge Protection Level (AC) | II | ||||
| Surge Protection Level (DC) | II | ||||
| Surge Rating | 1.5*rated (10s) | ||||
| Total Harmonic Distortion | <3% | ||||
| Transfer Time | 10 ms | ||||
| Build & Interfaces | |||||
| BMS Communication | RS485, CAN | ||||
| Communication Interface | RS232, RS485 | ||||
| Display | LCD Touch Screen | ||||
| Gross Weight | 107.1 kg | ||||
| Installation Style | Wall-Mounted | ||||
| Monitoring Module | WiFi/GPRS | ||||
| Net Weight | 87.1 kg | ||||
| Package Dimensions | 1114 x 774 x 469 mm | ||||
| Parallel Capability | 12 | ||||
| Safety Standard | EN 62477-1, IEC 62109-1, IEC 62109-2 | ||||
| Topology | Non-Isolated | ||||
| Operating Environment | |||||
| Cooling | Smart Cooling | ||||
| IP Rating | IP65 | ||||
| Operating Altitude | 3000 (>2000 derating) m | ||||
| Operating Temperature Range | -40 to 60 (>50 derating) °C | ||||
| Relative Humidity | 0-95 (non-condensing)% | ||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 40 kW of PV on a 25 kW inverter: Maximum PV input power on the IVGM25KHP3G2 is 40 kW, taken as 36+36 A across two MPP trackers at up to 1000 V.
- 27.5 kW maximum AC output: Rated at 25 kVA, the IVGM25KHP3G2 peaks at 27.5 kW of AC output and 39.9 A of maximum output current.
- 25 kW of backup rated power: Backup rated output power is the full 25 kW, picked up in a 10 ms transfer time with under 3% harmonic distortion.
- 160-800 V battery across two inputs: Two inputs take an LFP pack from 160 V to 800 V and charge or discharge at 50+50 A, talking RS485 or CAN to its BMS.
- 97.6% peak efficiency: European efficiency is 97% and MPPT efficiency 99.9% over a 150-850 V tracking window that starts at 180 V.
- IP65 from -40 to 60 °C: Smart cooling, 87.1 kg net, wall-mounted, and paralleled up to 12 units with 144 A output overcurrent protection.
- 29.9 kW and 29.9 kVA rated output: The IVGM29K9HP3G2 stops just short of 30 kW, on a three-phase 3L+N+PE connection at 110-277 V.
- 47.84 kW maximum PV input power: Three MPPT trackers cover a 150-850 V window at 36+36+36 A, up to a 1000 V PV ceiling.
- 43.4 A rated output current per phase: Output overcurrent protection sits at 144 A, with a surge rating of 1.5*rated (10s).
- 160-800 V LFP battery across two inputs: Each input charges and discharges at 50+50 A, with BMS communication over RS485 and CAN.
- The full 29.9 kW stays available on backup: Transfer takes 10 ms and total harmonic distortion stays below 3%.
- IP65 wall-mounted body rated -40 to 60 °C: Smart cooling, 3000 m operating altitude, 87.1 kg net, and up to 12 units in parallel.
Frequently Asked Questions
How much solar can the IVGM25KHP3G2 take?
40 kW. Maximum PV input power is 40 kW on a 25 kW inverter, drawn as 36+36 A across two MPP trackers that cover 150-850 V and accept up to 1000 V.
What is the maximum output of the IVGM25KHP3G2?
27.5 kW. Maximum AC output power is 27.5 kW above the 25 kVA rating, at up to 39.9 A of output current, with output overcurrent protection at 144 A.
Which battery works with the IVGM25KHP3G2?
160-800 V. An LFP pack anywhere in that range connects to either of the two battery inputs and charges or discharges at 50+50 A, over RS485 or CAN to its BMS.
Can the IVGM25KHP3G2 be installed outdoors?
IP65. The enclosure is IP65 and runs from -40 to 60 °C with derating above 50 °C, wall-mounted on smart cooling at 87.1 kg net.
How much solar can the IVGM29K9HP3G2 take?
47.84 kW is the maximum PV input power of the IVGM29K9HP3G2, tracked by 3 MPPTs over a 150-850 V window at 36+36+36 A, from a 180 V start-up and up to a 1000 V maximum PV voltage.
Is the IVGM29K9HP3G2 a 30 kW inverter?
29.9 kW is the rated output power, and 29.9 kVA the rated apparent power, so this model sits just below 30 kW rather than at it. Backup output holds the same 29.9 kW.
What battery does the IVGM29K9HP3G2 work with?
160-800 V is the battery voltage range, LFP chemistry, on two battery inputs that charge and discharge at 50+50 A, with BMS communication over RS485 and CAN.
Can the IVGM29K9HP3G2 be mounted outdoors, and what warranty comes with it?
IP65 is the enclosure rating, wall-mounted, with smart cooling and a -40 to 60 °C operating range that derates above 50 °C, up to 3000 m. We are an authorised Felicity Solar distributor and it carries a 5 Years warranty.
How much solar can the IVGM30KHP3G2 take?
48 kW of PV input, spread over three MPPT trackers that work a 150-850 V window at 36+36+36 A, with 1000 V maximum per string and a 180 V start-up voltage.
Why does the IVGM30KHP3G2 list both 30 kW and 33 kW?
30 kW is the rated output and 33 kW is the maximum AC output, delivered at up to 47.9 A on a 3L+N+PE three-phase connection at 110-277 V and 50/60 Hz.