Three-phase output
220/380 V through 277/480 V, ten grid configurations.

29.9 kW three-phase high-voltage hybrid solar inverter.
The Felicity Solar IVGM29K9HP3G2 is a three-phase hybrid inverter rated at 29.9 kW. It works with a high-voltage LFP battery over a 160-800 Vdc range on two battery inputs, tracks the array from 150 to 850 Vdc, and carries an IP65 enclosure rated from -40°C to 60°C with smart cooling — built for a rooftop or a yard, not a plant room.
| AC Input/Output Rated Current | 43. 4 A |
|---|---|
| Max. AC Input/Output Current | 47.9A |
| Max. AC Output Power | 29.9kW |
| Max. Charging Current | 50+50(A) |
| Max. DC Input Voltage | 1000Vdc |
| Max. Discharging Current | 50+50(A) |
| Max. Output Overcurrent Protection (A) | (A) |
| Peak Power (off-grid)(W) | power, 10S |
| Max. Output Overcurrent Protection | 144 A |
| Max. AC Input/Output Power | 29.9 kW |
| Rated AC Input/Output Power | 29.9 kW |
| No.of MPP Trackers | 3 |
| Full Load DC Voltage Range | 443~850Vdc |
| Installation Style | Wall-mounted |
| Monitor module | WiFi/GPRS |
| Communication with BMS | RS485,CAN |
| Altitude | 3000 m (> 2000 m derating) |
| Operating Temperature Range | -40 to 60 °C (> 50 °C derating) |
| Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Over Voltage Category | OVC II(DC), OVC III(AC) |
| Surge Protection Level | TYPE II(DC), TYPE II(AC) |
| MPPT Efficiency | 99.90% |
| Euro Efficiency | 97.00% |
| Max. Efficiency | 97.60% |
| DC Injection Current | <0.5% In |
| AC Wiring Mode | 3L+N+PE |
| Max. Continuous AC Passthrough (grid to load) | 200 A |
| Peak Power (off-grid) | 1.5 time of rated power, 10S |
| No.of Strings per MPP Tracker | 2 |
| Start-up Voltage | 180 Vd.c. |
| Number of battery input | 2 |
| Rated AC Output Power | 29.9kW |
| Max AC Output Power | 29.9kW |
| AC Output Rated Current | 43.4A |
| Max. AC Current | 43.4A |
| Max. DC Access Power | 59.8kW |
| Max. DC Input Power | 47.84kW |
| Full Load DC Voltage Range | 443~850Vdc |
| PV Input Current | 36+36+36 (A) |
| Max. PV Isc | 55+55+55 (A) |
| Number of MPP Trackers | 3 |
| Battery Type | LFP (LiFePO4) |
| Battery Voltage Range | 160~800Vdc |
| Max Charging Current | 50+50 A |
| Max Discharging Current | 50+50 A |
| Number of Battery Input | 2 |
| Max DC Input Voltage | 1000Vdc |
| Min. DC Input Voltage | 150Vdc |
| Start-up Voltage | 180Vdc |
| Rated DC Input Voltage | 600Vdc |
| MPPT Range | 150~850Vdc |
| Strings per MPP Tracker | 2 |
| Rated AC Voltage | 110V/190V, 115V/200V, 120V/208V, 127V/220V, 133V/230V, 200V/346V, 220V/380V, 230V/400V, 240V/415V, 277V/480V |
| Rated AC Frequency | 50 / 60 Hz (45~55Hz / 55~65Hz) |
| THDi | <3% at rated power |
| Power Factor | 0.8 leading to 0.8 lagging |
| Net Weight | 87.1 kg |
|---|---|
| Gross Weight | 107.1 kg |
| Product Dimension | 940*582*340 mm |
| Package Dimension | 1114*774*469 mm |
| Protection Degree | IP65 |
|---|---|
| Operating Temperature Range | -40 to 60°C (>50°C derating) |
| Humidity | 0~95% (no condensation) |
| Cooling | Smart Cooling |




Felicity battery not charging? Below 0°C the BMS blocks the charge, a charge voltage under 57.6 V never fills the pack, and codes C01–C08 explain the rest.
Read: Felicity Battery Not Charging? Codes, Causes & Fixes →A long outage drained the battery, the grid came back shaky, and now there is a code on the screen. What 04, C02, 27 and the grid-return alarms really mean.
Read: Felicity Inverter Error After a Power Cut? What It Means →Inverter cutting out on hot afternoons? Error 18, T-REX 35/F35, E-CHO E12/E13, MPPT 87 and battery C09 — the official Felicity heat codes and their fixes.
Read: Felicity Inverter Overheating? Error 18 & Heat Codes →Max DC access power is 59.8kW and max DC input power 47.84kW, over 3 MPP trackers with two strings each.
A high-voltage LFP pack anywhere from 160 to 800 Vdc, on either of its two battery inputs, charging and discharging at 50 A per input.
Yes. IP65, rated -40°C to 60°C with derating above 50°C, and smart cooling.