16kW of PV input across two MPPT trackers
That is twice the 8kW AC rating, carried as 27+27A over 2+2 strings up to a 500V maximum PV voltage.

An 8kW off-grid inverter that takes twice its own AC rating in solar: the IVAM8048P1G1 accepts 16kW of PV across two MPPTs and moves 190A in or out of a 48V bank.
In stock
The Felicity Solar IVAM8048P1G1 is a single-phase off-grid solar inverter rated 8kW and 8kVA at 230V, accepting up to 16kW of PV across two MPPT trackers and charging or discharging a 48V battery bank at up to 190A, with a maximum efficiency of 97.6%. That 16kW PV ceiling is twice the inverter's own AC rating, and it is what separates the IVAM8048P1G1 from other 8kW machines: 27+27A of PV input current over 2+2 strings, a 90-425V MPPT window that narrows to 200-425V at full load, 370V rated PV input, a 120V start-up and 500V maximum PV voltage. One battery input covers 40-60V, lead-acid or Li-Ion, the charge algorithm self-adapting to the pack BMS over RS485 or CAN. Output is a pure sine wave under 3% THD at 50/60Hz, 34.8A maximum, with twice rated power available for 10 seconds and 8kW of backup rated output power. The IP65 case runs from -40°C to 60°C with derating above 45°C on intelligent air cooling, weighs 21.4kg net and measures 594 x 385 x 203mm; six units run in parallel. Certified to IEC 62109-1, EN 62109-1, IEC 62109-2 and EN 62109-2. We are an authorised Felicity Solar distributor; warranty is 2 Years.
Specifications last updated 17 August 2026
| AC Output Voltage | 230 V |
|---|---|
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 8 kW |
| Battery Inputs | 1 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| DC Switch | Yes |
| Ground Fault Current Monitoring | Yes |
| MPPT Full-Load Voltage Range | 200-425 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 90-425 V |
| Max AC Output Power | 8 kW |
| Max AC Pass-Through Current | 50 A |
| Max Charge/Discharge Power | 8 kW |
| Max Charging Current | 190 A |
| Max Discharging Current | 190 A |
| Max Efficiency | 97.6 % |
| Max Output Current | 34.8 A |
| Max PV Input Current | 27+27 A |
| Max PV Input Power | 16 kW |
| Max PV Voltage | 500 V |
| Max Short-Circuit Current | 40+40 A |
| Nominal AC Input Voltage | 230 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Yes |
| Overvoltage Category (AC) | III |
| Overvoltage Category (DC) | II |
| PV Working Voltage Range | 90-500 V |
| Phase | Single Phase |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection |
| Rated Apparent Output Power | 8 kVA |
| Rated Output Power | 8 kW |
| Rated PV Input Voltage | 370 V |
| Start-Up Voltage | 120 V |
| Strings per MPPT | 2+2 |
| Surge Protection Level (AC) | II |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3 % |
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS485, CAN |
| Display | LCD, LED |
| Gross Weight | 25.4 kg |
| Monitoring Module | WiFi/LAN (optional) |
| Net Weight | 21.4 kg |
| Package Dimensions | 752 x 507 x 348 mm |
| Parallel Capability | 6 |
| Safety Standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Topology | Non-Isolated |
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP65 |
| Operating Temperature Range | -40 to 60 (>45 derating) °C |








Twenty-five Felicity inverters are IP21 and every SCCM charge controller says indoor wall-mount. IP20, IP21 and IP31 are indoor ratings, and the first digit - the dust one - is the half nobody reads. Here is which listing carries which.
Read: Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean →An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →Sana'a sits above 2,000 metres, and an inverter whose datasheet permits 2,000 m is not rated for the city at all. Here is the altitude row on 44 Felicity listings, model by model, and which ones cover your elevation.
Read: Which Solar Inverters Actually Work in Sana'a? →16kW of maximum PV input power, twice its own 8kW AC rating, across two MPPT trackers carrying 27+27A on 2+2 strings. Maximum PV voltage is 500V and rated PV input voltage is 370V, with tracking starting at 120V over a 90-425V window that narrows to 200-425V at full load.
48V nominal, over a 40-60V working range on a single battery input. Lead-acid and Li-Ion are both supported at up to 190A charge and 190A discharge, or 8kW of charge and discharge power, and the charge algorithm self-adapts to the pack BMS over RS485 or CAN.
8kW rated output power and 8kVA rated apparent output power at 230V single phase, with 34.8A maximum output current on a pure sine wave under 3% THD. Surge capability is twice rated power for 10 seconds, backup rated output power is 8kW, and six units can run in parallel.
IP65, with an operating range of -40°C to 60°C and derating above 45°C on intelligent air cooling. The unit itself measures 594 x 385 x 203mm and weighs 21.4kg net, while the shipping carton is 752 x 507 x 348mm at 25.4kg gross. Warranty is 2 Years.