5+5 kW of PV input across a 90-450 V MPPT window
Two solar inputs rated 5 kW each carry 20+20 A of current up to a 500 V maximum PV voltage, with tracking that starts at 100 V.

An 8 kW single-phase off-grid inverter that pairs 5+5 kW of PV input with a 150 A charge ceiling, so the IVEM8048-II fills a 48 V bank as hard from the AC input as it does from the array.
In stock
The Felicity Solar IVEM8048-II is an 8 kW single-phase off-grid inverter. It takes 5+5 kW of solar across a 90-450 V MPPT range, charges a 48 V bank at up to 150 A from the array or the AC input, and holds the load on a 230 V pure sine wave with a 50 ms transfer time. Charging headroom is the figure that defines this model: 150 A maximum charge current, matched by 150 A maximum AC charge current, into a 42-63 V battery window. The single tracker starts at 100 V, works to 450 V and tolerates 500 V maximum PV voltage on 20+20 A of input current. Boost charging holds 56.4 V, float settles at 54 V for AGM, Flooded, Li-Ion and Self-Defined banks, and RS485 carries the BMS link beside an LCD and built-in WiFi. Surge is twice the rated output for 5 s, regulation stays within 5%, and 6 units run in parallel. The high-frequency chassis is 23.7 kg net and 25.6 kg gross in a 712 x 582 x 259 mm carton, certified to IEC 62109-1, IEC 62109-2 and IEC 63027. Warranty is 2 Years. We are the authorised Felicity Solar distributor.
Specifications last updated 17 August 2026
| AC Output Voltage | 230 V |
|---|---|
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 8 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 42-63 V |
| Bulk Charging Voltage | 56.4 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 54 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 280 V |
| High Line Reconnect Voltage | 270 V |
| Input Voltage Range | 90-280 V |
| Input Voltage Range (UPS Mode) | 170-280 V |
| Low Frequency Disconnect | 40 Hz |
| Low Line Disconnect (Appliance Mode) | 90 V |
| Low Line Disconnect (UPS Mode) | 170 V |
| Low Line Reconnect (Appliance Mode) | 100 V |
| Low Line Reconnect (UPS Mode) | 180 V |
| MPPT Trackers | 1 |
| MPPT Voltage Range | 90-450 V |
| Max AC Charge Current | 150 A |
| Max AC Input Voltage | 280 V |
| Max AC Pass-Through Current | 63 A |
| Max Charging Current | 150 A |
| Max Efficiency | 93 % |
| Max PV Input Current | 20+20 A |
| Max PV Input Power | 5+5 kW |
| Max PV Voltage | 500 V |
| Max Solar Charging Current | 150 A |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 230 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Yes |
| Overload Trip Time (>105% Load) | 10.5 s |
| Overload Trip Time (>120% Load) | 7.5 s |
| Overload Trip Time (>150% Load) | 5.5 s |
| Overload Trip Time (>200% Load) | 0.2 s |
| PV Working Voltage Range | 90-450 V |
| Pass-Through Without Battery | Yes |
| Phase | Single Phase |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| Rated Apparent Output Power | 8 kVA |
| Rated Output Power | 8 kW |
| Start-Up Voltage | 100 V |
| Strings per MPPT | 2 |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 50 ms |
| BMS Communication | RS485 |
|---|---|
| Display | LCD |
| Gross Weight | 25.6 kg |
| Monitoring Module | Built-In WiFi |
| Net Weight | 23.7 kg |
| Package Dimensions | 712 x 582 x 259 mm |
| Parallel Capability | 6 |
| Safety Standard | IEC 62109-1, IEC 62109-2, IEC 63027 |
| Topology | High-Frequency |
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | -10 to 50 °C |
| Storage Temperature | -15 to 60 °C |
Looking up an error code on this FelicityESS IVEM8048-II? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →







An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →A long outage drained the battery, the grid came back shaky, and now there is a code on the screen. What 04, C02, 27 and the grid-return alarms really mean.
Read: Felicity Inverter Error After a Power Cut? What It Means →Compare Felicity 48V and 96V inverter systems. Learn when 96V battery banks make sense, the efficiency benefits, and how to choose for large off-grid setups.
Read: Felicity 48V vs 96V Inverter: When to Use Higher Battery Voltage →5+5 kW of PV input, carrying 20+20 A of maximum input current up to a 500 V maximum PV voltage. The single MPPT tracker works from 90 V to 450 V and starts at 100 V, so a string has to reach 100 V before the IVEM8048-II begins harvesting.
150 A is the maximum charge current, and the maximum AC charge current is 150 A as well, so a 48 V nominal bank on a 42-63 V window fills at the same ceiling from an AC source as it does from the array. Boost charging holds 56.4 V and float settles at 54 V.
1 battery input accepts AGM, Flooded, Li-Ion and Self-Defined banks at 48 V nominal, talking to the BMS over RS485, and up to 6 IVEM8048-II units can be run in parallel. An LCD and built-in WiFi report the state of the system.
2 Years. The IVEM8048-II is certified to IEC 62109-1, IEC 62109-2 and IEC 63027, rated IP21, and carries overload protection, over temperature protection and short circuit protection, with intelligent air cooling for service from -10 to 50 °C. We are the authorised Felicity Solar distributor.