IVPS7548
Discover Felicity Solar IVPS/IVPM Series Inverters with 2500VA, 2000W output, 220Vac voltage, and 170A max charging current.
- Rated Output Power (Va): 7500VA
- Rated Output Power (W): 6000W
Features
Overview
The Felicity Solar IVPS/IVPM Series Inverters are designed to deliver reliable power with a rated output of 2500VA and 2000W. With a nominal output voltage of 220Vac and a robust charging capacity of up to 170A, these inverters are ideal for efficient energy management.
Full specifications
Electrical
| Capable of Starting Electric | Yes |
|---|---|
| Efficiency(Line mode) | >95% (Rated R |
| Input Voltage Range | 90-280Vac |
| Max. AC Input Voltage | 280Vrms |
| Max. Bypass Overload Current | 30A AC63A |
| Over-Load Protection (SMPS load) | Air switch protection |
| Rated Output Power (VA) | 7500VA |
| Rated Output Power (W) | 6000W |
| Nominal DC Input Voltage | 48V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 220Vac |
| Low Line Disconnect | 170±7Vac (UPS) / 90±7Vac (APL) |
| Low Line Re-connect AC Input Range | 180±7Vac (UPS) / 100±7Vac (APL) |
| High Line Disconnect | 280±7Vac |
| High Line Re-connect | 270±7Vac |
| Max AC Input Voltage | 280Vrms |
| Nominal Input Frequency | 50Hz/60Hz |
| Low Line Frequency Disconnect | 40±1Hz |
| Low Line Frequency Re-connect | 42±1Hz |
| High Line Frequency Disconnect | 65±1Hz |
| High Line Frequency Re-connect | 63±1Hz |
| Efficiency (Line mode) | ≥95% (rated R load, battery fully charged) |
| Transfer Time (AC to DC) | 15ms (typical) |
| Transfer Time (DC to AC) | 15ms (typical) |
| Pass Through Without Battery | No |
| Max Bypass Overload Current | AC 63A |
| Input Voltage Range (utility charge) | 90~280Vac |
| Max Charge Current | 60A |
| Charge Current Regulation | 0A~60A |
| Charger Short Circuit | AC 63A |
| Over Charge Protection | Yes |
| Output Voltage Waveform | Pure sine wave |
| Nominal Output Voltage | 220Vac±5% |
| Nominal Output Frequency (Hz) | 50±0.3Hz / 60±0.3Hz (adjustable) |
| Output Voltage Regulation | ±5%rms |
| Peak Efficiency | 90% |
| Over-Load Protection | 5s@≥150% load; 10s@105%~150% load SMPS load |
| Surge Rating | 15000VA for 5 seconds |
| Capable of Starting Electric Motor | Yes |
| Output Short Circuit Protection | Yes |
| Cold Start Voltage | 46V |
| Low Battery Recovery | 47V (load < 50%) / 46V (load ≥ 50%) |
| Low DC Input Shut-down | 43V (load < 50%) / 42V (load ≥ 50%) |
| High DC Input Recovery | 62±0.4V |
| Boost Charging Voltage (AGM) | 57.6V |
| Float Charging Voltage (AGM) | 54.4V |
| Boost Charging Voltage (Flooded) | 58.4V |
| Float Charging Voltage (Flooded) | 55.2V |
| Self-Defined Charging Voltage (max) | 61.0V |
Mechanical
| Package Dimension | 607x540x290mm |
|---|
Environmental
| Operating temperature | 0°C-40°C |
|---|---|
| Storage temperature | -15°C~60°C |
Certifications
- CE
- ISO9001
Troubleshooting & error codes
Looking up an error code on this FelicityESS IVPS/IVPM Series? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →Related Products


AI100-5048 ESS
- Rated Output Power:5000VA
- Max. Solar Charging Current:100A

Felicity IVAM10048P1G1 10000 VA Off-Grid Inverter
- Battery Type:Lead-acid or Lithium-ion
- Battery Voltage Range(V):40-60

Felicity IVAM12048P1G1 12000 VA Off-Grid Inverter
- Battery Type:Lead-acid or Lithium-ion
- Battery Voltage Range(V):40-60
Related Articles
Felicity Battery Not Charging? Codes, Causes & Fixes
Felicity battery not charging? Below 0°C the BMS blocks the charge, a charge voltage under 57.6 V never fills the pack, and codes C01–C08 explain the rest.
Read: Felicity Battery Not Charging? Codes, Causes & Fixes →Felicity Inverter Error After a Power Cut? What It Means
A long outage drained the battery, the grid came back shaky, and now there is a code on the screen. What 04, C02, 27 and the grid-return alarms really mean.
Read: Felicity Inverter Error After a Power Cut? What It Means →Felicity Inverter Overheating? Error 18 & Heat Codes
Inverter cutting out on hot afternoons? Error 18, T-REX 35/F35, E-CHO E12/E13, MPPT 87 and battery C09 — the official Felicity heat codes and their fixes.
Read: Felicity Inverter Overheating? Error 18 & Heat Codes →