Felicity Solar Hybrid Inverters 16 kW IVGM16KLP3G1
The Felicity Solar IVGM16KLP3G1 is a 16 kW three-phase hybrid solar inverter rated 17.6 kVA apparent at 380-400 V, with 97.6% maximum efficiency. It takes 25.6 kW of PV across two MPPT trackers and charges a 40-60 V battery bank at up to 300 A.
Models and prices
- IVGM16KLP3G1AED 8,800incl. VAT
Technical Specifications
| Parameter | IVGM16KLP3G1 |
|---|---|
| Performance & Electrical | |
| AC Output Line Voltage | 380-400 V |
| AC Output Voltage | 220-230 V |
| AC Rated Output Current | 23.2 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Rated Output Power | 16 kW |
| Battery Inputs | 2 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| DC Switch | Yes |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Full-Load Voltage Range | 445-800 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 160-650 V |
| Max AC Input Current | 25.5 A |
| Max AC Pass-Through Current | 70 A |
| Max Apparent Power | 17.6 kVA |
| Max Charging Current | 300 A |
| Max Discharging Current | 300 A |
| Max Efficiency | 97.6% |
| Max Output Current | 25.5 A |
| Max Output Overcurrent Protection | 92 A |
| Max PV Input Current | 36+36 A |
| Max PV Input Power | 25.6 kW |
| Max PV Voltage | 800 V |
| Max Short-Circuit Current | 54+54 A |
| Nominal AC Input Line Voltage | 380-400 V |
| Nominal AC Input Voltage | 220-230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Phase | Three Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated Apparent Output Power | 16 kVA |
| Rated Output Power | 16 kW |
| Rated PV Input Voltage | 550 V |
| Start-Up Voltage | 160 V |
| Strings per MPPT | 2+2 |
| Surge Protection Level (AC) | II |
| Surge Protection Level (DC) | II |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3% |
| Transfer Time | 20 ms |
| Build & Interfaces | |
| BMS Communication | RS485, CAN |
| Communication Interface | RS232, RS485 |
| Display | LCD Touch Screen |
| Gross Weight | 60.2 kg |
| Monitoring Module | WiFi/4G |
| Net Weight | 48.7 kg |
| Package Dimensions | 889 x 566 x 397 mm |
| Parallel Capability | 10 |
| Safety Standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Topology | Non-Isolated |
| Operating Environment | |
| Cooling | Smart Cooling |
| IP Rating | IP65 |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 16 kW rated output and 17.6 kVA maximum apparent power, three-phase 380-400 V on 3L+N+PE wiring at 50/60 Hz
- 97.6% maximum efficiency with up to 25.6 kW of PV across two MPPT trackers, tracking 445-800 V at full load
- 160-650 V MPPT range, 2+2 strings, 36+36 A of PV input current (54+54 A short-circuit) and 160 V start-up
- Two battery inputs for a 40-60 V lead-acid or lithium bank, charging and discharging at up to 300 A over RS485 or CAN
- 23.2 A rated and 25.5 A maximum output current, 70 A AC pass-through, 92 A overcurrent protection and a 20 ms transfer to the full 16 kW of backup
- IP65 enclosure with smart cooling, LCD touch screen and WiFi/4G monitoring, rated -25 °C to 60 °C with derating above 45 °C
Frequently Asked Questions
How much power does the Felicity IVGM16KLP3G1 deliver?
The IVGM16KLP3G1 is rated 16 kW with 17.6 kVA maximum apparent power, delivered as three-phase 380-400 V through 3L+N+PE wiring at 50/60 Hz. Rated output current is 23.2 A and maximum output current 25.5 A, with 92 A output overcurrent protection and a surge to twice rated power for 10 seconds. Backup rated output power is the full 16 kW, reached in a 20 ms transfer.
How much solar PV can the IVGM16KLP3G1 take?
Up to 25.6 kW of PV, split across two MPPT trackers taking 2+2 strings. Each tracker works from 160 V to 650 V, with full-load tracking from 445 V to 800 V, an 800 V maximum PV voltage, 550 V rated PV input voltage and 36+36 A of input current (54+54 A short-circuit). Start-up voltage is 160 V.
Which batteries does the IVGM16KLP3G1 charge, and how fast?
It has two battery inputs for lead-acid or lithium-ion banks in the 40-60 V range, charging and discharging at up to 300 A. BMS communication runs over RS485 or CAN and the charge algorithm self-adapts to the BMS, so a compatible lithium pack sets its own charge profile. Power factor is settable across the 0.8 leading to 0.8 lagging range.
Can several IVGM16KLP3G1 units be paralleled, and where can it be installed?
Up to 10 units can run in parallel. The inverter is IP65-rated with smart cooling and operates from -25 °C to 60 °C, derating above 45 °C. It measures 750 x 450 x 268 mm and weighs 48.7 kg net (60.2 kg gross), and carries a DC switch, AFCI, ground fault current monitoring and type II surge protection on both DC and AC. Safety certification is to IEC 62109-1, EN 62109-1, IEC 62109-2 and EN 62109-2.