7.5+7.5 kW of PV input power
Two PV inputs carrying 27+27 A feed one MPPT that works from 90 to 450 V, up to a 500 V maximum PV voltage.

A 12 kVA single-phase off-grid inverter for 48 V systems: two PV inputs at 7.5+7.5 kW and 27+27 A, a 90-450 V MPPT window, 240 A charging, and a 26.8 kg high-frequency chassis with LCD and built-in WiFi.
In stock
The Felicity Solar IVEM12048-11 is a 12 kVA single-phase off-grid solar inverter for a 48 V battery bank. It takes 7.5+7.5 kW of PV at 27+27 A, charges at up to 240 A from solar or AC, delivers 12 kW of backup rated power at 230 V, and weighs 26.8 kg net. That 7.5+7.5 kW of PV input is the figure that sets the -11 apart; it feeds one MPPT working from 90 to 450 V, up to a 500 V maximum PV voltage. Charging is three-stage, 56.4 V boost and 54 V float across a 42-63 V bank, and the 240 A ceiling holds from the array or from the 90-280 V AC input, which transfers in 50 ms. Output is a pure sine wave at 230 V, 50/60 Hz on L+N+PE, regulated to 5%, with 2*rated (5s) surge and 93% maximum efficiency. The IP21 high-frequency chassis weighs 26.8 kg net, ships at 28.7 kg in a 726 x 594 x 258 mm carton, parallels to 6 units and is certified to IEC 62109-1 and IEC 62109-2. We are the authorised Felicity Solar distributor and supply it with a 2 Years warranty.
Specifications last updated 17 August 2026
| AC Output Voltage | 230 V |
|---|---|
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 12 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 42-63 V |
| Bulk Charging Voltage | 56.4 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 54 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 280 V |
| High Line Reconnect Voltage | 270 V |
| Input Voltage Range | 90-280 V |
| Input Voltage Range (UPS Mode) | 170-280 V |
| Low Frequency Disconnect | 40 Hz |
| Low Line Disconnect (Appliance Mode) | 90 V |
| Low Line Disconnect (UPS Mode) | 170 V |
| Low Line Reconnect (Appliance Mode) | 100 V |
| Low Line Reconnect (UPS Mode) | 180 V |
| MPPT Trackers | 1 |
| MPPT Voltage Range | 90-450 V |
| Max AC Charge Current | 240 A |
| Max AC Input Voltage | 280 V |
| Max AC Pass-Through Current | 63 A |
| Max Charging Current | 240 A |
| Max Efficiency | 93 % |
| Max PV Input Current | 27+27 A |
| Max PV Input Power | 7.5+7.5 kW |
| Max PV Voltage | 500 V |
| Max Solar Charging Current | 240 A |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 230 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Yes |
| Overload Trip Time (>105% Load) | 10.5 s |
| Overload Trip Time (>120% Load) | 7.5 s |
| Overload Trip Time (>150% Load) | 5.5 s |
| Overload Trip Time (>200% Load) | 0.2 s |
| PV Working Voltage Range | 90-450 V |
| Pass-Through Without Battery | Yes |
| Phase | Single Phase |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| Rated Apparent Output Power | 12 kVA |
| Rated Output Power | 12 kW |
| Start-Up Voltage | 100 V |
| Strings per MPPT | 2 |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 50 ms |
| BMS Communication | RS485 |
|---|---|
| Display | LCD |
| Gross Weight | 28.7 kg |
| Monitoring Module | Built-In WiFi |
| Net Weight | 26.8 kg |
| Package Dimensions | 726 x 594 x 258 mm |
| Parallel Capability | 6 |
| Safety Standard | IEC 62109-1, IEC 62109-2 |
| Topology | High-Frequency |
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | -10 to 50 °C |
| Storage Temperature | -15 to 60 °C |








Compare Felicity 48V and 96V inverter systems. Learn when 96V battery banks make sense, the efficiency benefits, and how to choose for large off-grid setups.
Read: Felicity 48V vs 96V Inverter: When to Use Higher Battery Voltage →An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →A long outage drained the battery, the grid came back shaky, and now there is a code on the screen. What 04, C02, 27 and the grid-return alarms really mean.
Read: Felicity Inverter Error After a Power Cut? What It Means →7.5+7.5 kW is the maximum PV input power of the IVEM12048-11, drawn through 27+27 A of PV input current. The single MPPT works across a 90-450 V window up to a 500 V maximum PV voltage, and start-up voltage is 100 V.
240 A is the maximum charging current, and AC charging reaches the same 240 A. The three-stage charger holds 56.4 V boost and 54 V float across a 42-63 V window at 48 V nominal, supports AGM, Flooded, Li-Ion and Self-Defined batteries on one battery input, and reaches the BMS over RS485.
12 kVA rated apparent power and 12 kW of backup rated power, as a pure sine wave at 230 V single phase, 50/60 Hz on L+N+PE, regulated to 5%. Surge is 2*rated (5s), transfer takes 50 ms when the 90-280 V AC input drops, and maximum efficiency is 93%.
26.8 kg net and 28.7 kg gross, in a 726 x 594 x 258 mm package. The IP21 high-frequency chassis uses intelligent air cooling, runs from -10 to 50 °C and stores from -15 to 60 °C, so it belongs indoors in a ventilated space, and up to 6 units run in parallel. We are the authorised Felicity Solar distributor and supply it with a 2 Years warranty.