InvertersModel IVGM50KHP3G2
Felicity Solar IVGM50KHP3G2 50kW Three-Phase Hybrid Solar Inverter
A 50 kW three-phase hybrid inverter for commercial and industrial sites, with 55 kW maximum AC output, four MPPT trackers taking 80 kW of PV, and a 160-800 V LFP battery window. Up to 12 units run in parallel.
- Rated Output Power: 50 kW
- Max Efficiency: 97.6 %
- Max PV Input Power: 80 kW
- Battery Voltage Range: 160-800 V
Models in the IVGM25KHP3G2 – IVGM125KHP3G1 family
What sets the IVGM50KHP3G2 apart from the other 8 models in the family: AC Output Line Voltage 190-480 V; AC Output Voltage 110-277 V; AC Rated Output Current 72.5 A; Backup Rated Output Power 50 kW; Battery Voltage Range 160-800 V; Grid Regulation NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations; MPPT Full-Load Voltage Range 550-850 V; MPPT Trackers 4.
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: free
- 2-year warranty
Felicity Solar IVGM50KHP3G2 50kW Three-Phase Hybrid Solar Inverter features
Four MPPT trackers with two strings each: 80 kW maximum PV input power, 1000 V maximum PV voltage, 36 A per tracker
97.6% maximum efficiency, 97% European efficiency and 99.9% MPPT tracking efficiency, with total harmonic distortion under 3%
Two LFP battery inputs across a 160-800 V high-voltage range, charging and discharging at 50+50 A with the BMS self-adapting over RS485 or CAN
Up to 12 units in parallel and 200 A maximum AC pass-through current, with a 10 ms transfer time and 1.5x rated surge for 10 s
IP65 wall-mounted enclosure with smart cooling, -40 to +60 C operation (derating above 50 C) and a 3000 m altitude rating
About the Felicity Solar IVGM50KHP3G2 50kW Three-Phase Hybrid Solar Inverter
The Felicity Solar IVGM50KHP3G2 is a 50 kW three-phase hybrid solar inverter built for commercial and industrial installations. It delivers 50 kW rated output and 55 kW maximum AC power on a 3L+N+PE connection at 190-480 V line voltage, accepts up to 80 kW of PV across four MPPT trackers, and peaks at 97.6% efficiency. Each of the four trackers carries two strings and 36 A, rated to 1000 V, so a large roof or ground array can be split across orientations and shading groups without extra combiner hardware. Two battery ports connect LFP packs over a high-voltage 160-800 V window and charge or discharge at 50+50 A, with the pack's own BMS setting the charge profile over RS485 or CAN. For plants beyond one unit, up to 12 inverters run in parallel, and 200 A of AC pass-through current backs the loads behind them. The IP65 wall-mounted enclosure, smart cooling, -40 to +60 C range and 3000 m altitude rating suit outdoor plant rooms. Supplied by an authorised Felicity Solar distributor.
Specifications last updated 23 March 2026
Felicity Solar IVGM50KHP3G2 50kW Three-Phase Hybrid Solar Inverter full specifications
Electrical(50)
| AC Output Line Voltage | 190-480 V |
|---|---|
| AC Output Voltage | 110-277 V |
| AC Rated Output Current | 72.5 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Rated Output Power | 50 kW |
| Battery Inputs | 2 |
| Battery Type | LFP |
| Battery Voltage Range | 160-800 V |
| Charge Algorithm | Self-Adaption to BMS |
| European Efficiency | 97 % |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations |
| Ground Fault Current Monitoring | Yes |
| MPPT Efficiency | 99.9 % |
| MPPT Full-Load Voltage Range | 550-850 V |
| MPPT Trackers | 4 |
| MPPT Voltage Range | 150-850 V |
| Max AC Output Power | 55 kW |
| Max AC Pass-Through Current | 200 A |
| Max Charging Current | 50+50 A |
| Max Discharging Current | 50+50 A |
| Max Efficiency | 97.6 % |
| Max Output Current | 79.7 A |
| Max PV Access Power | 100 kW |
| Max PV Input Current | 36+36+36+36 A |
|---|---|
| Max PV Input Power | 80 kW |
| Max PV Voltage | 1000 V |
| Max Short-Circuit Current | 55+55+55+55 A |
| Min DC Input Voltage | 150 V |
| Nominal AC Input Line Voltage | 190-480 V |
| Nominal AC Input Voltage | 110-277 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Overvoltage Category (AC) | III |
| Overvoltage Category (DC) | II |
| Phase | Three Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated Apparent Output Power | 50 kVA |
| Rated Output Power | 50 kW |
| Rated PV Input Voltage | 600 V |
| Start-Up Voltage | 180 V |
| Strings per MPPT | 2 |
| Surge Protection Level (AC) | II |
| Surge Rating | 1.5*rated (10s) |
| Total Harmonic Distortion | <3 % |
| Transfer Time | 10 ms |
Mechanical(11)
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD Touch Screen |
| Gross Weight | 107.1 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | WiFi/GPRS |
| Net Weight | 87.1 kg |
|---|---|
| Package Dimensions | 1114 x 774 x 469 mm |
| Parallel Capability | 12 |
| Safety Standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Topology | Non-Isolated |
Environmental(5)
| Cooling | Smart Cooling |
|---|---|
| IP Rating | IP65 |
| Operating Altitude | 3000 (>2000 derating) m |
| Operating Temperature Range | -40 to 60 (>50 derating) °C |
| Relative Humidity | 0-95 (non-condensing) % |
Certifications(3)
- EN 62477-1
- IEC 62109-1
- IEC 62109-2
Downloads & support
Frequently Asked Questions
What are the output ratings of the Felicity IVGM50KHP3G2?
It is a 50 kW three-phase inverter: 50 kW rated output power and 50 kVA rated apparent power, with 55 kW maximum AC output. Rated output current is 72.5 A and maximum output current 79.7 A, on a 3L+N+PE connection at 110-277 V phase voltage (190-480 V line) and 50/60 Hz. Power factor is adjustable from 0.8 leading to 0.8 lagging.
How much solar can the IVGM50KHP3G2 take, and across how many strings?
Maximum PV input power is 80 kW, with maximum PV access power of 100 kW. It has four MPPT trackers carrying two strings each, at 36 A per tracker and 1000 V maximum PV voltage. The MPPT range is 150-850 V, with a full-load window of 550-850 V, a 600 V rated PV input voltage and a 180 V start-up voltage.
Which batteries does the IVGM50KHP3G2 work with?
It has two battery inputs for LFP packs over a 160-800 V high-voltage range, charging and discharging at 50+50 A. The charge algorithm self-adapts to the battery BMS, which communicates over RS485 or CAN, so the pack sets its own charge profile rather than a fixed curve on the inverter.
Can several IVGM50KHP3G2 units be combined on one commercial site?
Yes. Up to 12 units run in parallel, and each unit passes through up to 200 A of AC current. The inverter supports grid codes including VDE 4105, G99, CEI 0-21, NRS 097-2-1 and EN 50549-1/-10, and is built to EN 62477-1, IEC 62109-1 and IEC 62109-2, with anti-islanding, residual current monitoring and insulation resistance detection.