40 kW of PV on a 25 kW inverter
Maximum PV input power on the IVGM25KHP3G2 is 40 kW, taken as 36+36 A across two MPP trackers at up to 1000 V.

InvertersModel IVGM25KHP3G2
A 25 kW three-phase hybrid inverter whose two 150-850 V MPPTs accept 40 kW of array, with 27.5 kW maximum AC output, 39.9 A maximum output current and 25 kW held on backup.
What sets the IVGM25KHP3G2 apart from the other 8 models in the family: AC Output Line Voltage 190-480 V; AC Output Voltage 110-277 V; AC Rated Output Current 36.3 A; Backup Rated Output Power 25 kW; Battery Voltage Range 160-800 V; Grid Regulation NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations; MPPT Full-Load Voltage Range 555-850 V; MPPT Trackers 2.
In stock
Maximum PV input power on the IVGM25KHP3G2 is 40 kW, taken as 36+36 A across two MPP trackers at up to 1000 V.
Rated at 25 kVA, the IVGM25KHP3G2 peaks at 27.5 kW of AC output and 39.9 A of maximum output current.
Backup rated output power is the full 25 kW, picked up in a 10 ms transfer time with under 3% harmonic distortion.
Two inputs take an LFP pack from 160 V to 800 V and charge or discharge at 50+50 A, talking RS485 or CAN to its BMS.
European efficiency is 97% and MPPT efficiency 99.9% over a 150-850 V tracking window that starts at 180 V.
Smart cooling, 87.1 kg net, wall-mounted, and paralleled up to 12 units with 144 A output overcurrent protection.
The Felicity Solar IVGM25KHP3G2 is a 25 kW three-phase hybrid inverter that accepts up to 40 kW of PV input power, delivers 27.5 kW of maximum AC output power and 39.9 A of maximum output current, and keeps the full 25 kW available as backup rated power. Peak efficiency is 97.6% and European efficiency 97%. Its two MPP trackers cover 150-850 V, nominal 600 V, starting at 180 V and taking 36+36 A at up to 1000 V with 99.9% tracking efficiency. Two battery inputs accept an LFP pack from 160 V to 800 V and charge or discharge at 50+50 A, coordinated with the pack BMS over RS485 or CAN. Output is 3L+N+PE at 110-277 V and 50/60 Hz with under 3% total harmonic distortion, a 10 ms transfer time and output overcurrent protection at 144 A. The IP65 enclosure runs from -40 to 60 °C on smart cooling, weighs 87.1 kg net, mounts on a wall and parallels to 12 units. Certified to IEC 62109-1, IEC 62109-2 and EN 62477-1. We are an authorised Felicity Solar distributor and supply the IVGM25KHP3G2 from our own stock. Warranty: 5 Years.
Specifications last updated 7 August 2026
| AC Output Line Voltage | 190-480 V |
|---|---|
| AC Output Voltage | 110-277 V |
| AC Rated Output Current | 36.3 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Rated Output Power | 25 kW |
| Battery Inputs | 2 |
| Battery Type | LFP |
| Battery Voltage Range | 160-800 V |
| Charge Algorithm | Self-Adaption to BMS |
| European Efficiency | 97 % |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations |
| Ground Fault Current Monitoring | Yes |
| MPPT Efficiency | 99.9 % |
| MPPT Full-Load Voltage Range | 555-850 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 150-850 V |
| Max AC Output Power | 27.5 kW |
| Max AC Pass-Through Current | 200 A |
| Max Charging Current | 50+50 A |
| Max Discharging Current | 50+50 A |
| Max Efficiency | 97.6 % |
| Max Output Current | 39.9 A |
| Max Output Overcurrent Protection | 144 A |
| Max PV Access Power | 50 kW |
| Max PV Input Current | 36+36 A |
|---|---|
| Max PV Input Power | 40 kW |
| Max PV Voltage | 1000 V |
| Max Short-Circuit Current | 55+55 A |
| Min DC Input Voltage | 150 V |
| Nominal AC Input Line Voltage | 190-480 V |
| Nominal AC Input Voltage | 110-277 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Overvoltage Category (AC) | III |
| Overvoltage Category (DC) | II |
| Phase | Three Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated Apparent Output Power | 25 kVA |
| Rated Output Power | 25 kW |
| Rated PV Input Voltage | 600 V |
| Start-Up Voltage | 180 V |
| Strings per MPPT | 2 |
| Surge Protection Level (AC) | II |
| Surge Rating | 1.5*rated (10s) |
| Total Harmonic Distortion | <3 % |
| Transfer Time | 10 ms |
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD Touch Screen |
| Gross Weight | 107.1 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | WiFi/GPRS |
| Net Weight | 87.1 kg |
|---|---|
| Package Dimensions | 1114 x 774 x 469 mm |
| Parallel Capability | 12 |
| Safety Standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Topology | Non-Isolated |
| Cooling | Smart Cooling |
|---|---|
| IP Rating | IP65 |
| Operating Altitude | 3000 (>2000 derating) m |
| Operating Temperature Range | -40 to 60 (>50 derating) °C |
| Relative Humidity | 0-95 (non-condensing) % |
40 kW. Maximum PV input power is 40 kW on a 25 kW inverter, drawn as 36+36 A across two MPP trackers that cover 150-850 V and accept up to 1000 V.
27.5 kW. Maximum AC output power is 27.5 kW above the 25 kVA rating, at up to 39.9 A of output current, with output overcurrent protection at 144 A.
160-800 V. An LFP pack anywhere in that range connects to either of the two battery inputs and charges or discharges at 50+50 A, over RS485 or CAN to its BMS.
IP65. The enclosure is IP65 and runs from -40 to 60 °C with derating above 50 °C, wall-mounted on smart cooling at 87.1 kg net.