Felicity Solar IVGM15KLP3G1 15kW Three-Phase Hybrid Solar Inverter
The Felicity Solar IVGM15KLP3G1 is a 15 kW three-phase hybrid inverter rated 16.5 kVA apparent, with 97.6% maximum efficiency. It takes 24 kW of PV across two MPPT trackers and charges a 40-60 V battery bank at up to 280 A.
- Rated Output Power: 15 kW
- Max Apparent Power: 16.5 kVA
- Max Efficiency: 97.6 %
- Max PV Input Power: 24 kW
Models in the IVGM10KLP3G1 – IVGM20KLP3G1 family
What sets the IVGM15KLP3G1 apart from the other 6 models in the family: AC Rated Output Current 21.8 A; Backup Rated Output Power 15 kW; MPPT Full-Load Voltage Range 416-800 V; Max AC Input Current 23.9 A; Max AC Pass-Through Current 70 A; Max Apparent Power 16.5 kVA; Max Charging Current 280 A; Max Discharging Current 280 A.
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: free
- 2-year warranty
Felicity Solar IVGM15KLP3G1 15kW Three-Phase Hybrid Solar Inverter features
97.6% maximum efficiency, with two MPPT trackers accepting up to 24 kW of PV at up to 800 V
160-650 V MPPT range, 2+2 strings and 36+36 A of PV input current, starting from 160 V
Two battery inputs for a 40-60 V lead-acid or lithium bank, charging and discharging at up to 280 A over RS485 or CAN
21.8 A rated output current, 23.9 A maximum, 70 A AC pass-through and a 20 ms transfer to backup at the full 15 kW
IP65 enclosure with smart cooling, LCD touch screen and WiFi/4G monitoring, rated -25 C to 60 C with derating above 45 C
About the Felicity Solar IVGM15KLP3G1 15kW Three-Phase Hybrid Solar Inverter
The Felicity Solar IVGM15KLP3G1 is a 15 kW three-phase hybrid inverter rated 15 kW / 16.5 kVA at 380-400 V, with 97.6% maximum efficiency. It accepts up to 24 kW of PV across two MPPT trackers and charges a 40-60 V battery bank at up to 280 A, delivering the full 15 kW on backup. Each MPPT tracks 160-650 V and takes 2+2 strings, with 36+36 A of PV input current, an 800 V ceiling, 550 V rated PV input voltage and full-load tracking from 416 V. On the AC side the inverter provides 21.8 A rated output current, 23.9 A maximum and 70 A of pass-through current, surging to twice rated power for 10 seconds. Backup transfer takes 20 ms and up to 10 units can be paralleled. Batteries connect through two inputs with RS485 or CAN BMS communication and a charge algorithm that self-adapts to the BMS, so lithium and lead-acid both work. An LCD touch screen, WiFi/4G monitoring, AFCI, a DC switch and an IP65 enclosure with smart cooling round out a unit safety-certified to IEC 62109-1 and IEC 62109-2. We supply it as an authorised Felicity Solar distributor.
Specifications last updated 23 March 2026
Felicity Solar IVGM15KLP3G1 15kW Three-Phase Hybrid Solar Inverter full specifications
Electrical(47)
| AC Output Line Voltage | 380-400 V |
|---|---|
| AC Output Voltage | 220-230 V |
| AC Rated Output Current | 21.8 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Rated Output Power | 15 kW |
| Battery Inputs | 2 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| DC Switch | Yes |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Full-Load Voltage Range | 416-800 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 160-650 V |
| Max AC Input Current | 23.9 A |
| Max AC Pass-Through Current | 70 A |
| Max Apparent Power | 16.5 kVA |
| Max Charging Current | 280 A |
| Max Discharging Current | 280 A |
| Max Efficiency | 97.6 % |
| Max Output Current | 23.9 A |
|---|---|
| Max Output Overcurrent Protection | 92 A |
| Max PV Input Current | 36+36 A |
| Max PV Input Power | 24 kW |
| Max PV Voltage | 800 V |
| Max Short-Circuit Current | 54+54 A |
| Nominal AC Input Line Voltage | 380-400 V |
| Nominal AC Input Voltage | 220-230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Phase | Three Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated Apparent Output Power | 15 kVA |
| Rated Output Power | 15 kW |
| Rated PV Input Voltage | 550 V |
| Start-Up Voltage | 160 V |
| Strings per MPPT | 2+2 |
| Surge Protection Level (AC) | II |
| Surge Rating | 2*rated (10s) |
| Transfer Time | 20 ms |
Mechanical(10)
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD Touch Screen |
| Gross Weight | 60.2 kg |
| Monitoring Module | WiFi/4G |
| Net Weight | 48.7 kg |
| Package Dimensions | 889 x 566 x 397 mm |
| Parallel Capability | 10 |
| Safety Standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Topology | Non-Isolated |
Environmental(3)
| Cooling | Smart Cooling |
|---|---|
| IP Rating | IP65 |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
Certifications(4)
- IEC 62109-1
- EN 62109-1
- IEC 62109-2
- EN 62109-2
Downloads & support
Frequently Asked Questions
What is the rated output of the Felicity IVGM15KLP3G1?
The IVGM15KLP3G1 is rated at 15 kW with 16.5 kVA maximum apparent power, delivered as three-phase 380-400 V through 3L+N+PE wiring at 50/60 Hz. Rated output current is 21.8 A and maximum output current 23.9 A, and the inverter surges to twice rated power for 10 seconds. Backup rated output power is also 15 kW.
How much solar can the IVGM15KLP3G1 handle?
Up to 24 kW of PV, split across two MPPT trackers taking 2+2 strings. Each tracker works from 160 V to 650 V, with full-load tracking from 416 V to 800 V, an 800 V maximum PV voltage, 550 V rated PV input voltage and 36+36 A of input current (54+54 A short-circuit). Start-up voltage is 160 V.
Which batteries does the IVGM15KLP3G1 support?
It has two battery inputs for lead-acid or lithium-ion banks in the 40-60 V range, charging and discharging at up to 280 A. BMS communication runs over RS485 or CAN, and the charge algorithm self-adapts to the BMS, so a compatible lithium pack sets its own charge profile.
Can several IVGM15KLP3G1 units run in parallel, and where can it be installed?
Up to 10 units can be paralleled. The inverter is IP65-rated with smart cooling and operates from -25 C to 60 C, derating above 45 C. It measures 750 x 450 x 268 mm and weighs 48.7 kg net (60.2 kg gross), and includes a DC switch, AFCI and ground fault current monitoring.